13 resultados para solvent extraction

em Helda - Digital Repository of University of Helsinki


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pressurised hot water extraction (PHWE) exploits the unique temperature-dependent solvent properties of water minimising the use of harmful organic solvents. Water is environmentally friendly, cheap and easily available extraction medium. The effects of temperature, pressure and extraction time in PHWE have often been studied, but here the emphasis was on other parameters important for the extraction, most notably the dimensions of the extraction vessel and the stability and solubility of the analytes to be extracted. Non-linear data analysis and self-organising maps were employed in the data analysis to obtain correlations between the parameters studied, recoveries and relative errors. First, pressurised hot water extraction (PHWE) was combined on-line with liquid chromatography-gas chromatography (LC-GC), and the system was applied to the extraction and analysis of polycyclic aromatic hydrocarbons (PAHs) in sediment. The method is of superior sensitivity compared with the traditional methods, and only a small 10 mg sample was required for analysis. The commercial extraction vessels were replaced by laboratory-made stainless steel vessels because of some problems that arose. The performance of the laboratory-made vessels was comparable to that of the commercial ones. In an investigation of the effect of thermal desorption in PHWE, it was found that at lower temperatures (200ºC and 250ºC) the effect of thermal desorption is smaller than the effect of the solvating property of hot water. At 300ºC, however, thermal desorption is the main mechanism. The effect of the geometry of the extraction vessel on recoveries was studied with five specially constructed extraction vessels. In addition to the extraction vessel geometry, the sediment packing style and the direction of water flow through the vessel were investigated. The geometry of the vessel was found to have only minor effect on the recoveries, and the same was true of the sediment packing style and the direction of water flow through the vessel. These are good results because these parameters do not have to be carefully optimised before the start of extractions. Liquid-liquid extraction (LLE) and solid-phase extraction (SPE) were compared as trapping techniques for PHWE. LLE was more robust than SPE and it provided better recoveries and repeatabilities than did SPE. Problems related to blocking of the Tenax trap and unrepeatable trapping of the analytes were encountered in SPE. Thus, although LLE is more labour intensive, it can be recommended over SPE. The stabilities of the PAHs in aqueous solutions were measured using a batch-type reaction vessel. Degradation was observed at 300ºC even with the shortest heating time. Ketones and quinones and other oxidation products were observed. Although the conditions of the stability studies differed considerably from the extraction conditions in PHWE, the results indicate that the risk of analyte degradation must be taken into account in PHWE. The aqueous solubilities of acenaphthene, anthracene and pyrene were measured, first below and then above the melting point of the analytes. Measurements below the melting point were made to check that the equipment was working, and the results were compared with those obtained earlier. Good agreement was found between the measured and literature values. A new saturation cell was constructed for the solubility measurements above the melting point of the analytes because the flow-through saturation cell could not be used above the melting point. An exponential relationship was found between the solubilities measured for pyrene and anthracene and temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis discusses the use of sub- and supercritical fluids as the medium in extraction and chromatography. Super- and subcritical extraction was used to separate essential oils from herbal plant Angelica archangelica. The effect of extraction parameters was studied and sensory analyses of the extracts were done by an expert panel. The results of the sensory analyses were compared to the analytically determined contents of the extracts. Sub- and supercritical fluid chromatography (SFC) was used to separate and purify high-value pharmaceuticals. Chiral SFC was used to separate the enantiomers of racemic mixtures of pharmaceutical compounds. Very low (cryogenic) temperatures were applied to substantially enhance the separation efficiency of chiral SFC. The thermodynamic aspects affecting the resolving ability of chiral stationary phases are briefly reviewed. The process production rate which is a key factor in industrial chromatography was optimized by empirical multivariate methods. General linear model was used to optimize the separation of omega-3 fatty acid ethyl esters from esterized fish oil by using reversed-phase SFC. Chiral separation of racemic mixtures of guaifenesin and ferulic acid dimer ethyl ester was optimized by using response surface method with three variables per time. It was found that by optimizing four variables (temperature, load, flowate and modifier content) the production rate of the chiral resolution of racemic guaifenesin by cryogenic SFC could be increased severalfold compared to published results of similar application. A novel pressure-compensated design of industrial high pressure chromatographic column was introduced, using the technology developed in building the deep-sea submersibles (Mir 1 and 2). A demonstration SFC plant was built and the immunosuppressant drug cyclosporine A was purified to meet the requirements of US Pharmacopoeia. A smaller semi-pilot size column with similar design was used for cryogenic chiral separation of aromatase inhibitor Finrozole for use in its development phase 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantification and characterisation of soil phosphorus (P) is of agricultural and environmental importance and different extraction methods are widely used to asses the bioavailability of P and to characterize soil P reserves. However, the large variety of extractants, pre-treatments and sample preparation procedures complicate the comparison of published results. In order to improve our understanding of the behaviour and cycling of P in soil, it is crucial to know the scientific relevance of the methods used for various purposes. The knowledge of the factors affecting the analytical outcome is a prerequisite for justified interpretation of the results. The aim of this thesis was to study the effects of sample preparation procedures on soil P and to determine the dependence of the recovered P pool on the chemical nature of extractants. Sampling is a critical step in soil testing and sampling strategy is dependent on the land-use history and the purpose of sampling. This study revealed that pre-treatments changed soil properties and air-drying was found to affect soil P, particularly extractable organic P, by disrupting organic matter. This was evidenced by an increase in the water-extractable small-sized (<0.2 µm) P that, at least partly, took place at the expense of the large-sized (>0.2 µm) P. However, freezing induced only insignificant changes and thus, freezing can be taken to be a suitable method for storing soils from the boreal zone that naturally undergo periodic freezing. The results demonstrated that chemical nature of the extractant affects its sensitivity to detect changes in soil P solubility. Buffered extractants obscured the alterations in P solubility induced by pH changes; however, water extraction, though sensitive to physicochemical changes, can be used to reveal short term changes in soil P solubility. As for the organic P, the analysis was found to be sensitive to the sample preparation procedures: filtering may leave a large proportion of extractable organic P undetected, whereas the outcome of centrifugation was found to be affected by the ionic strength of the extractant. Widely used sequential fractionation procedures proved to be able to detect land-use -derived differences in the distribution of P among fractions of different solubilities. However, interpretation of the results from extraction experiments requires better understanding of the biogeochemical function of the recovered P fraction in the P cycle in differently managed soils under dissimilar climatic conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis we present and evaluate two pattern matching based methods for answer extraction in textual question answering systems. A textual question answering system is a system that seeks answers to natural language questions from unstructured text. Textual question answering systems are an important research problem because as the amount of natural language text in digital format grows all the time, the need for novel methods for pinpointing important knowledge from the vast textual databases becomes more and more urgent. We concentrate on developing methods for the automatic creation of answer extraction patterns. A new type of extraction pattern is developed also. The pattern matching based approach chosen is interesting because of its language and application independence. The answer extraction methods are developed in the framework of our own question answering system. Publicly available datasets in English are used as training and evaluation data for the methods. The techniques developed are based on the well known methods of sequence alignment and hierarchical clustering. The similarity metric used is based on edit distance. The main conclusions of the research are that answer extraction patterns consisting of the most important words of the question and of the following information extracted from the answer context: plain words, part-of-speech tags, punctuation marks and capitalization patterns, can be used in the answer extraction module of a question answering system. This type of patterns and the two new methods for generating answer extraction patterns provide average results when compared to those produced by other systems using the same dataset. However, most answer extraction methods in the question answering systems tested with the same dataset are both hand crafted and based on a system-specific and fine-grained question classification. The the new methods developed in this thesis require no manual creation of answer extraction patterns. As a source of knowledge, they require a dataset of sample questions and answers, as well as a set of text documents that contain answers to most of the questions. The question classification used in the training data is a standard one and provided already in the publicly available data.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a measurement of the ratio of the tt̅ to Z/γ* production cross sections in √s=1.96  TeV pp̅ collisions using data corresponding to an integrated luminosity of up to 4.6  fb-1, collected by the CDF II detector. The tt̅ cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/γ*→ll cross section predicted by the standard model, the extracted tt̅ cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result σtt̅ =7.70±0.52  pb, for a top-quark mass of 172.5  GeV/c2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a measurement of the ratio of the tt̅ to Z/γ* production cross sections in √s=1.96  TeV pp̅ collisions using data corresponding to an integrated luminosity of up to 4.6  fb-1, collected by the CDF II detector. The tt̅ cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/γ*→ll cross section predicted by the standard model, the extracted tt̅ cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result σtt̅ =7.70±0.52  pb, for a top-quark mass of 172.5  GeV/c2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a measurement of the ratio of the top-antitop to Z/gamma* production cross sections in sqrt(s) = 1.96 TeV proton-antiproton collisions using data corresponding to an integrated luminosity of up to 4.6 fb-1, collected by the CDF II detector. The top-antitop cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/gamma*->ll cross section, the extracted top-antitop cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result sigma_(top-antitop) = 7.70 +/- 0.52 pb, for a top-quark mass of 172.5 GeV/c^2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of occupational chronic solvent encephalopathy (CSE) seems to decrease, but still every year reveals new cases. To prevent CSE and early retirement of solvent-exposed workers, actions should focus on early CSE detection and diagnosis. Identifying the work tasks and solvent exposure associated with high risk for CSE is crucial. Clinical and exposure data of all the 128 cases diagnosed with CSE as an occupational disease in Finland during 1995-2007 was collected from the patient records at the Finnish Institute of Occupational Health (FIOH) in Helsinki. The data on the number of exposed workers in Finland were gathered from the Finnish Job-exposure Matrix (FINJEM) and the number of employed from the national workforce survey. We analyzed the work tasks and solvent exposure of CSE patients and the findings in brain magnetic resonance imaging (MRI), quantitative electroencephalography (QEEG), and event-related potentials (ERP). The annual number of new cases diminished from 18 to 3, and the incidence of CSE decreased from 8.6 to 1.2 / million employed per year. The highest incidence of CSE was in workers with their main exposure to aromatic hydrocarbons; during 1995-2006 the incidence decreased from 1.2 to 0.3 / 1 000 exposed workers per year. The work tasks with the highest incidence of CSE were floor layers and lacquerers, wooden surface finishers, and industrial, metal, or car painters. Among 71 CSE patients, brain MRI revealed atrophy or white matter hyperintensities or both in 38% of the cases. Atrophy which was associated with duration of exposure was most frequently located in the cerebellum and in the frontal or parietal brain areas. QEEG in a group of 47 patients revealed increased power of the theta band in the frontal brain area. In a group of 86 patients, the P300 amplitude of auditory ERP was decreased, but at individual level, all the amplitude values were classified as normal. In 11 CSE patients and 13 age-matched controls, ERP elicited by a multimodal paradigm including an auditory, a visual detection, and a recognition memory task under single and dual-task conditions corroborated the decrease of auditory P300 amplitude in CSE patients in single-task condition. In dual-task conditions, the auditory P300 component was, more often in patients than in controls, unrecognizable. Due to the paucity and non-specificity of the findings, brain MRI serves mainly for differential diagnostics in CSE. QEEG and auditory P300 are insensitive at individual level and not useful in the clinical diagnostics of CSE. A multimodal ERP paradigm may, however, provide a more sensitive method to diagnose slight cognitive disturbances such as CSE.