3 resultados para needs assessment
em Helda - Digital Repository of University of Helsinki
Resumo:
In the context of health care, information technology (IT) has an important role in the operational infrastructure, ranging from business management to patient care. An essential part of the system is medication management in inpatient and outpatient care. Community pharmacists strategy has been to extend practice responsibilities beyond dispensing towards patient care services. Few studies have evaluated the strategic development of IT systems to support this vision. The objectives of this study were to assess and compare independent Finnish community pharmacy owners and staff pharmacists priorities concerning the content and structure of the next generation of community pharmacy IT systems, to explore international experts visions and strategic views on IT development needs in relation to services provided in community pharmacies, to identify IT innovations facilitating patient care services and to evaluate their development and implementation processes, and to assess community pharmacists readiness to adopt innovations. This study applied both qualitative and quantitative methods. A qualitative personal interview of 14 experts in community pharmacy services and related IT from eight countries and a national survey of Finnish community pharmacy owners (mail survey, response rate 53%, n=308), and of a representative sample of staff pharmacists (online survey, response rate 22%, n=373) were conducted. Finnish independent community pharmacy owners gave priority to logistical functions but also to those related to medication information and patient care. The managers and staff pharmacists have different views of the importance of IT features, reflecting their different professional duties in the community pharmacy. This indicates the need for involving different occupation groups in planning the new IT systems for community pharmacies. A majority of the international experts shared the vision of community pharmacy adopting a patient care orientation; supported by IT-based documentation, new technological solutions, access to information, and shared patient data. Community pharmacy IT innovations were rare, which is paradoxical because owners and staff pharmacists perception of their innovativeness was seen as being high. Community pharmacy IT systems development processes usually had not undergone systematic needs assessment research beforehand or evaluation after the implementation and were most often coordinated by national governments without subsequent commercialization. Specifically, community pharmacy IT developments lack research, organization, leadership and user involvement in the process. Those responsible for IT development in the community pharmacy sector should create long-term IT development strategies that are in line with community pharmacy service development strategies. This could provide systematic guidance for future projects to ensure that potential innovations are based on a sufficient understanding of pharmacy practice problems that they are intended to solve, and to encourage strong leadership in research, development of innovations so that community pharmacists potential innovativeness is used, and that professional needs and strategic priorities will be considered even if the development process is led by those outside the profession.
Resumo:
In recent years, concern has arisen over the effects of increasing carbon dioxide (CO2) in the earth's atmosphere due to the burning of fossil fuels. One way to mitigate increase in atmospheric CO2 concentration and climate change is carbon sequestration to forest vegeta-tion through photosynthesis. Comparable regional scale estimates for the carbon balance of forests are therefore needed for scientific and political purposes. The aim of the present dissertation was to improve methods for quantifying and verifying inventory-based carbon pool estimates of the boreal forests in the mineral soils. Ongoing forest inventories provide a data based on statistically sounded sampling for estimating the level of carbon stocks and stock changes, but improved modelling tools and comparison of methods are still needed. In this dissertation, the entire inventory-based large-scale forest carbon stock assessment method was presented together with some separate methods for enhancing and comparing it. The enhancement methods presented here include ways to quantify the biomass of understorey vegetation as well as to estimate the litter production of needles and branches. In addition, the optical remote sensing method illustrated in this dis-sertation can be used to compare with independent data. The forest inventory-based large-scale carbon stock assessment method demonstrated here provided reliable carbon estimates when compared with independent data. Future ac-tivity to improve the accuracy of this method could consist of reducing the uncertainties regarding belowground biomass and litter production as well as the soil compartment. The methods developed will serve the needs for UNFCCC reporting and the reporting under the Kyoto Protocol. This method is principally intended for analysts or planners interested in quantifying carbon over extensive forest areas.
Resumo:
Several hypnosis monitoring systems based on the processed electroencephalogram (EEG) have been developed for use during general anesthesia. The assessment of the analgesic component (antinociception) of general anesthesia is an emerging field of research. This study investigated the interaction of hypnosis and antinociception, the association of several physiological variables with the degree of intraoperative nociception, and aspects of EEG Bispectral Index Scale (BIS) monitoring during general anesthesia. In addition, EEG features and heart rate (HR) responses during desflurane and sevoflurane anesthesia were compared. A propofol bolus of 0.7 mg/kg was more effective than an alfentanil bolus of 0.5 mg in preventing the recurrence of movement responses during uterine dilatation and curettage (D C) after a propofol-alfentanil induction, combined with nitrous oxide (N2O). HR and several HR variability-, frontal electromyography (fEMG)-, pulse plethysmography (PPG)-, and EEG-derived variables were associated with surgery-induced movement responses. Movers were discriminated from non-movers mostly by the post-stimulus values per se or normalized with respect to the pre-stimulus values. In logistic regression analysis, the best classification performance was achieved with the combination of normalized fEMG power and HR during D C (overall accuracy 81%, sensitivity 53%, specificity 95%), and with the combination of normalized fEMG-related response entropy, electrocardiography (ECG) R-to-R interval (RRI), and PPG dicrotic notch amplitude during sevoflurane anesthesia (overall accuracy 96%, sensitivity 90%, specificity 100%). ECG electrode impedances after alcohol swab skin pretreatment alone were higher than impedances of designated EEG electrodes. The BIS values registered with ECG electrodes were higher than those registered simultaneously with EEG electrodes. No significant difference in the time to home-readiness after isoflurane-N2O or sevoflurane-N2O anesthesia was found, when the administration of the volatile agent was guided by BIS monitoring. All other early and intermediate recovery parameters were also similar. Transient epileptiform EEG activity was detected in eight of 15 sevoflurane patients during a rapid increase in the inspired volatile concentration, and in none of the 16 desflurane patients. The observed transient EEG changes did not adversely affect the recovery of the patients. Following the rapid increase in the inhaled desflurane concentration, HR increased transiently, reaching its maximum in two minutes. In the sevoflurane group, the increase was slower and more subtle. In conclusion, desflurane may be a safer volatile agent than sevoflurane in patients with a lowered seizure threshold. The tachycardia induced by a rapid increase in the inspired desflurane concentration may present a risk for patients with heart disease. Designated EEG electrodes may be superior to ECG electrodes in EEG BIS monitoring. When the administration of isoflurane or sevoflurane is adjusted to maintain BIS values at 50-60 in healthy ambulatory surgery patients, the speed and quality of recovery are similar after both isoflurane-N2O and sevoflurane-N2O anesthesia. When anesthesia is maintained by the inhalation of N2O and bolus doses of propofol and alfentanil in healthy unparalyzed patients, movement responses may be best avoided by ensuring a relatively deep hypnotic level with propofol. HR/RRI, fEMG, and PPG dicrotic notch amplitude are potential indicators of nociception during anesthesia, but their performance needs to be validated in future studies. Combining information from different sources may improve the discrimination of the level of nociception.