6 resultados para metabolismo cellulare, modellistica, approccio su più livelli, fosforilazione ossidativa, sistema biologico
em Helda - Digital Repository of University of Helsinki
Resumo:
Miniaturization of analytical instrumentation is attracting growing interest in response to the explosive demand for rapid, yet sensitive analytical methods and low-cost, highly automated instruments for pharmaceutical and bioanalyses and environmental monitoring. Microfabrication technology in particular, has enabled fabrication of low-cost microdevices with a high degree of integrated functions, such as sample preparation, chemical reaction, separation, and detection, on a single microchip. These miniaturized total chemical analysis systems (microTAS or lab-on-a-chip) can also be arrayed for parallel analyses in order to accelerate the sample throughput. Other motivations include reduced sample consumption and waste production as well as increased speed of analysis. One of the most promising hyphenated techniques in analytical chemistry is the combination of a microfluidic separation chip and mass spectrometer (MS). In this work, the emerging polymer microfabrication techniques, ultraviolet lithography in particular, were exploited to develop a capillary electrophoresis (CE) separation chip which incorporates a monolithically integrated electrospray ionization (ESI) emitter for efficient coupling with MS. An epoxy photoresist SU-8 was adopted as structural material and characterized with respect to its physicochemical properties relevant to chip-based CE and ESI/MS, namely surface charge, surface interactions, heat transfer, and solvent compatibility. As a result, SU-8 was found to be a favorable material to substitute for the more commonly used glass and silicon in microfluidic applications. In addition, an infrared (IR) thermography was introduced as direct, non-intrusive method to examine the heat transfer and thermal gradients during microchip-CE. The IR data was validated through numerical modeling. The analytical performance of SU-8-based microchips was established for qualitative and quantitative CE-ESI/MS analysis of small drug compounds, peptides, and proteins. The CE separation efficiency was found to be similar to that of commercial glass microchips and conventional CE systems. Typical analysis times were only 30-90 s per sample indicating feasibility for high-throughput analysis. Moreover, a mass detection limit at the low-attomole level, as low as 10E+5 molecules, was achieved utilizing MS detection. The SU-8 microchips developed in this work could also be mass produced at low cost and with nearly identical performance from chip to chip. Until this work, the attempts to combine CE separation with ESI in a chip-based system, amenable to batch fabrication and capable of high, reproducible analytical performance, have not been successful. Thus, the CE-ESI chip developed in this work is a substantial step toward lab-on-a-chip technology.
Resumo:
The analysis uses data from an integrated luminosity of approximately 172 pb-1 of ppbar collisions at sqrt(s)=1.96 TeV, collected with the CDF II detector at the Fermilab Tevatron. The Lambda_b and B0 relative branching fractions are measured to be: B(Lambda_b to Lambda_c+ mu nu)/B(Lambda_b to Lambda_c+ pi) = 16.6 +- 3.0 (stat) +- 1.0 (syst) +2.6 -3.4 (PDG) +- 0.3 (EBR), B(B0 to D+ mu nu)/B(B0 to D+ pi) = 9.9 +- 1.0 (stat) +- 0.6 (syst) +- 0.4 (PDG) +- 0.5 (EBR), B(B0 to D*+ mu nu)/B(B0 to D*+ pi) = 16.5 +- 2.3 (stat) +- 0.6 (syst) +- 0.5 (PDG) +- 0.8 (EBR) This article also presents measurements of the branching fractions of four new Lambda_b semileptonic decays: Lambda_b to Lambda_c(2595)+ mu nu, Lambda_b to Lambda_c(2625)+ mu nu, Lambda_b to Sigma_c(2455)0 pi mu nu, Lambda_b to Sigma_c(2455)++ pi mu nu, relative to the branching fraction of the Lambda_b to Lambda_c mu nu decay. Finally, the transverse-momentum distribution of Lambda_b baryons produced in p-pbar collisions is measured and found to be significantly different from that of B0 mesons.
Resumo:
A combined mass and particle identification fit is used to make the first observation of the decay Bs --> Ds K and measure the branching fraction of Bs --> Ds K relative to Bs --> Ds pi. This analysis uses 1.2 fb^-1 integrated luminosity of pbar-p collisions at sqrt(s) = 1.96 TeV collected with the CDF II detector at the Fermilab Tevatron collider. We observe a Bs --> Ds K signal with a statistical significance of 8.1 sigma and measure Br(Bs --> Ds K)/Br(Bs --> Ds pi) = 0.097 +- 0.018(stat) +- 0.009(sys).