5 resultados para anestesiologia

em Helda - Digital Repository of University of Helsinki


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Breast reconstruction is performed for 10-15 % of women operated on for breast cancer. A popular method is the TRAM (transverse rectus abdominis musculocutaneous) flap formed of the patient’s own abdominal tissue, a part of one of the rectus abdominis muscles and a transverse skin-subcutis area over it. The flap can be raised as a pedicled or a free flap. The pedicled TRAM flap, based on its nondominant pedicle superior epigastric artery (SEA), is rotated to the chest so that blood flow through SEA continues. The free TRAM flap, based on its dominant pedicle deep inferior epigastric artery (DIEA), is detached from the abdomen, transferred to the chest, and DIEA and vein are anastomosed to vessels on the chest. Cutaneous necrosis is seen in 5–60 % of pedicled TRAM flaps and in 0–15 % of free TRAM flaps. This study was the first one to show with blood flow measurements that the cutaneous blood flow is more generous in free than in pedicled TRAM flaps. After this study the free TRAM flap has exceeded the pedicled flap in popularity as a breast reconstruction method, although the free flap it is technically a more demanding procedure than the pedicled TRAM flap. In pedicled flaps, a decrease in cutaneous blood flow was observed when DIEA was ligated. It seems that SEA cannot provide sufficient blood flow on the first postoperative days. The postoperative cutaneous blood flow in free TRAM flaps was more stable than in pedicled flaps. Development of cutaneous necrosis of pedicled TRAM flaps could be predicted based on intraoperative laser Doppler flowmetry (LDF) measurements. The LDF value on the contralateral skin of the flap decreased to 43 ± 7 % of the initial value after ligation of the DIEA in flaps developing cutaneous necrosis during the next week. Endothelin-1 (ET-1) is a powerful vasoconstrictory peptide secreted by vascular endothelial cells. A correlation was found between plasma ET-1 concentrations and peripheral vasoconstriction developing during and after breast reconstructions with a pedicled TRAM flap. ET-1 was not associated with the development of cutaneous necrosis. Felodipine, a vasodilating calcium channel antagonist, had no effect on plasma ET-1 concentrations, peripheral vasoconstriction or development of cutaneous necrosis in free TRAM flaps. Body mass index and thickness of abdominal were not associated with cutaneous necrosis in pedicled TRAM flaps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aging population is placing increasing demands on surgical services, simultaneously with a decreasing supply of professional labor and a worsening economic situation. Under growing financial constraints, successful operating room management will be one of the key issues in the struggle for technical efficiency. This study focused on several issues affecting operating room efficiency. Materials and methods: The current formal operating room management in Finland and the use of performance metrics and information systems used to support this management were explored using a postal survey. We also studied the feasibility of a wireless patient tracking system as a tool for managing the process. The reliability of the system as well as the accuracy and precision of its automatically recorded time stamps were analyzed. The benefits of a separate anesthesia induction room in a prospective setting were compared with the traditional way of working, where anesthesia is induced in the operating room. Using computer simulation, several models of parallel processing for the operating room were compared with the traditional model with respect to cost-efficiency. Moreover, international differences in operating room times for two common procedures, laparoscopic cholecystectomy and open lung lobectomy, were investigated. Results: The managerial structure of Finnish operating units was not clearly defined. Operating room management information systems were found to be out-of-date, offering little support to online evaluation of the care process. Only about half of the information systems provided information in real time. Operating room performance was most often measured by the number of procedures in a time unit, operating room utilization, and turnover time. The wireless patient tracking system was found to be feasible for hospital use. Automatic documentation of the system facilitated patient flow management by increasing process transparency via more available and accurate data, while lessening work for staff. Any parallel work flow model was more cost-efficient than the traditional way of performing anesthesia induction in the operating room. Mean operating times for two common procedures differed by 50% among eight hospitals in different countries. Conclusions: The structure of daily operative management of an operating room warrants redefinition. Performance measures as well as information systems require updating. Parallel work flows are more cost-efficient than the traditional induction-in-room model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Continuous epidural analgesia (CEA) and continuous spinal postoperative analgesia (CSPA) provided by a mixture of local anaesthetic and opioid are widely used for postoperative pain relief. E.g., with the introduction of so-called microcatheters, CSPA found its way particularly in orthopaedic surgery. These techniques, however, may be associated with dose-dependent side-effects as hypotension, weakness in the legs, and nausea and vomiting. At times, they may fail to offer sufficient analgesia, e.g., because of a misplaced catheter. The correct position of an epidural catheter might be confirmed by the supposedly easy and reliable epidural stimulation test (EST). The aims of this thesis were to determine a) whether the efficacy, tolerability, and reliability of CEA might be improved by adding the α2-adrenergic agonists adrenaline and clonidine to CEA, and by the repeated use of EST during CEA; and, b) the feasibility of CSPA given through a microcatheter after vascular surgery. Studies I IV were double-blinded, randomized, and controlled trials; Study V was of a diagnostic, prospective nature. Patients underwent arterial bypass surgery of the legs (I, n=50; IV, n=46), total knee arthroplasty (II, n=70; III, n=72), and abdominal surgery or thoracotomy (V, n=30). Postoperative lumbar CEA consisted of regular mixtures of ropivacaine and fentanyl either without or with adrenaline (2 µg/ml (I) and 4 µg/ml (II)) and clonidine (2 µg/ml (III)). CSPA (IV) was given through a microcatheter (28G) and contained either ropivacaine (max. 2 mg/h) or a mixture of ropivacaine (max. 1 mg/h) and morphine (max. 8 µg/h). Epidural catheter tip position (V) was evaluated both by EST at the moment of catheter placement and several times during CEA, and by epidurography as reference diagnostic test. CEA and CSPA were administered for 24 or 48 h. Study parameters included pain scores assessed with a visual analogue scale, requirements of rescue pain medication, vital signs, and side-effects. Adrenaline (I and II) had no beneficial influence as regards the efficacy or tolerability of CEA. The total amounts of epidurally-infused drugs were even increased in the adrenaline group in Study II (p=0.02, RM ANOVA). Clonidine (III) augmented pain relief with lowered amounts of epidurally infused drugs (p=0.01, RM ANOVA) and reduced need for rescue oxycodone given i.m. (p=0.027, MW-U; median difference 3 mg (95% CI 0 7 mg)). Clonidine did not contribute to sedation and its influence on haemodynamics was minimal. CSPA (IV) provided satisfactory pain relief with only limited blockade of the legs (no inter-group differences). EST (V) was often related to technical problems and difficulties of interpretation, e.g., it failed to identify the four patients whose catheters were outside the spinal canal already at the time of catheter placement. As adjuvants to lumbar CEA, clonidine only slightly improved pain relief, while adrenaline did not provide any benefit. The role of EST applied at the time of epidural catheter placement or repeatedly during CEA remains open. The microcatheter CSPA technique appeared effective and reliable, but needs to be compared to routine CEA after peripheral arterial bypass surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sudden cardiac arrest (CA) is one of the leading causes of death in Europe. It has been estimated that about 40 % of CA victims have ventricular fibrillation (VF) at the time of the first heart rhythm analysis. The treatment for VF is immediate cardiopulmonary resuscitation (CPR) and rapid defibrillation. The automated external defibrillator (AED) and the concept of public access defibrillation (PAD) may be a key to shortening defibrillation delays. Recent studies have shown that PAD programs are associated with high survival rates from VF when devices have been placed in certain risk sites and used by trained laypersons. Today many public places are equipped with AEDs. The purpose of this study was to find new ways of utilizing layperson defibrillation and promote the concept of public access defibrillation (PAD). The study explored the use of AEDs by non-medical first responders in Finland and cabin crew on board a commercial aircraft. A simulated study was performed to explore the role of dispatcher assistance in layperson CPR and defibrillation. A 15-year follow-up study of 59 one-year survivors after successful out-of-hospital resuscitation was performed to evaluate the long-term quality of life of the CA patients. Although there are many AEDs in use by non-medical first responders in Finland, the results of the study showed that there are large variations between individual first response units. This is considered to be caused by the lack of national standards and regulations that would define a full integration of first-responder programmes into the Emergency Medical Services system. The goal of rapid defibrillation in five minutes after the onset of CA is difficult to achieve in Finland due to sparse population and long distances. Local PAD programs may shorten the defibrillation delays. Dispatcher assistance in defibrillation by a layperson not trained to use an AED seems feasible and does not compromise the performance of CPR. In a simulated study, the quality of mouth-to-mouth ventilation performed by laypersons was found to be better after CPR training compared with performance with dispatcher assistance before training. Training was not found to have an influence on the quality of compressions or defibrillation compared with dispatcher assistance of untrained laypersons. The target groups for CPR and defibrillation training need further evaluation. The placements of the AEDs in public areas should be known by the emergency response center and the location should be marked with an international sign. The finding that once a good neurological outcome after CA is achieved, it can be maintained for more than 10 years, encourages further efforts to improve the survival of CA patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The national resuscitation guidelines were published in Finland in 2002 and are based on international guidelines published in 2000. The main goal of the national guidelines, available on the Internet free of charge, is early defibrillation by nurses in an institutional setting. Aim: To study possible changes in cardiopulmonary resuscitation (CPR) practices, especially concerning early defibrillation, nurses and students attitudes of guideline implementation and nurses and students ability to implement the guideline recommendations in clinical practices after publication of the Current Care (CC) guidelines for CPR 2002. Material and methods: CPR practices in Finnish health centres; especially concerning rapid defibrillation programmes, as well as the implementation of CC guidelines for CPR was studied in a mail survey to chief physicians of every health centre in Finland (Study I). The CPR skills using an automated external defibrillator (AED) were compared in a study including Objective stuctured clinical examination (OSCE) of resuscitation skills of nurses and nursing students in Finnish and Swedish hospital and institution (Studies II, III). Attitudes towards CPR-D and CPR guidelines among medical and nursing students and secondary hospital nurses were studied in surveys (Studies IV, V). The nurses receiving different CPR training were compared in a randomized trial including OSCE of CPR skills of nurses in Finnish Hospital (Study VI). Results: Two years after the publication, 40.7% of Finnish health centres used national resuscitation guidelines. The proportion of health centres having at least one AED (66%) and principle of nurse-performed defibrillation without the presence of a physician (42%) had increased. The CPR-D training was estimated to be insufficient regarding basic life support and advanced life support in the majority of health centres (Study I). CPR-D skills of nurses and nursing students in two specific Swedish and Finnish hospitals and institutions (Study II and III) were generally inadequate. The nurses performed better than the students and the Swedish nurses surpassed the Finnish ones. Geriatric nurses receiving traditional CPR-D training performed better than those receiving an Internet-based course but both groups failed to defibrillate within 60 s. Thus, the performance was not satisfactory even two weeks after traditional training (Study VI). Unlike the medical students, the nursing students did not feel competent to perform procedures recommended in the cardiopulmonary resuscitation guidelines including the defibrillation. However, the majority of nursing students felt confident about their ability to perform basic life support. The perceived ability to defibrillate correlated significantly with a positive attitude towards nurse-performed defibrillation and negatively with fear of damaging the patient s heart by defibrillation (Study IV). After the educational intervention, the nurses found their level of CPR-D capability more sufficient than before and felt more confident about their ability to perform defibrillation themselves. A negative attitude toward defibrillation correlated with perceived negative organisational attitudes toward cardiopulmonary resuscitation guidelines. After CPR-D education in the hospital, the majority (64%) of nurses hesitated to perform defibrillation because of anxiety and 27 % hesitated because of fear of injuring the patient. Also a negative personal attitude towards guidelines increased markedly after education (Study V). Conclusions: Although a significant change had occurred in resuscitation practices in primary health care after publication of national cardiopulmonary resuscitation guidelines the participants CPR-D skills were not adequate according to the CPR guidelines. The current way of teaching is unlikely to result in participants being able to perform adequate and rapid CPR-D. More information and more frequent training are needed to diminish anxiety concerning defibrillation. Negative beliefs and attitudes toward defibrillation affect the nursing students and nurses attitudes toward cardiopulmonary resuscitation guidelines. CPR-D education increased the participants self-confidence concerning CPR-D skills but it did not reduce their anxiety. AEDs have replaced the manual defibrillators in most institutions, but in spite of the modern devices the anxiety still exists. Basic education does not provide nursing students with adequate CPR-D skills. Thus, frequent training in the workplace has vital importance. This multi-professional program supported by the administration might provide better CPR-D skills. Distance learning alone cannot substitute for traditional small-group learning, tutored hands-on training is needed to learn practical CPR-D skills. Standardized testing would probably help controlling the quality of learning. Training of group-working skills might improve CPR performance.