6 resultados para radial breathing modes
em Helda - Digital Repository of University of Helsinki
Resumo:
Opioids are most commonly used for treatment of severe pain. However, the fear of respiratory depression has restricted the use of opioids. Depending on the monitoring system used, different modes of opioid respiratory effects have been noted in previous studies. All opioids also cause alterations in hemodynamics at least to some extent. The main goal of this series of investigations was to elucidate the native ventilatory and hemodynamic effects of different opioids. Studies I-IV each involved 8 healthy male volunteers. Study V involved 13 patients with lower or upper extremity traumas. The opioids studied were morphine, oxycodone, pethidine, fentanyl, alfentanil, tramadol and ketamine. The respiratory parameters used in this study were breathing pattern measured with respiratory inductive plethysmography, gas exchange measured with indirect calorimetry, blood gas analysis and pulse oximetry. Hemodynamics was measured with arterial blood pressure, heart rate and oxygen consumption. Plasma catecholamine and histamine concentrations were also determined. All opioids studied caused an alteration in respiratory function. Respiratory rate, alveolar ventilation and minute ventilation decreased, while tidal volume increased in most situations. Breathing pattern was also significantly affected after opioid administration. The respiratory depression caused by oxycodone was deeper than the one caused by same dose of morphine. An equianalgesic dose of tramadol caused markedly smaller respiratory depression compared to pethidine. The potency ratio for respiratory depression of fentanyl and alfentanil is similar to analgesic potency ratio studied elsewhere. Racemic ketamine attenuated the respiratory depression caused by fentanyl, if measured with minute ventilation. However, this effect was counteracted by increased oxygen consumption. Supplemental oxygen did not offer any benefits, nor did it cause any atelectasis when given to opioid treated trauma patients. Morphine caused a transient hemodynamic stimulation, which was accompanied by an increase in oxygen consumption. Oxycodone, alfentanil, fentanyl, tramadol and pethidine infusions had minimal effects on hemodynamics. Plasma catecholamine concentrations were increased after high dose opioid administration. Plasma histamine concentrations were not elevated after morphine nor oxycodone administration. Respiratory depression is a side effect noted with all opioids. The profile of this phenomenon is quite similar with different opioid-receptor agonists. The hemodynamic effects of opioids may vary depending on the opioid used, morphine causing a slight hemodynamic stimulation. However, all opioids studied could be considered hemodynamically stable.
Resumo:
The superconducting (or cryogenic) gravimeter (SG) is based on the levitation of a superconducting sphere in a stable magnetic field created by current in superconducting coils. Depending on frequency, it is capable of detecting gravity variations as small as 10-11ms-2. For a single event, the detection threshold is higher, conservatively about 10-9 ms-2. Due to its high sensitivity and low drift rate, the SG is eminently suitable for the study of geodynamical phenomena through their gravity signatures. I present investigations of Earth dynamics with the superconducting gravimeter GWR T020 at Metsähovi from 1994 to 2005. The history and key technical details of the installation are given. The data processing methods and the development of the local tidal model at Metsähovi are presented. The T020 is a part of the worldwide GGP (Global Geodynamics Project) network, which consist of 20 working station. The data of the T020 and of other participating SGs are available to the scientific community. The SG T020 have used as a long-period seismometer to study microseismicity and the Earth s free oscillation. The annual variation, spectral distribution, amplitude and the sources of microseism at Metsähovi were presented. Free oscillations excited by three large earthquakes were analyzed: the spectra, attenuation and rotational splitting of the modes. The lowest modes of all different oscillation types are studied, i.e. the radial mode 0S0, the "football mode" 0S2, and the toroidal mode 0T2. The very low level (0.01 nms-1) incessant excitation of the Earth s free oscillation was detected with the T020. The recovery of global and regional variations in gravity with the SG requires the modelling of local gravity effects. The most important of them is hydrology. The variation in the groundwater level at Metsähovi as measured in a borehole in the fractured bedrock correlates significantly (0.79) with gravity. The influence of local precipitation, soil moisture and snow cover are detectable in the gravity record. The gravity effect of the variation in atmospheric mass and that of the non-tidal loading by the Baltic Sea were investigated together, as sea level and air pressure are correlated. Using Green s functions it was calculated that a 1 metre uniform layer of water in the Baltic Sea increases the gravity at Metsähovi by 31 nms-2 and the vertical deformation is -11 mm. The regression coefficient for sea level is 27 nms-2m-1, which is 87% of the uniform model. These studies are associated with temporal height variations using the GPS data of Metsähovi permanent station. Results of long time series at Metsähovi demonstrated high quality of data and correctly carried out offsets and drift corrections. The superconducting gravimeter T020 has been proved to be an eminent and versatile tool in studies of the Earth dynamics.
Resumo:
The aim of this work was to examine how breathing, swallowing and voicing are affected in different laryngeal disorders. For this purpose, we examined four different patient groups: patients who had undergone total laryngectomy, anterior cervical decompression (ACD), or injection laryngoplasty with autologous fascia (ILAF), and patients with dyspnea during exercise. We studied the problems and benefits related to the automatic speech valve used for the rehabilitation of speech in laryngectomized patients. The device was given to 14 total laryngectomized patients who used the traditional valve especially well. The usefulness of voice and intelligibility of speech were assessed by speech pathologists. The results demonstrated better performance with the traditional valve in both dimensions. Most of the patients considered the automatic valve a helpful additional device but because of heavier breathing and the greater work needed for speech production, it was not suitable as a sole device in speech rehabilitation. Dysphonia and dysphagia are known complications of ACD. These symptoms are caused due to the stretching of tissue needed during the surgery, but the extent and the recovery from them was not well known before our study. We studied two patient groups, an early group with 50 patients who were examined immediately before and after the surgery and a late group with 64 patients who were examined 3 9 months postoperatively. Altogether, 60% reported dysphonia and 69% dysphagia immediately after the operation. Even though dysphagia and dysphonia often appeared after surgery, permanent problems seldom occurred. Six (12 %) cases of transient and two (3 %) permanent vocal cord paresis were detected. In our third study, the long-term results of ILAF in 43 patients with unilateral vocal cord paralysis were examined. The mean follow-up was 5.8 years (range 3 10). Perceptual evaluation demonstrated improved results for voice quality, and videostroboscopy revealed complete or partial glottal closure in 83% of the patients. Fascia showed to be a stable injection material with good vocal results. In our final study we developed a new diagnostic method for exertional laryngeal dyspnea by combining a cardiovascular exercise test with simultaneous fiberoptic observation of the larynx. With this method, it is possible to visualize paradoxal closure of the vocal cords during inspiration, which is a diagnostic criterion for vocal cord dysfunction (VCD). We examined 30 patients referred to our hospital because of suspicion of exercise-induced vocal cord dysfunction (EIVCD). Twenty seven out of thirty patients were able to perform the test. Dyspnea was induced in 15 patients, and of them five had EIVCD and four high suspicion of EIVCD. With our test it is possible to set an accurate diagnosis for exertional laryngeal dyspnea. Moreover, the often seen unnecessary use of asthma drugs among these patients can be avoided.