3 resultados para specimen shape effect
em Helda - Digital Repository of University of Helsinki
Resumo:
Goals This study aims to map the effect of interrogative function on the intonation of spontaneous and read Finnish. Earlier research shows that the most prominent feature in Finnish question intonation is an appeal to the listener. Question word questions typically start with a high peak which is followed by falling intonation. In yes/no questions, F0 remains on a high level until the word carrying sentence stress and then falls. Final rises are mainly found in intonation clichés such as "Ai mitä?" ("What?") These earlier results are based on read speech and enacted dialogues. In this study, questions and statements found in spontaneous dialogues were compared. These utterances were also compared with read versions of the same utterances. Fundamental frequency values were compared using a mixed model. Contours were also grouped using auditory and visual inspection. Thus it was possible to compare frequencies of contour types according to utterance type and speech style. The position of questions in the F0 distribution of the whole material was also investigated in this study. Method The material consisted of four spontaneous dialogues and their read versions. The speakers were young adults from the Helsinki metropolitan area, four females and four males. The whole material was first divided into broad dialogue function categories arising from the material and F0 curves were calculated for each category. After this, 277 questions and 244 statements were selected for closer inspection. Values reflecting F0 distribution and contour shape were measured from the F0 contours of these utterances. A mixed model was used to analyse the differences. Utterance type, question type, speech style and speaker gender were used as fixed effects. The frequencies of F0 contour types were compared using a Chi square test. Additional material in this study came from eight young female speakers in central Finland. Results and conclusions In the mixed model analysis, significant differences were found both between questions and statements and between spontaneous and read speech. Generally, utterance type affected the variables reflecting contour type while speech style affected the variables reflecting F0 distribution. The effect of question type was not clearly visible. In read speech the contours resembled earlier results more closely. Speakers had different strategies in differentiating between questions and statements. In the whole material, F0 was slightly higher in questions than in statements. The effect of dialectal background could be seen in the contour types. The results show that interrogative function affects intonation in both spontaneous and read Finnish.
Resumo:
This paper presents results from a study on the production of Finnish prosody. The effect of word order and the tonal shape in the production of Finnish prosody was studied as produced by 8 native Finnish speakers. Predictions formulated with regard to results from an earlier study pertaining to the perception of promi- nence were tested. These predictions had to do with the tonal shape of the utterances in the form of a flat hat pattern and the effect of word order on the so called top-line declination within an adver- bial phrase in the utterances. The results from the experiment give support to the following claims: the temporal domain of prosodic focus is the whole utterance, word order reversal from unmarked to marked has an effect on the production of prosody, and the pro- duction of the tonal aspects of focus in Finnish follows a basic flat hat pattern. That is the prominence of a word can be produced by an f 0 rise or a fall, depending on the location of the word in an utterance. The basic accentual shape of a Finnish word is then not a pointed rise/fall hat shape as claimed before since it can vary depending on the syllable structure and the position within an ut- terance.
Resumo:
Generation of raw materials for dry powder inhalers by different size reduction methods can be expected to influence physical and chemical properties of the powders. This can cause differences in particle size, size distribution, shape, crystalline properties, surface texture and energy. These physical properties of powders influence the behaviour of particles before and after inhalation. Materials with an amorphous surface have different surface energy compared to materials with crystalline surface. This can affect the adhesion and cohesion of particles. Changes in the surface nature of the drug particles results in a change in product performance. By stabilization of the raw materials the amorphous surfaces are converted into crystalline surfaces. The primary aim of the study was to investigate the influence of the surface properties of the inhalation particles on the quality of the product. The quality of the inhalation product is evaluated by measuring the fine particle dose (FPD). FDP is the total dose of particles with aerodynamic diameters smaller than 5,0 μm. The secondary aim of this study was to achieve the target level of the FPD and the stability of the FPD. This study was also used to evaluate the importance of the stabilization of the inhalation powders. The study included manufacturing and analysing drug substance 200 μg/dose inhalation powder batches using non-stabilized or stabilized raw materials. The inhaler formulation consisted of micronized drug substance, lactose <100μm and micronized lactose <10μm. The inhaler device was Easyhaler®. Stabilization of the raw materials was done in different relative humidity, temperature and time. Surface properties of the raw materials were studied by dynamic vapour sorption, scanning electron microscopy and three-point nitrogen adsorption technique. Particle size was studied by laser diffraction particle size analyzer. Aerodynamic particle size distribution from inhalers was measured by new generation impactor. Stabilization of all three raw materials was successful. A clear difference between nonstabilized and stabilized raw materials was achieved for drug substance and lactose <10μm. However for lactose <100μm the difference wasn’t as clear as wanted. The surface of the non-stabilized drug substance was more irregular and the particles had more roughness on the surface compared to the stabilized drug substances particles surface. The surface of the stabilized drug particles was more regular and smoother than non-stabilized. Even though a good difference between stabilized and non-stabilized raw materials was achieved, a clear evidence of the effect of the surface properties of the inhalation particles on the quality of the product was not observed. Stabilization of the raw materials didn’t lead to a higher FPD. Possible explanations for the unexpected result might be too rough conditions in the stabilization of the drug substance or smaller than wanted difference in the degree of stabilization of the main component of the product <100μm. Despite positive effects on the quality of the product were not seen there appears to be some evidence that stabilized drug substance results in smaller particle size of dry powder inhalers.