3 resultados para Variable pressure scanning electron microscope

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The research reported in this thesis dealt with single crystals of thallium bromide grown for gamma-ray detector applications. The crystals were used to fabricate room temperature gamma-ray detectors. Routinely produced TlBr detectors often are poor quality. Therefore, this study concentrated on developing the manufacturing processes for TlBr detectors and methods of characterisation that can be used for optimisation of TlBr purity and crystal quality. The processes under concern were TlBr raw material purification, crystal growth, annealing and detector fabrication. The study focused on single crystals of TlBr grown from material purified by a hydrothermal recrystallisation method. In addition, hydrothermal conditions for synthesis, recrystallisation, crystal growth and annealing of TlBr crystals were examined. The final manufacturing process presented in this thesis deals with TlBr material purified by the Bridgman method. Then, material is hydrothermally recrystallised in pure water. A travelling molten zone (TMZ) method is used for additional purification of the recrystallised product and then for the final crystal growth. Subsequent processing is similar to that described in the literature. In this thesis, literature on improving quality of TlBr material/crystal and detector performance is reviewed. Aging aspects as well as the influence of different factors (temperature, time, electrode material and so on) on detector stability are considered and examined. The results of the process development are summarised and discussed. This thesis shows the considerable improvement in the charge carrier properties of a detector due to additional purification by hydrothermal recrystallisation. As an example, a thick (4 mm) TlBr detector produced by the process was fabricated and found to operate successfully in gamma-ray detection, confirming the validity of the proposed purification and technological steps. However, for the complete improvement of detector performance, further developments in crystal growth are required. The detector manufacturing process was optimized by characterisation of material and crystals using methods such as X-ray diffraction (XRD), polarisation microscopy, high-resolution inductively coupled plasma mass (HR-ICPM), Fourier transform infrared (FTIR), ultraviolet and visual (UV-Vis) spectroscopy, field emission scanning electron microscope (FESEM) and energy-dispersive X-ray spectroscopy (EDS), current-voltage (I-V) and capacity voltage (CV) characterisation, and photoconductivity, as well direct detector examination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Generation of raw materials for dry powder inhalers by different size reduction methods can be expected to influence physical and chemical properties of the powders. This can cause differences in particle size, size distribution, shape, crystalline properties, surface texture and energy. These physical properties of powders influence the behaviour of particles before and after inhalation. Materials with an amorphous surface have different surface energy compared to materials with crystalline surface. This can affect the adhesion and cohesion of particles. Changes in the surface nature of the drug particles results in a change in product performance. By stabilization of the raw materials the amorphous surfaces are converted into crystalline surfaces. The primary aim of the study was to investigate the influence of the surface properties of the inhalation particles on the quality of the product. The quality of the inhalation product is evaluated by measuring the fine particle dose (FPD). FDP is the total dose of particles with aerodynamic diameters smaller than 5,0 μm. The secondary aim of this study was to achieve the target level of the FPD and the stability of the FPD. This study was also used to evaluate the importance of the stabilization of the inhalation powders. The study included manufacturing and analysing drug substance 200 μg/dose inhalation powder batches using non-stabilized or stabilized raw materials. The inhaler formulation consisted of micronized drug substance, lactose <100μm and micronized lactose <10μm. The inhaler device was Easyhaler®. Stabilization of the raw materials was done in different relative humidity, temperature and time. Surface properties of the raw materials were studied by dynamic vapour sorption, scanning electron microscopy and three-point nitrogen adsorption technique. Particle size was studied by laser diffraction particle size analyzer. Aerodynamic particle size distribution from inhalers was measured by new generation impactor. Stabilization of all three raw materials was successful. A clear difference between nonstabilized and stabilized raw materials was achieved for drug substance and lactose <10μm. However for lactose <100μm the difference wasn’t as clear as wanted. The surface of the non-stabilized drug substance was more irregular and the particles had more roughness on the surface compared to the stabilized drug substances particles surface. The surface of the stabilized drug particles was more regular and smoother than non-stabilized. Even though a good difference between stabilized and non-stabilized raw materials was achieved, a clear evidence of the effect of the surface properties of the inhalation particles on the quality of the product was not observed. Stabilization of the raw materials didn’t lead to a higher FPD. Possible explanations for the unexpected result might be too rough conditions in the stabilization of the drug substance or smaller than wanted difference in the degree of stabilization of the main component of the product <100μm. Despite positive effects on the quality of the product were not seen there appears to be some evidence that stabilized drug substance results in smaller particle size of dry powder inhalers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Emulsiokalvolla tarkoitetaan kalvoa, joka on valmistettu haihduttamalla ylimääräinen vesi pois emulsiosta. Polysakkaridipohjainen emulsiokalvo koostuu kalvonmuodostuspolysakkaridista, rasvasta, emulgointiaineesta ja pehmittimestä. Kirjallisuusosassa selvitettiin, mitä raaka-aineita polysakkaridipohjaisissa emulsiokalvoissa käytetään ja mitkä tekijät vaikuttavat emulsiokalvojen vesihöyrynläpäisevyyteen ja mekaanisiin ominaisuuksiin. Tutkimuksen kokeellisen osan tavoitteena oli selvittää, miten konjac-glukomannaani (KGM) ja kuusen galaktoglukomannaani (GGM) soveltuvat emulsiokalvon raaka-aineiksi. Lisäksi selvitettiin, miten rasvan tyyppi ja rasvapitoisuus vaikuttavat GGM-KGM-pohjaisten emulsiokalvojen mekaanisiin ominaisuuksiin ja vesihöyrynläpäisevyyteen. Mehiläisvahasta, mäntyöljystä ja rypsiöljystä valmistettiin emulsiokalvot, joissa oli 30 %:n (paino-% GGM:sta) rasvapitoisuudet. Lisäksi mehiläisvahasta valmistettiin emulsiokalvot, joissa oli 10 ja 50 % mehiläisvahaa. Emulsiokalvoja verrattiin vertailukalvoon, jossa ei ollut rasvaa. Kalvoissa käytetty KGM:n ja GGM:n suhde oli 1:1. Kalvoista mitattiin vesihöyrynläpäisevyys ja -läpäisynopeus, vetolujuus, Youngin moduuli ja murtovenymä. Näiden lisäksi kalvojen poikkileikkaus kuvattiin pyyhkäisyelektronimikroskoopilla. GGM ja KGM soveltuvat emulsiokalvon raaka-aineiksi. Huoneenlämpötilassa kuivatuista kalvoista saatiin tasaisemman näköisiä kuin lämpökaapissa kuivatuista. Pyyhkäisyelektronimikroskooppikuvissa vahapisarat olivat öljypisaroita pienempiä, mikä mahdollisesti vaikutti siihen, että vahapisarat pysyivät paremmin kiinnittyneenä kalvomatriisissa. Öljypisaroiden koko oli kalvoissa noin 10 ?m ja vahapisaroiden 2–6 ?m. Vesihöyrynläpäisynopeus oli pienin 50 %:n mehiläisvahakalvolla (p < 0,05). Vesihöyrynläpäisevyys laski lineaarisesti mehiläisvahapitoisuuden suurentuessa. Öljykalvot ja 10 %:n mehiläisvahakalvo eivät eronneet tilastollisesti merkitsevästi vesihöyrynläpäisevyyden suhteen vertailukalvosta. Pienin vetolujuus ja Youngin moduuli oli 50 %:n mehiläisvahakalvolla. Vertailukalvo oli kestävin ja jäykin. Murtovenymän suhteen kalvot eivät eronneet toisistaan tilastollisesti merkitsevästi. Tutkimuksessa onnistuttiin valmistamaan GGM-KGM-pohjaisia emulsiokalvoja, jotka pidättivät vesihöyryä vertailukalvoa paremmin ja silti säilyttivät mekaaniset ominaisuutensa kohtuullisen hyvin.