13 resultados para Tidal Volume

em Helda - Digital Repository of University of Helsinki


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Opioids are most commonly used for treatment of severe pain. However, the fear of respiratory depression has restricted the use of opioids. Depending on the monitoring system used, different modes of opioid respiratory effects have been noted in previous studies. All opioids also cause alterations in hemodynamics at least to some extent. The main goal of this series of investigations was to elucidate the native ventilatory and hemodynamic effects of different opioids. Studies I-IV each involved 8 healthy male volunteers. Study V involved 13 patients with lower or upper extremity traumas. The opioids studied were morphine, oxycodone, pethidine, fentanyl, alfentanil, tramadol and ketamine. The respiratory parameters used in this study were breathing pattern measured with respiratory inductive plethysmography, gas exchange measured with indirect calorimetry, blood gas analysis and pulse oximetry. Hemodynamics was measured with arterial blood pressure, heart rate and oxygen consumption. Plasma catecholamine and histamine concentrations were also determined. All opioids studied caused an alteration in respiratory function. Respiratory rate, alveolar ventilation and minute ventilation decreased, while tidal volume increased in most situations. Breathing pattern was also significantly affected after opioid administration. The respiratory depression caused by oxycodone was deeper than the one caused by same dose of morphine. An equianalgesic dose of tramadol caused markedly smaller respiratory depression compared to pethidine. The potency ratio for respiratory depression of fentanyl and alfentanil is similar to analgesic potency ratio studied elsewhere. Racemic ketamine attenuated the respiratory depression caused by fentanyl, if measured with minute ventilation. However, this effect was counteracted by increased oxygen consumption. Supplemental oxygen did not offer any benefits, nor did it cause any atelectasis when given to opioid treated trauma patients. Morphine caused a transient hemodynamic stimulation, which was accompanied by an increase in oxygen consumption. Oxycodone, alfentanil, fentanyl, tramadol and pethidine infusions had minimal effects on hemodynamics. Plasma catecholamine concentrations were increased after high dose opioid administration. Plasma histamine concentrations were not elevated after morphine nor oxycodone administration. Respiratory depression is a side effect noted with all opioids. The profile of this phenomenon is quite similar with different opioid-receptor agonists. The hemodynamic effects of opioids may vary depending on the opioid used, morphine causing a slight hemodynamic stimulation. However, all opioids studied could be considered hemodynamically stable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel method for functional lung imaging was introduced by adapting the K-edge subtraction method (KES) to in vivo studies of small animals. In this method two synchrotron radiation energies, which bracket the K-edge of the contrast agent, are used for simultaneous recording of absorption-contrast images. Stable xenon gas is used as the contrast agent, and imaging is performed in projection or computed tomography (CT) mode. Subtraction of the two images yields the distribution of xenon, while removing practically all features due to other structures, and the xenon density can be calculated quantitatively. Because the images are recorded simultaneously, there are no movement artifacts in the subtraction image. Time resolution for a series of CT images is one image/s, which allows functional studies. Voxel size is 0.1mm3, which is an order better than in traditional lung imaging methods. KES imaging technique was used in studies of ventilation distribution and the effects of histamine-induced airway narrowing in healthy, mechanically ventilated, and anaesthetized rabbits. First, the effect of tidal volume on ventilation was studied, and the results show that an increase in tidal volume without an increase in minute ventilation results a proportional increase in regional ventilation. Second, spiral CT was used to quantify the airspace volumes in lungs in normal conditions and after histamine aerosol inhalation, and the results showed large patchy filling defects in peripheral lungs following histamine provocation. Third, the kinetics of proximal and distal airway response to histamine aerosol were examined, and the findings show that the distal airways react immediately to histamine and start to recover, while the reaction and the recovery in proximal airways is slower. Fourth, the fractal dimensions of lungs was studied, and it was found that the fractal dimension is higher at the apical part of the lungs compared to the basal part, indicating structural differences between apical and basal lung level. These results provide new insights to lung function and the effects of drug challenge studies. Nowadays the technique is available at synchrotron radiation facilities, but the compact synchrotron radiation sources are being developed, and in relatively near future the method may be used at hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluates how the advection of precipitation, or wind drift, between the radar volume and ground affects radar measurements of precipitation. Normally precipitation is assumed to fall vertically to the ground from the contributing volume, and thus the radar measurement represents the geographical location immediately below. In this study radar measurements are corrected using hydrometeor trajectories calculated from measured and forecasted winds, and the effect of trajectory-correction on the radar measurements is evaluated. Wind drift statistics for Finland are compiled using sounding data from two weather stations spanning two years. For each sounding, the hydrometeor phase at ground level is estimated and drift distance calculated using different originating level heights. This way the drift statistics are constructed as a function of range from radar and elevation angle. On average, wind drift of 1 km was exceeded at approximately 60 km distance, while drift of 10 km was exceeded at 100 km distance. Trajectories were calculated using model winds in order to produce a trajectory-corrected ground field from radar PPI images. It was found that at the upwind side from the radar the effective measuring area was reduced as some trajectories exited the radar volume scan. In the downwind side areas near the edge of the radar measuring area experience improved precipitation detection. The effect of trajectory-correction is most prominent in instant measurements and diminishes when accumulating over longer time periods. Furthermore, measurements of intensive and small scale precipitation patterns benefit most from wind drift correction. The contribution of wind drift on the uncertainty of estimated Ze (S) - relationship was studied by simulating the effect of different error sources to the uncertainty in the relationship coefficients a and b. The overall uncertainty was assumed to consist of systematic errors of both the radar and the gauge, as well as errors by turbulence at the gauge orifice and by wind drift of precipitation. The focus of the analysis is error associated with wind drift, which was determined by describing the spatial structure of the reflectivity field using spatial autocovariance (or variogram). This spatial structure was then used with calculated drift distances to estimate the variance in radar measurement produced by precipitation drift, relative to the other error sources. It was found that error by wind drift was of similar magnitude with error by turbulence at gauge orifice at all ranges from radar, with systematic errors of the instruments being a minor issue. The correction method presented in the study could be used in radar nowcasting products to improve the estimation of visibility and local precipitation intensities. The method however only considers pure snow, and for operational purposes some improvements are desirable, such as melting layer detection, VPR correction and taking solid state hydrometeor type into account, which would improve the estimation of vertical velocities of the hydrometeors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients may need massive volume-replacement therapy after cardiac surgery because of large fluid transfer perioperatively, and the use of cardiopulmonary bypass. Hemodynamic stability is better maintained with colloids than crystalloids but colloids have more adverse effects such as coagulation disturbances and impairment of renal function than do crystalloids. The present study examined the effects of modern hydroxyethyl starch (HES) and gelatin solutions on blood coagulation and hemodynamics. The mechanism by which colloids disturb blood coagulation was investigated by thromboelastometry (TEM) after cardiac surgery and in vitro by use of experimental hemodilution. Materials and methods: Ninety patients scheduled for elective primary cardiac surgery (Studies I, II, IV, V), and twelve healthy volunteers (Study III) were included in this study. After admission to the cardiac surgical intensive care unit (ICU), patients were randomized to receive different doses of HES 130/0.4, HES 200/0.5, or 4% albumin solutions. Ringer’s acetate or albumin solutions served as controls. Coagulation was assessed by TEM, and hemodynamic measurements were based on thermodilutionally measured cardiac index (CI). Results: HES and gelatin solutions impaired whole blood coagulation similarly as measured by TEM even at a small dose of 7 mL/kg. These solutions reduced clot strength and prolonged clot formation time. These effects were more pronounced with increasing doses of colloids. Neither albumin nor Ringer’s acetate solution disturbed blood coagulation significantly. Coagulation disturbances after infusion of HES or gelatin solutions were clinically slight, and postoperative blood loss was comparable with that of Ringer’s acetate or albumin solutions. Both single and multiple doses of all the colloids increased CI postoperatively, and this effect was dose-dependent. Ringer’s acetate had no effect on CI. At a small dose (7 mL/kg), the effect of gelatin on CI was comparable with that of Ringer’s acetate and significantly less than that of HES 130/0.4 (Study V). However, when the dose was increased to 14 and 21 mL/kg, the hemodynamic effect of gelatin rose and became comparable with that of HES 130/0.4. Conclusions: After cardiac surgery, HES and gelatin solutions impaired clot strength in a dose-dependent manner. The potential mechanisms were interaction with fibrinogen and fibrin formation, resulting in decreased clot strength, and hemodilution. Although the use of HES and gelatin inhibited coagulation, postoperative bleeding on the first postoperative morning in all the study groups was similar. A single dose of HES solutions improved CI postoperatively more than did gelatin, albumin, or Ringer’s acetate. However, when administered in a repeated fashion, (cumulative dose of 14 mL/kg or more), no differences were evident between HES 130/0.4 and gelatin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data on the influence of unilateral vocal fold paralysis on breathing, especially other than information obtained by spirometry, are relatively scarce. Even less is known about the effect of its treatment by vocal fold medialization. Consequently, there was a need to study the issue by combining multiple instruments capable of assessing airflow dynamics and voice. This need was emphasized by a recently developed medialization technique, autologous fascia injection; its effects on breathing have not previously been investigated. A cohort of ten patients with unilateral vocal fold paralysis was studied before and after autologous fascia injection by using flow-volume spirometry, body plethysmography and acoustic analysis of breathing and voice. Preoperative results were compared with those of ten healthy controls. A second cohort of 11 subjects with unilateral vocal fold paralysis was studied pre- and postoperatively by using flow-volume spirometry, impulse oscillometry, acoustic analysis of voice, voice handicap index and subjective assessment of dyspnoea. Preoperative peak inspiratory flow and specific airway conductance were significantly lower and airway resistance was significantly higher in the patients than in the healthy controls (78% vs. 107%, 73% vs. 116% and 182% vs. 125% of predicted; p = 0.004, p = 0.004 and p = 0.026, respectively). Patients had a higher root mean square of spectral power of tracheal sounds than controls, and three of them had wheezes as opposed to no wheezing in healthy subjects. Autologous fascia injection significantly improved acoustic parameters of the voice in both cohorts and voice handicap index in the latter cohort, indicating that this procedure successfully improved voice in unilateral vocal fold paralysis. Peak inspiratory flow decreased significantly as a consequence of this procedure (from 4.54 ± 1.68 l to 4.21 ± 1.26 l, p = 0.03, in pooled data of both cohorts), but no change occurred in the other variables of flow-volume spirometry, body-plethysmography and impulse oscillometry. Eight of the ten patients studied by acoustic analysis of breathing had wheezes after vocal fold medialization compared with only three patients before the procedure, and the numbers of wheezes per recorded inspirium and expirium increased significantly (from 0.02 to 0.42 and from 0.03 to 0.36; p = 0.028 and p = 0.043, respectively). In conclusion, unilateral vocal fold paralysis was observed to disturb forced breathing and also to cause some signs of disturbed tidal breathing. Findings of flow volume spirometry were consistent with variable extra-thoracic obstruction. Vocal fold medialization by autologous fascia injection improved the quality of the voice in patients with unilateral vocal fold paralysis, but also decreased peak inspiratory flow and induced wheezing during tidal breathing. However, these airflow changes did not appear to cause significant symptoms in patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Yhteenveto: Järvijään paksuus ja volyymi Suomessa jaksolla 1961-90

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. We estimate the total yearly volume of peer-reviewed scientific journal articles published world-wide as well as the share of these articles available openly on the Web either directly or as copies in e-print repositories. Method. We rely on data from two commercial databases (ISI and Ulrich's Periodicals Directory) supplemented by sampling and Google searches. Analysis. A central issue is the finding that ISI-indexed journals publish far more articles per year (111) than non ISI-indexed journals (26), which means that the total figure we obtain is much lower than many earlier estimates. Our method of analysing the number of repository copies (green open access) differs from several earlier studies which have studied the number of copies in identified repositories, since we start from a random sample of articles and then test if copies can be found by a Web search engine. Results. We estimate that in 2006 the total number of articles published was approximately 1,350,000. Of this number 4.6% became immediately openly available and an additional 3.5% after an embargo period of, typically, one year. Furthermore, usable copies of 11.3% could be found in subject-specific or institutional repositories or on the home pages of the authors. Conclusions. We believe our results are the most reliable so far published and, therefore, should be useful in the on-going debate about Open Access among both academics and science policy makers. The method is replicable and also lends itself to longitudinal studies in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study contributes to the neglect effect literature by looking at the relative trading volume in terms of value. The results for the Swedish market show a significant positive relationship between the accuracy of estimation and the relative trading volume. Market capitalisation and analyst coverage have in prior studies been used as proxies for neglect. These measures however, do not take into account the effort analysts put in when estimating corporate pre-tax profits. I also find evidence that the industry of the firm influence the accuracy of estimation. In addition, supporting earlier findings, loss making firms are associated with larger forecasting errors. Further, I find that the average forecast error increased in the year 2000 – in Sweden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two methods of pre-harvest inventory were designed and tested on three cutting sites containing a total of 197 500 m3 of wood. These sites were located on flat-ground boreal forests located in northwestern Quebec. Both methods studied involved scaling of trees harvested to clear the road path one year (or more) prior to harvest of adjacent cut-blocks. The first method (ROAD) considers the total road right-of-way volume divided by the total road area cleared. The resulting volume per hectare is then multiplied by the total cut-block area scheduled for harvest during the following year to obtain the total estimated cutting volume. The second method (STRATIFIED) also involves scaling of trees cleared from the road. However, in STRATIFIED, log scaling data are stratified by forest stand location. A volume per hectare is calculated for each stretch of road that crosses a single forest stand. This volume per hectare is then multiplied by the remaining area of the same forest stand scheduled for harvest one year later. The sum of all resulting estimated volumes per stand gives the total estimated cutting-volume for all cut-blocks adjacent to the studied road. A third method (MNR) was also used to estimate cut-volumes of the sites studied. This method represents the actual existing technique for estimating cutting volume in the province of Quebec. It involves summing the cut volume for all forest stands. The cut volume is estimated by multiplying the area of each stand by its estimated volume per hectare obtained from standard stock tables provided by the governement. The resulting total estimated volume per cut-block for all three methods was then compared with the actual measured cut-block volume (MEASURED). This analysis revealed a significant difference between MEASURED and MNR methods with the MNR volume estimate being 30 % higher than MEASURED. However, no significant difference from MEASURED was observed for volume estimates for the ROAD and STRATIFIED methods which respectively had estimated cutting volumes 19 % and 5 % lower than MEASURED. Thus the ROAD and STRATIFIED methods are good ways to estimate cut-block volumes after road right-of-way harvest for conditions similar to those examined in this study.