5 resultados para Subjective refraction

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of head-mounted displays (HMDs) can produce both positive and negative experiences. In an effort increase positive experiences and avoid negative ones, researchers have identified a number of variables that may cause sickness and eyestrain, although the exact nature of the relationship to HMDs may vary, depending on the tasks and the environments. Other non-sickness-related aspects of HMDs, such as users opinions and future decisions associated with task enjoyment and interest, have attracted little attention in the research community. In this thesis, user experiences associated with the use of monocular and bi-ocular HMDs were studied. These include eyestrain and sickness caused by current HMDs, the advantages and disadvantages of adjustable HMDs, HMDs as accessories for small multimedia devices, and the impact of individual characteristics and evaluated experiences on reported outcomes and opinions. The results indicate that today s commercial HMDs do not induce serious sickness or eyestrain. Reported adverse symptoms have some influence on HMD-related opinions, but the nature of the impact depends on the tasks and the devices used. As an accessory to handheld devices and as a personal viewing device, HMDs may increase use duration and enable users to perform tasks not suitable for small screens. Well-designed and functional, adjustable HMDs, especially monocular HMDs, increase viewing comfort and usability, which in turn may have a positive effect on product-related satisfaction. The role of individual characteristics in understanding HMD-related experiences has not changed significantly. Explaining other HMD-related experiences, especially forward-looking interests, also requires understanding more stable individual traits and motivations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Refractive errors, especially myopia, seem to increase worldwide. Concurrently, the number of surgical refractive corrections has increased rapidly, with several million procedures performed annually. However, excimer laser surgery was introduced after a limited number of studies done with animals and to date there still are only few long-term follow-up studies of the results. The present thesis aims to evaluate the safety and functional outcome of, as well as to quantify the cellular changes and remodelling in the human cornea after, photorefractive keratectomy (PRK) and laser assisted in situ keratomileusis (LASIK). These procedures are the two most common laser surgical refractive methods. In Study I, myopic ophthalmic residents at Helsinki University Eye Hospital underwent a refractive correction by PRK. Five patients were followed up for 6 months to assess their subjective experience in hospital work and their performance in car driving simulator and in other visuomotor functions. Corneal morphological changes were assessed by in vivo confocal microscopy (ivCM). Study II comprised 14 patients who had undergone a PRK operation in 1993-1994. Visual acuity was examined and ivCM examinations performed 5 years postoperatively. In Study III 15 patients received LASIK refractive correction for moderate to high myopia (-6 - -12 D). Their corneal recovery was followed by ivCM for 2 years. Diffuse lamellar keratitis (DLK) is a common but variable complication of LASIK. Yet, its aetiology remains unknown. In Study IV we examined six patients who had developed DLK as a consequence of formation of an intraoperative or post-LASIK epithelial defect, to assess the corneal and conjunctival inflammatory reaction. In the whole series, the mean refractive correction was -6.46 diopters. The best spectacle corrected visual acuity (BSCVA) improved in 30 % of patients, whereas in four patients BSCVA decreased slightly. The mean achieved refraction was 0.35 D undercorrected. After PRK, the stromal scar formation was highest at 2 to 3 months postoperatively and subsequently decreased. At 5 years increased reflectivity in the subepithelial stroma was observed in all patients. Interestingly, no Bowman s layer was detected in any patient. Subbasal nerve fiber bundle(snfb) regeneration could be observed already at 2 months in 2 patients after PRK. After 5 years, all corneas presented with snfb, the density of which, however, was still lower than in control corneas. LASIK induced a hypocellular area on both sides of the flap interface. A decrease of the most anterior keratocyte density was also observed. In the corneas that developed DLK, inflammatory cell-type objects were present in the flap interface in half of the patients. The other patients presented only with keratocyte activation and highly reflective extracellular matrix. These changes resolved completely with medication and time. Snfb regeneration was first detected at one month post-LASIK, but still after two years the density of snfb, however, was only 64 % of the preoperative values. The performance of ophthalmological examinations and microsurgery without spectacles was easier postoperatively, which was appreciated by the residents. Both PRK and LASIK showed moderate to good accuracy and high safety. In terms of visual perception and subjective evaluation, few patients stated any complaints in the whole series of studies. Instead, the majority of patients experienced a marked improvement in everyday life and work performance. PRK and LASIK have shown similar results, with good long term morphological healing. It seems evident that, even without the benefit of over-20-year follow-up results, these procedures are sufficiently safe and accurate for refractive corrections and corneal reshaping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differentiation of various types of soft tissues is of high importance in medical imaging, because changes in soft tissue structure are often associated with pathologies, such as cancer. However, the densities of different soft tissues may be very similar, making it difficult to distinguish them in absorption images. This is especially true when the consideration of patient dose limits the available signal-to-noise ratio. Refraction is more sensitive than absorption to changes in the density, and small angle x-ray scattering on the other hand contains information about the macromolecular structure of the tissues. Both of these can be used as potential sources of contrast when soft tissues are imaged, but little is known about the visibility of the signals in realistic imaging situations. In this work the visibility of small-angle scattering and refraction in the context of medical imaging has been studied using computational methods. The work focuses on the study of analyzer based imaging, where the information about the sample is recorded in the rocking curve of the analyzer crystal. Computational phantoms based on simple geometrical shapes with differing material properties are used. The objects have realistic dimensions and attenuation properties that could be encountered in real imaging situations. The scattering properties mimic various features of measured small-angle scattering curves. Ray-tracing methods are used to calculate the refraction and attenuation of the beam, and a scattering halo is accumulated, including the effect of multiple scattering. The changes in the shape of the rocking curve are analyzed with different methods, including diffraction enhanced imaging (DEI), extended DEI (E-DEI) and multiple image radiography (MIR). A wide angle DEI, called W-DEI, is introduced and its performance is compared with that of the established methods. The results indicate that the differences in scattered intensities from healthy and malignant breast tissues are distinguishable to some extent with reasonable dose. Especially the fraction of total scattering has large enough differences that it can serve as a useful source of contrast. The peaks related to the macromolecular structure come to angles that are rather large, and have intensities that are only a small fraction of the total scattered intensity. It is found that such peaks seem to have only limited usefulness in medical imaging. It is also found that W-DEI performs rather well when most of the intensity remains in the direct beam, indicating that dark field imaging methods may produce the best results when scattering is weak. Altogether, it is found that the analysis of scattered intensity is a viable option even in medical imaging where the patient dose is the limiting factor.