5 resultados para Skinfold thicknesses

em Helda - Digital Repository of University of Helsinki


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main obstacle for the application of high quality diamond-like carbon (DLC) coatings has been the lack of adhesion to the substrate as the coating thickness is increased. The aim of this study was to improve the filtered pulsed arc discharge (FPAD) method. With this method it is possible to achieve high DLC coating thicknesses necessary for practical applications. The energy of the carbon ions was measured with an optoelectronic time-of-flight method. An in situ cathode polishing system used for stabilizing the process yield and the carbon ion energies is presented. Simultaneously the quality of the coatings can be controlled. To optimise the quality of the deposition process a simple, fast and inexpensive method using silicon wafers as test substrates was developed. This method was used for evaluating the suitability of a simplified arc-discharge set-up for the deposition of the adhesion layer of DLC coatings. A whole new group of materials discovered by our research group, the diamond-like carbon polymer hybrid (DLC-p-h) coatings, is also presented. The parent polymers used in these novel coatings were polydimethylsiloxane (PDMS) and polytetrafluoroethylene (PTFE). The energy of the plasma ions was found to increase when the anode-cathode distance and the arc voltage were increased. A constant deposition rate for continuous coating runs was obtained with an in situ cathode polishing system. The novel DLC-p-h coatings were found to be water and oil repellent and harder than any polymers. The lowest sliding angle ever measured from a solid surface, 0.15 ± 0.03°, was measured on a DLC-PDMS-h coating. In the FPAD system carbon ions can be accelerated to high energies (≈ 1 keV) necessary for the optimal adhesion (the substrate is broken in the adhesion and quality test) of ultra thick (up to 200 µm) DLC coatings by increasing the anode-cathode distance and using high voltages (up to 4 kV). An excellent adhesion can also be obtained with the simplified arc-discharge device. To maintain high process yield (5µm/h over a surface area of 150 cm2) and to stabilize the carbon ion energies and the high quality (sp3 fraction up to 85%) of the resulting coating, an in situ cathode polishing system must be used. DLC-PDMS-h coating is the superior candidate coating material for anti-soiling applications where also hardness is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The incidence of all forms of congenital heart defects is 0.75%. For patients with congenital heart defects, life-expectancy has improved with new treatment modalities. Structural heart defects may require surgical or catheter treatment which may be corrective or palliative. Even those with corrective therapy need regular follow-up due to residual lesions, late sequelae, and possible complications after interventions. Aims: The aim of this thesis was to evaluate cardiac function before and after treatment for volume overload of the right ventricle (RV) caused by atrial septal defect (ASD), volume overload of the left ventricle (LV) caused by patent ductus arteriosus (PDA), and pressure overload of the LV caused by coarctation of the aorta (CoA), and to evaluate cardiac function in patients with Mulibrey nanism. Methods: In Study I, of the 24 children with ASD, 7 underwent surgical correction and 17 percutaneous occlusion of ASD. Study II had 33 patients with PDA undergoing percutaneous occlusion. In Study III, 28 patients with CoA underwent either surgical correction or percutaneous balloon dilatation of CoA. Study IV comprised 26 children with Mulibrey nanism. A total of 76 healthy voluntary children were examined as a control group. In each study, controls were matched to patients. All patients and controls underwent clinical cardiovascular examinations, two-dimensional (2D) and three-dimensional (3D) echocardiographic examinations, and blood sampling for measurement of natriuretic peptides prior to the intervention and twice or three times thereafter. Control children were examined once by 2D and 3D echocardiography. M-mode echocardiography was performed from the parasternal long axis view directed by 2D echocardiography. The left atrium-to-aorta (LA/Ao) ratio was calculated as an index of LA size. The end-diastolic and end-systolic dimensions of LV as well as the end-diastolic thicknesses of the interventricular septum and LV posterior wall were measured. LV volumes, and the fractional shortening (FS) and ejection fraction (EF) as indices of contractility were then calculated, and the z scores of LV dimensions determined. Diastolic function of LV was estimated from the mitral inflow signal obtained by Doppler echocardiography. In three-dimensional echocardiography, time-volume curves were used to determine end-diastolic and end-systolic volumes, stroke volume, and EF. Diastolic and systolic function of LV was estimated from the calculated first derivatives of these curves. Results: (I): In all children with ASD, during the one-year follow-up, the z score of the RV end-diastolic diameter decreased and that of LV increased. However, dilatation of RV did not resolve entirely during the follow-up in either treatment group. In addition, the size of LV increased more slowly in the surgical subgroup but reached control levels in both groups. Concentrations of natriuretic peptides in patients treated percutaneously increased during the first month after ASD closure and normalized thereafter, but in patients treated surgically, they remained higher than in controls. (II): In the PDA group, at baseline, the end-diastolic diameter of LV measured over 2SD in 5 of 33 patients. The median N-terminal pro-brain natriuretic peptide (proBNP) concentration before closure measured 72 ng/l in the control group and 141 ng/l in the PDA group (P = 0.001) and 6 months after closure measured 78.5 ng/l (P = NS). Patients differed from control subjects in indices of LV diastolic and systolic function at baseline, but by the end of follow-up, all these differences had disappeared. Even in the subgroup of patients with normal-sized LV at baseline, the LV end-diastolic volume decreased significantly during follow-up. (III): Before repair, the size and wall thickness of LV were higher in patients with CoA than in controls. Systolic blood pressure measured a median 123 mm Hg in patients before repair (P < 0.001) and 103 mm Hg one year thereafter, and 101 mm Hg in controls. The diameter of the coarctation segment measured a median 3.0 mm at baseline, and 7.9 at the 12-month (P = 0.006) follow-up. Thicknesses of the interventricular septum and posterior wall of the LV decreased after repair but increased to the initial level one year thereafter. The velocity time integrals of mitral inflow increased, but no changes were evident in LV dimensions or contractility. During follow-up, serum levels of natriuretic peptides decreased correlating with diastolic and systolic indices of LV function in 2D and 3D echocardiography. (IV): In 2D echocardiography, the interventricular septum and LV posterior wall were thicker, and velocity time integrals of mitral inflow shorter in patients with Mulibrey nanism than in controls. In 3D echocardiography, LV end-diastolic volume measured a median 51.9 (range 33.3 to 73.4) ml/m² in patients and 59.7 (range 37.6 to 87.6) ml/m² in controls (P = 0.040), and serum levels of ANPN and proBNP a median 0.54 (range 0.04 to 4.7) nmol/l and 289 (range 18 to 9170) ng/l, in patients and 0.28 (range 0.09 to 0.72) nmol/l (P < 0.001) and 54 (range 26 to 139) ng/l (P < 0.001) in controls. They correlated with several indices of diastolic LV function. Conclusions (I): During the one-year follow-up after the ASD closure, RV size decreased but did not normalize in all patients. The size of the LV normalized after ASD closure but the increase in LV size was slower in patients treated surgically than in those treated with the percutaneous technique. Serum levels of ANPN and proBNP were elevated prior to ASD closure but decreased thereafter to control levels in patients treated with the percutaneous technique but not in those treated surgically. (II): Changes in LV volume and function caused by PDA disappeared by 6 months after percutaneous closure. Even the children with normal-sized LV benefited from the procedure. (III): After repair of CoA, the RV size and the velocity time integrals of mitral inflow increased, and serum levels of natriuretic peptides decreased. Patients need close follow-up, despite cessation of LV pressure overload, since LV hypertrophy persisted even in normotensive patients with normal growth of the coarctation segment. (IV): In children with Mulibrey nanism, the LV wall was hypertrophied, with myocardial restriction and impairment of LV function. Significant correlations appeared between indices of LV function, size of the left atrium, and levels of natriuretic peptides, indicating that measurement of serum levels of natriuretic peptides can be used in the clinical follow-up of this patient group despite its dependence on loading conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrophobins are a group of particularly surface active proteins. The surface activity is demonstrated in the ready adsorption of hydrophobins to hydrophobic/hydrophilic interfaces such as the air/water interface. Adsorbed hydrophobins self-assemble into ordered films, lower the surface tension of water, and stabilize air bubbles and foams. Hydrophobin proteins originate from filamentous fungi. In the fungi the adsorbed hydrophobin films enable the growth of fungal aerial structures, form protective coatings and mediate the attachment of fungi to solid surfaces. This thesis focuses on hydrophobins HFBI, HFBII, and HFBIII from a rot fungus Trichoderma reesei. The self-assembled hydrophobin films were studied both at the air/water interface and on a solid substrate. In particular, using grazing-incidence x-ray diffraction and reflectivity, it was possible to characterize the hydrophobin films directly at the air/water interface. The in situ experiments yielded information on the arrangement of the protein molecules in the films. All the T. reesei hydrophobins were shown to self-assemble into highly crystalline, hexagonally ordered rafts. The thicknesses of these two-dimensional protein crystals were below 30 Å. Similar films were also obtained on silicon substrates. The adsorption of the proteins is likely to be driven by the hydrophobic effect, but the self-assembly into ordered films involves also specific protein-protein interactions. The protein-protein interactions lead to differences in the arrangement of the molecules in the HFBI, HFBII, and HFBIII protein films, as seen in the grazing-incidence x-ray diffraction data. The protein-protein interactions were further probed in solution using small-angle x-ray scattering. Both HFBI and HFBII were shown to form mainly tetramers in aqueous solution. By modifying the solution conditions and thereby the interactions, it was shown that the association was due to the hydrophobic effect. The stable tetrameric assemblies could tolerate heating and changes in pH. The stability of the structure facilitates the persistence of these secreted proteins in the soil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis comprises four intercomplementary parts that introduce new approaches to brittle reaction layers and mechanical compatibility of metalloceramic joints created when fusing dental ceramics to titanium. Several different methods including atomic layer deposition (ALD), sessile drop contact angle measurements, scanning acoustic microscopy (SAM), three-point bending (TPB, DIN 13 927 / ISO 9693), cross-section microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS) were employed. The first part investigates the effects of TiO2 layer structure and thickness on the joint strength of the titanium-metalloceramic system. Samples with all tested TiO2 thicknesses displayed good ceramics adhesion to Ti, and uniform TPB results. The fracture mode was independent of oxide layer thickness and structure. Cracking occurred deeper inside titanium, in the oxygen-rich Ti[O]x solid solution surface layer. During dental ceramics firing TiO2 layers dissociate and joints become brittle with increased dissolution of oxygen into metallic Ti and consequent reduction in the metal plasticity. To accomplish an ideal metalloceramic joint this needs to be resolved. The second part introduces photoinduced superhydrophilicity of TiO2. Test samples with ALD deposited anatase TiO2 films were produced. Samples were irradiated with UV light to induce superhydrophilicity of the surfaces through a cascade leading to increased amount of surface hydroxyl groups. Superhydrophilicity (contact angle ~0˚) was achieved within 2 minutes of UV radiation. Partial recovery of the contact angle was observed during the first 10 minutes after UV exposure. Total recovery was not observed within 24h storage. Photoinduced ultrahydrophilicity can be used to enhance wettability of titanium surfaces, an important factor in dental ceramics veneering processes. The third part addresses interlayers designed to restrain oxygen dissolution into Ti during dental ceramics fusing. The main requirements for an ideal interlayer material are proposed. Based on these criteria and systematic exclusion of possible interlayer materials silver (Ag) interlayers were chosen. TPB results were significantly better in when 5 μm Ag interlayers were used compared to only Al2O3-blasted samples. In samples with these Ag interlayers multiple cracks occurred inside dental ceramics, none inside Ti structure. Ag interlayers of 5 μm on Al2O3-blasted samples can be efficiently used to retard formation of the brittle oxygen-rich Ti[O]x layer, thus enhancing metalloceramic joint integrity. The most brittle component in metalloceramic joints with 5 μm Ag interlayers was bulk dental ceramics instead of Ti[O]x. The fourth part investigates the importance of mechanical interlocking. According to the results, the significance of mechanical interlocking achieved by conventional surface treatments can be questioned as long as the formation of the brittle layers (mainly oxygen-rich Ti[O]x) cannot be sufficiently controlled. In summary in contrast to former impressions of thick titanium oxide layers this thesis clearly demonstrates diffusion of oxygen from sintering atmosphere and SiO2 to Ti structures during dental ceramics firing and the following formation of brittle Ti[O]x solid solution as the most important factors predisposing joints between Ti and SiO2-based dental ceramics to low strength. This among other predisposing factors such as residual stresses created by the coefficient of thermal expansion mismatch between dental ceramics and Ti frameworks can be avoided with Ag interlayers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sydämen krooninen vajaatoiminta on merkittävä maailmanlaajuinen ongelma. Se on erilaisten sydän- ja verisuonisairauksien aiheuttama monimuotoinen oireyhtymä. Sydämen vasemman kammion hypertrofia eli sydämen seinämien paksuuntuminen on yksi keskeinen tekijä, joka voi olla sydämen vajaatoiminnan taustalla. Kohonnut verenpaine on yleisin syy, joka johtaa sydänlihaksen paksuuntumiseen. Tämä johtaa sydämen pumppaustoiminnan häiriintymiseen, erilaisten neurohormonaalisten mekanismien aktivaatioon ja edelleen sydämen vajaatoimintaan. Sydämen vajaatoiminnan neurohormonaalisista mekanismeista tärkeimmät ovat reniini-angiotensiini-aldosteroni-järjestelmän ja sympaattisen hermoston aktivaatio, sydämen rakenteiden uudelleenmuovautuminen, sydänlihassolujen apoptoosi ja systeeminen tulehdustila. Sydämen hypertrofiaa ja sen syntymistä pyritään estämään kohonneen verenpaineen lääkehoidolla. Reniini-angiotensiini-aldosteronijärjestelmällä on keskeinen merkitys sydämen vajaatoiminnassa. Sydämen vajaatoiminnan ennusteeseen vaikuttavista lääkeaineista angiotensiinikonvertasin estäjät (ACEestäjät) ovat säilyttäneet johtoasemansa jo vuosikymmenten ajan. Angiotensiinireseptoreiden salpaajien (AT1-salpaajien) odotettiin syrjäyttävän ACE-estäjät sydämen vajaatoiminnan hoidossa, mutta toistaiseksi niitä pidetään vain vaihtoehtoisina lääkkeinä. Sympaattisen hermoston aktivaatiota vähentävät β-salpaajat ovat vakiinnuttaneet asemansa toiseksi tärkeimpänä lääkeryhmänä. Diureetit ovat paljon käytetty lääkeaineryhmä sydämen vajaatoiminnan hoidossa, mutta niistä ainoastaan aldosteroniantagonisteilla on tutkitusti ennustetta parantavaa vaikutusta. Kroonisen vajaatoiminnan hoidossa käytetään edelleen myös digoksiinia. Tulevaisuudessa sydämen vajaatoiminnan ennusteeseen vaikuttavia lääkeaineita voivat olla reniinin estäjät, neutraaliendopeptidaasin estäjät, vasopressiinin antagonistit tai inflammatroisiin sytokiineihin vaikuttavat molekyylit. Erikoistyön kokeellisessa osiossa tarkoituksena oli tutkia sydämen hypertrofian kehittymistä vatsa-aortta kuristetuilla rotilla ja kalsiumherkistäjä levosimendaanin sekä AT1-salpaaja valsartaanin vaikutuksia hypertrofian kehittymiseen. Kokeellisessa osiossa arvioitiin myös sydämen hypertrofian ja vajaatoiminnan jyrsijämallina käytetyn vatsa-aortan kuristuksen (koarktaation) toimivuutta ja vaikutuksia ultraäänen avulla määritettyihin kardiovaskulaarisiin parametreihin. Vatsa-aortta kuristettiin munuaisvaltimoiden yläpuolelta. Kuristus saa aikaan verenpaineen kohoamisen ja sydämen työtaakan lisääntymisen. Pitkittyessään tila johtaa sydänlihaksen hypertrofiaan ja vajaatoimintaan. 64 eläintä jaettiin ryhmiin, siten että jokaiseen ryhmään tuli kahdeksan eläintä. Ryhmistä kolmelle annettiin lääkeaineena levosimendaania kolmella eri päiväannoksella (0,01 mg/kg; 0,10 mg/kg; 1,00 mg/kg) ja kolmelle valsartaania kolmella eri päiväannoksella (0,10 mg/kg; 1,00 mg/kg; 10,00 mg/kg) juomaveden mukana. Lääkitys aloitettiin leikkauksen jälkeen ja jatkettiin kahdeksan viikon ajan. Kardiovaskulaariset parametrit, kuten isovolumetrinen relaksaatioaika (IVRT), vasemman kammion läpimitta systolessa ja diastolessa sekä seinämäpaksuudet, ejektiofraktio (EF), supistuvuusosuus (FS), minuuttitilavuus (CO) ja iskutilavuus (SV) määritettiin kahdeksan viikon kuluttua leikkauksesta ultraäänitutkimuksen avulla. Lisäksi määritettiin eläinten sydämen paino suhteessa ruumiin painoon. Tuloksia verrattiin ilman lääkehoitoa olleeseen koarktaatioryhmään. Eläinmallin toimivuutta arvioitiin vertaamalla koarktaatioryhmän tuloksia sham-operoidun ryhmän tuloksiin. Levosimendaanilla havaittiin työssä sydämen systolista toimintaa parantava vaikutus. Tämä näkyi tendenssinä parantaa ejektiofraktioita ja vasemman kammion supistuvuusosuuksia. Sydämen diastoliseen toimintaan ei kummallakaan lääkeaineella ollut merkittävää vaikutusta. Diastolista toimintaa arvioitiin isovolumetrisen relaksaatioajan muutoksilla. Sydämen hypertrofian kehittymiseen ei kummallakaan lääkeaineella ollut merkittävää vaikutusta. Eläinmallin todettiin mallintavan hyvin sydämen hypetrofiaa ihmisellä, mutta ei niinkään sydämen vajaatoimintaa.