2 resultados para Microstructure fabrication
em Illinois Digital Environment for Access to Learning and Scholarship Repository
Resumo:
The engineering of liquid behavior on surfaces is important for infrastructure, transportation, manufacturing, and sensing. Surfaces can be rendered superhydrophobic by microstructuring, and superhydrophobic devices could lead to practical corrosion inhibition, self-cleaning, fluid flow control, and surface drag reduction. To more fully understand how liquid interacts with microstructured surfaces, this dissertation introduces a direct method for determining droplet solid-liquid-vapor interfacial geometry on microstructured surfaces. The technique performs metrology on molten metal droplets deposited onto microstructured surfaces and then frozen. Unlike other techniques, this visualization technique can be used on large areas of curved and opaque microstructured surfaces to determine contact line. This dissertation also presents measurements and models for how curvature and flexing of microstructured polymers affects hydrophobicity. Increasing curvature of microstructured surfaces leads to decreased slide angle for liquid droplets suspended on the surface asperities. For a surface with regularly spaced asperities, as curvature becomes more positive, droplets suspended on the tops of asperities are suspended on fewer asperities. Curvature affects superhydrophobicity because microscopic curvature changes solid-liquid interaction, pitch is altered, and curvature changes the shape of the three phase contact line. This dissertation presents a model of droplet interactions with curved microstructured surfaces that can be used to design microstructure geometries that maintain the suspension of a droplet when curved surfaces are covered with microstructured polymers. Controlling droplet dynamics could improve microfluidic devices and the shedding of liquids from expensive equipment, preventing corrosion and detrimental performance. This dissertation demonstrates redirection of dynamic droplet spray with anisotropic microstructures. Superhydrophobic microstructured surfaces can be economically fabricated using metal embossing masters, so this dissertation describes casting-based microfabrication of metal microstructures and nanostructures. Low melting temperature metal was cast into flexible silicone molds which were themselves cast from microfabricated silicon templates. The flexibility of the silicone mold permits casting of curved surfaces, which this dissertation demonstrates by fabricating a cylindrical metal roller with microstructures. The metal microstructures can be in turn used as a reusable molding tool. This dissertation also describes an industrial investment casting process to produce aluminum molds having integrated microstructures. Unlike conventional micromolding tools, the aluminum mold was large and had complex curved surfaces. The aluminum was cast into curved microstructured ceramic molds which were themselves cast from curved microstructured rubber. Many structures were successfully cast into the aluminum with excellent replication fidelity, including circular, square, and triangular holes. This dissertation demonstrates molding of large, curved surfaces having surface microstructures using the aluminum mold. This work contributes a more full understanding of the phenomenon of superhydrophobicity and techniques for the economic fabrication of superhydrophobic microstructures.
Resumo:
Improvements to the current state of the art in microfabricated cantilevers are investigated in order to realize enhanced functionality and increased versatility for use in ultrafast electrophoretic molecular sorting and delivery. Design rationale and fabrication process flow are described for six types of electro-thermal microcantilevers. Devices have been tailored for the process of separating mixtures of heterogeneous molecules into discrete detectable bands based on electrophoretic mobility, and delivering them to a conductive substrate using electric fields. Four device types include integrated heating elements capable of warming samples to catalyze reactions or cleaning the device for reuse. Similar devices have been shown to be capable of targeting temperatures between ambient conditions and the melting point of silicon, to within 0.1˚C precision or better. All microcantilevers types are equipped with a highly doped conductive silicon tip capable of interacting with a conductive substrate to deliver molecules under the presence of an electric field. Devices are equipped with additional electrodes to aid in sorting molecules on the surface of the probe end. Two designs contain two legs and one additional sorting electrode while four designs contain three legs and have two sorting electrodes. Devices having two sorting electrodes are designed to be capable of sorting three or more molecular species, a distinctive advancement in the state of the art. A detailed process flow of the fabrication process for all six electro-thermal cantilever designs are explained in detail.