9 resultados para Reproducibility

em Helda - Digital Repository of University of Helsinki


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to improve and continuously develop the quality of pharmaceutical products, the process analytical technology (PAT) framework has been adopted by the US Food and Drug Administration. One of the aims of PAT is to identify critical process parameters and their effect on the quality of the final product. Real time analysis of the process data enables better control of the processes to obtain a high quality product. The main purpose of this work was to monitor crucial pharmaceutical unit operations (from blending to coating) and to examine the effect of processing on solid-state transformations and physical properties. The tools used were near-infrared (NIR) and Raman spectroscopy combined with multivariate data analysis, as well as X-ray powder diffraction (XRPD) and terahertz pulsed imaging (TPI). To detect process-induced transformations in active pharmaceutical ingredients (APIs), samples were taken after blending, granulation, extrusion, spheronisation, and drying. These samples were monitored by XRPD, Raman, and NIR spectroscopy showing hydrate formation in the case of theophylline and nitrofurantoin. For erythromycin dihydrate formation of the isomorphic dehydrate was critical. Thus, the main focus was on the drying process. NIR spectroscopy was applied in-line during a fluid-bed drying process. Multivariate data analysis (principal component analysis) enabled detection of the dehydrate formation at temperatures above 45°C. Furthermore, a small-scale rotating plate device was tested to provide an insight into film coating. The process was monitored using NIR spectroscopy. A calibration model, using partial least squares regression, was set up and applied to data obtained by in-line NIR measurements of a coating drum process. The predicted coating thickness agreed with the measured coating thickness. For investigating the quality of film coatings TPI was used to create a 3-D image of a coated tablet. With this technique it was possible to determine coating layer thickness, distribution, reproducibility, and uniformity. In addition, it was possible to localise defects of either the coating or the tablet. It can be concluded from this work that the applied techniques increased the understanding of physico-chemical properties of drugs and drug products during and after processing. They additionally provided useful information to improve and verify the quality of pharmaceutical dosage forms

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In dentistry, basic imaging techniques such as intraoral and panoramic radiography are in most cases the only imaging techniques required for the detection of pathology. Conventional intraoral radiographs provide images with sufficient information for most dental radiographic needs. Panoramic radiography produces a single image of both jaws, giving an excellent overview of oral hard tissues. Regardless of the technique, plain radiography has only a limited capability in the evaluation of three-dimensional (3D) relationships. Technological advances in radiological imaging have moved from two-dimensional (2D) projection radiography towards digital, 3D and interactive imaging applications. This has been achieved first by the use of conventional computed tomography (CT) and more recently by cone beam CT (CBCT). CBCT is a radiographic imaging method that allows accurate 3D imaging of hard tissues. CBCT has been used for dental and maxillofacial imaging for more than ten years and its availability and use are increasing continuously. However, at present, only best practice guidelines are available for its use, and the need for evidence-based guidelines on the use of CBCT in dentistry is widely recognized. We evaluated (i) retrospectively the use of CBCT in a dental practice, (ii) the accuracy and reproducibility of pre-implant linear measurements in CBCT and multislice CT (MSCT) in a cadaver study, (iii) prospectively the clinical reliability of CBCT as a preoperative imaging method for complicated impacted lower third molars, and (iv) the tissue and effective radiation doses and image quality of dental CBCT scanners in comparison with MSCT scanners in a phantom study. Using CBCT, subjective identification of anatomy and pathology relevant in dental practice can be readily achieved, but dental restorations may cause disturbing artefacts. CBCT examination offered additional radiographic information when compared with intraoral and panoramic radiographs. In terms of the accuracy and reliability of linear measurements in the posterior mandible, CBCT is comparable to MSCT. CBCT is a reliable means of determining the location of the inferior alveolar canal and its relationship to the roots of the lower third molar. CBCT scanners provided adequate image quality for dental and maxillofacial imaging while delivering considerably smaller effective doses to the patient than MSCT. The observed variations in patient dose and image quality emphasize the importance of optimizing the imaging parameters in both CBCT and MSCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the past ten years, large-scale transcript analysis using microarrays has become a powerful tool to identify and predict functions for new genes. It allows simultaneous monitoring of the expression of thousands of genes and has become a routinely used tool in laboratories worldwide. Microarray analysis will, together with other functional genomics tools, take us closer to understanding the functions of all genes in genomes of living organisms. Flower development is a genetically regulated process which has mostly been studied in the traditional model species Arabidopsis thaliana, Antirrhinum majus and Petunia hybrida. The molecular mechanisms behind flower development in them are partly applicable in other plant systems. However, not all biological phenomena can be approached with just a few model systems. In order to understand and apply the knowledge to ecologically and economically important plants, other species also need to be studied. Sequencing of 17 000 ESTs from nine different cDNA libraries of the ornamental plant Gerbera hybrida made it possible to construct a cDNA microarray with 9000 probes. The probes of the microarray represent all different ESTs in the database. From the gerbera ESTs 20% were unique to gerbera while 373 were specific to the Asteraceae family of flowering plants. Gerbera has composite inflorescences with three different types of flowers that vary from each other morphologically. The marginal ray flowers are large, often pigmented and female, while the central disc flowers are smaller and more radially symmetrical perfect flowers. Intermediate trans flowers are similar to ray flowers but smaller in size. This feature together with the molecular tools applied to gerbera, make gerbera a unique system in comparison to the common model plants with only a single kind of flowers in their inflorescence. In the first part of this thesis, conditions for gerbera microarray analysis were optimised including experimental design, sample preparation and hybridization, as well as data analysis and verification. Moreover, in the first study, the flower and flower organ-specific genes were identified. After the reliability and reproducibility of the method were confirmed, the microarrays were utilized to investigate transcriptional differences between ray and disc flowers. This study revealed novel information about the morphological development as well as the transcriptional regulation of early stages of development in various flower types of gerbera. The most interesting finding was differential expression of MADS-box genes, suggesting the existence of flower type-specific regulatory complexes in the specification of different types of flowers. The gerbera microarray was further used to profile changes in expression during petal development. Gerbera ray flower petals are large, which makes them an ideal model to study organogenesis. Six different stages were compared and specifically analysed. Expression profiles of genes related to cell structure and growth implied that during stage two, cells divide, a process which is marked by expression of histones, cyclins and tubulins. Stage 4 was found to be a transition stage between cell division and expansion and by stage 6 cells had stopped division and instead underwent expansion. Interestingly, at the last analysed stage, stage 9, when cells did not grow any more, the highest number of upregulated genes was detected. The gerbera microarray is a fully-functioning tool for large-scale studies of flower development and correlation with real-time RT-PCR results show that it is also highly sensitive and reliable. Gene expression data presented here will be a source for gene expression mining or marker gene discovery in the future studies that will be performed in the Gerbera Laboratory. The publicly available data will also serve the plant research community world-wide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atrial fibrillation is the most common arrhythmia requiring treatment. This Thesis investigated atrial fibrillation (AF) with a specific emphasis on atrial remodeling which was analysed from epidemiological, clinical and magnetocardiographic (MCG) perspectives. In the first study we evaluated in real-life clinical practice a population-based cohort of AF patients referred for their first elective cardioversion (CV). 183 consecutive patients were included of whom in 153 (84%) sinus rhythm (SR) was restored. Only 39 (25%) of those maintained SR for one year. Shorter duration of AF and the use of sotalol were the only characteristics associated with better restoration and maintenance of SR. During the one-year follow-up 40% of the patients ended up in permanent AF. Female gender and older age were associated with the acceptance of permanent AF. The LIFE-trial was a prospective, randomised, double-blinded study that evaluated losartan and atenolol in patients with hypertension and left ventricular hypertrophy (LVH). Of the 8,851 patients with SR at baseline and without a history of AF 371 patients developed new-onset AF during the study. Patients with new-onset AF had an increased risk of cardiac events, stroke, and increased rate of hospitalisation for heart failure. Younger age, female gender, lower systolic blood pressure, lesser LVH in ECG and randomisation to losartan therapy were independently associated with lower frequency of new-onset AF. The impact of AF on morbidity and mortality was evaluated in a post-hoc analysis of the OPTIMAAL trial that compared losartan with captopril in patients with acute myocardial infarction (AMI) and evidence of LV dysfunction. Of the 5,477 randomised patients 655 had AF at baseline, and 345 patients developed new AF during the follow-up period, median 3.0 years. Older patients and patients with signs of more serious heart disease had and developed AF more often. Patients with AF at baseline had an increased risk of mortality (hazard ratio (HR) of 1.32) and stroke (HR 1.77). New-onset AF was associated with increased mortality (HR 1.82) and stroke (HR of 2.29). In the fourth study we assessed the reproducibility of our MCG method. This method was used in the fifth study where 26 patients with persistent AF had immediately after the CV longer P-wave duration and higher energy of the last portion of atrial signal (RMS40) in MCG, increased P-wave dispersion in SAECG and decreased pump function of the atria as well as enlarged atrial diameter in echocardiography compared to age- and disease-matched controls. After one month in SR, P-wave duration in MCG still remained longer and left atrial (LA) diameter greater compared to the controls, while the other measurements had returned to the same level as in the control group. In conclusion is not a rare condition in either general population or patients with hypertension or AMI, and it is associated with increased risk of morbidity and mortality. Therefore, atrial remodeling that increases the likelihood of AF and also seems to be relatively stable has to be identified and prevented. MCG was found to be an encouraging new method to study electrical atrial remodeling and reverse remodeling. RAAS-suppressing medications appear to be the most promising method to prevent atrial remodeling and AF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MEG directly measures the neuronal events and has greater temporal resolution than fMRI, which has limited temporal resolution mainly due to the larger timescale of the hemodynamic response. On the other hand fMRI has advantages in spatial resolution, while the localization results with MEG can be ambiguous due to the non-uniqueness of the electromagnetic inverse problem. Thus, these methods could provide complementary information and could be used to create both spatially and temporally accurate models of brain function. We investigated the degree of overlap, revealed by the two imaging methods, in areas involved in sensory or motor processing in healthy subjects and neurosurgical patients. Furthermore, we used the spatial information from fMRI to construct a spatiotemporal model of the MEG data in order to investigate the sensorimotor system and to create a spatiotemporal model of its function. We compared the localization results from the MEG and fMRI with invasive electrophysiological cortical mapping. We used a recently introduced method, contextual clustering, for hypothesis testing of fMRI data and assessed the the effect of neighbourhood information use on the reproducibility of fMRI results. Using MEG, we identified the ipsilateral primary sensorimotor cortex (SMI) as a novel source area contributing to the somatosensory evoked fields (SEF) to median nerve stimulation. Using combined MEG and fMRI measurements we found that two separate areas in the lateral fissure may be the generators for the SEF responses from the secondary somatosensory cortex region. The two imaging methods indicated activation in corresponding locations. By using complementary information from MEG and fMRI we established a spatiotemporal model of somatosensory cortical processing. This spatiotemporal model of cerebral activity was in good agreement with results from several studies using invasive electrophysiological measurements and with anatomical studies in monkey and man concerning the connections between somatosensory areas. In neurosurgical patients, the MEG dipole model turned out to be more reliable than fMRI in the identification of the central sulcus. This was due to prominent activation in non-primary areas in fMRI, which in some cases led to erroneous or ambiguous localization of the central sulcus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Airway inflammation is a key feature of bronchial asthma. In asthma management, according to international guidelines, the gold standard is anti-inflammatory treatment. Currently, only conventional procedures (i.e., symptoms, use of rescue medication, PEF-variability, and lung function tests) were used to both diagnose and evaluate the results of treatment with anti-inflammatory drugs. New methods for evaluation of degree of airway inflammation are required. Nitric oxide (NO) is a gas which is produced in the airways of healthy subjects and especially produced in asthmatic airways. Measurement of NO from the airways is possible, and NO can be measured from exhaled air. Fractional exhaled NO (FENO) is increased in asthma, and the highest concentrations are measured in asthmatic patients not treated with inhaled corticosteroids (ICS). Steroid-treated patients with asthma had levels of FENO similar to those of healthy controls. Atopic asthmatics had higher levels of FENO than did nonatopic asthmatics, indicating that level of atopy affected FENO level. Associations between FENO and bronchial hyperresponsiveness (BHR) occur in asthma. The present study demonstrated that measurement of FENO had good reproducibility, and the FENO variability was reasonable both short- and long-term in both healthy subjects and patients with respiratory symptoms or asthma. We demonstrated the upper normal limit for healthy subjects, which was 12 ppb calculated from two different healthy study populations. We showed that patients with respiratory symptoms who did not fulfil the diagnostic criteria of asthma had FENO values significantly higher than in healthy subjects, but significantly lower than in asthma patients. These findings suggest that BHR to histamine is a sensitive indicator of the effect of ICS and a valuable tool for adjustment of corticosteroid treatment in mild asthma. The findings further suggest that intermittent treatment periods of a few weeks’ duration are insufficient to provide long-term control of BHR in patients with mild persistent asthma. Moreover, during the treatment with ICS changes in BHR and changes in FENO were associated. FENO level was associated with BHR measured by a direct (histamine challenge) or indirect method (exercise challenge) in steroid-naïve symptomatic, non-smoking asthmatics. Although these associations could be found only in atopics, FENO level in nonatopic asthma was also increased. It can thus be concluded that assessment of airway inflammation by measuring FENO can be useful for clinical purposes. The methodology of FENO measurements is now validated. Especially in those patients with respiratory symptoms who did not fulfil the diagnostic criteria of asthma, FENO measurement can aid in treatment decisions. Serial measurement of FENO during treatment with ICS can be a complementary or an alternative method for evaluation in patients with asthma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiation therapy (RT) plays currently significant role in curative treatments of several cancers. External beam RT is carried out mostly by using megavoltage beams of linear accelerators. Tumor eradication and normal tissue complications correlate to dose absorbed in tissues. Normally this dependence is steep and it is crucial that actual dose within patient accurately correspond to the planned dose. All factors in a RT procedure contain uncertainties requiring strict quality assurance. From hospital physicist´s point of a view, technical quality control (QC), dose calculations and methods for verification of correct treatment location are the most important subjects. Most important factor in technical QC is the verification that radiation production of an accelerator, called output, is within narrow acceptable limits. The output measurements are carried out according to a locally chosen dosimetric QC program defining measurement time interval and action levels. Dose calculation algorithms need to be configured for the accelerators by using measured beam data. The uncertainty of such data sets limits for best achievable calculation accuracy. All these dosimetric measurements require good experience, are workful, take up resources needed for treatments and are prone to several random and systematic sources of errors. Appropriate verification of treatment location is more important in intensity modulated radiation therapy (IMRT) than in conventional RT. This is due to steep dose gradients produced within or close to healthy tissues locating only a few millimetres from the targeted volume. The thesis was concentrated in investigation of the quality of dosimetric measurements, the efficacy of dosimetric QC programs, the verification of measured beam data and the effect of positional errors on the dose received by the major salivary glands in head and neck IMRT. A method was developed for the estimation of the effect of the use of different dosimetric QC programs on the overall uncertainty of dose. Data were provided to facilitate the choice of a sufficient QC program. The method takes into account local output stability and reproducibility of the dosimetric QC measurements. A method based on the model fitting of the results of the QC measurements was proposed for the estimation of both of these factors. The reduction of random measurement errors and optimization of QC procedure were also investigated. A method and suggestions were presented for these purposes. The accuracy of beam data was evaluated in Finnish RT centres. Sufficient accuracy level was estimated for the beam data. A method based on the use of reference beam data was developed for the QC of beam data. Dosimetric and geometric accuracy requirements were evaluated for head and neck IMRT when function of the major salivary glands is intended to be spared. These criteria are based on the dose response obtained for the glands. Random measurement errors could be reduced enabling lowering of action levels and prolongation of measurement time interval from 1 month to even 6 months simultaneously maintaining dose accuracy. The combined effect of the proposed methods, suggestions and criteria was found to facilitate the avoidance of maximal dose errors of up to even about 8 %. In addition, their use may make the strictest recommended overall dose accuracy level of 3 % (1SD) achievable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Väärinkäytettyjen aineiden seulontaan käytetyn menetelmän tulee olla herkkä, selektiivinen, yksinkertainen, nopea ja toistettava. Työn tavoitteena oli kehittää yksinkertainen, mutta herkkä, esikäsittelymenetelmä bentsodiatsepiinien ja amfetamiinijohdannaisten kvalitatiiviseen seulomiseen virtsasta mikropilarisähkösumutussirun (μPESI) avulla, mikä tarjoaisi vaihtoehdon seulonnassa käytetyille immunologisille menetelmille, joiden herkkyys ja selektiivisyys ovat puutteellisia. Tavoitteena oli samalla tarkastella mikropilarisähkösumutussirun toimivuutta biologisten näytteiden analyysissa. Esikäsittely optimoitiin erikseen bentsodiatsepiineille ja amfetamiinijohdannaisille. Käytettyjä esikäsittelymenetelmiä olivat neste-nesteuutto, kiinteäfaasiuutto Oasis HLB-patruunalla ja ZipTip®-pipetinkärjellä sekä laimennus ja suodatus ilman uuttoa. Mittausten perusteella keskityttiin optimoimaan ZipTip®-uuttoa. Optimoinnissa tutkittavia yhdisteitä spiikattiin 0-virtsaan niiden ennaltamääritetyn raja-arvon verran, bentsodiatsepiineja 200 ng/ml ja amfetamiinijohdannaisia 300 ng/ml. Bentsodiatsepiinien kohdalla optimoitiin kutakin uuton vaihetta ja optimoinnin tuloksena näytteen pH säädettiin arvoon 5, faasi kunnostettiin asetonitriililla, tasapainotettiin ja pestiin veden (pH 5) ja asetonitriilin (10 % v/v) seoksella ja eluoitiin asetonitriilin, muurahaishapon ja veden (95:1:4 v/v/v) seoksella. Amfetamiinijohdannaisten uutossa optimoitiin näytteen ja liuottimien pH-arvoja ja tuloksena näytteen pH säädettiin arvoon 10, faasi kunnostettiin veden ja ammoniumvetykarbonaatin(pH 10, 1:1 v/v) seoksella, tasapainotettiin ja pestiin asetonitriilin ja veden (1:5 v/v) seoksella ja eluoitiin metanolilla. Optimoituja uuttoja testattiin Yhtyneet Medix Laboratorioista toimitetuilla autenttisilla virtsanäytteillä ja saatuja tuloksia verrattiin kvantitatiivisen GC/MS-analyysin tuloksiin. Bentsodiatsepiininäytteet hydrolysoitiin ennen uuttoa herkkyyden parantamiseksi. Autenttiset näytteet analysoitiin Q-TOF-laitteella Viikissä. Lisäksi hydrolysoidut bentsodiatsepiininäytteet mitattiin Yhtyneet Medix Laboratorioiden TOF-laitteella. Kehitetty menetelmä vaatii tulosten perusteella lisää optimointia toimiakseen. Ongelmana oli etenkin toistoissa ilmennyt tulosten hajonta. Manuaalista näytteensyöttöä tulisi kehittää toistettavammaksi. Autenttisten bentsodiatsepiininäytteiden analyysissa ongelmana olivat virheelliset negatiiviset tulokset ja amfetamiinijohdannaisten analyysissa virheelliset positiiviset tulokset. Virheellisiä negatiivisia tuloksia selittää menetelmän herkkyyden puute ja virheellisiä positiivisia tuloksia mittalaitteen, sirujen tai liuottimien likaantuminen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A better understanding of vacuum arcs is desirable in many of today's 'big science' projects including linear colliders, fusion devices, and satellite systems. For the Compact Linear Collider (CLIC) design, radio-frequency (RF) breakdowns occurring in accelerating cavities influence efficiency optimisation and cost reduction issues. Studying vacuum arcs both theoretically as well as experimentally under well-defined and reproducible direct-current (DC) conditions is the first step towards exploring RF breakdowns. In this thesis, we have studied Cu DC vacuum arcs with a combination of experiments, a particle-in-cell (PIC) model of the arc plasma, and molecular dynamics (MD) simulations of the subsequent surface damaging mechanism. We have also developed the 2D Arc-PIC code and the physics model incorporated in it, especially for the purpose of modelling the plasma initiation in vacuum arcs. Assuming the presence of a field emitter at the cathode initially, we have identified the conditions for plasma formation and have studied the transitions from field emission stage to a fully developed arc. The 'footing' of the plasma is the cathode spot that supplies the arc continuously with particles; the high-density core of the plasma is located above this cathode spot. Our results have shown that once an arc plasma is initiated, and as long as energy is available, the arc is self-maintaining due to the plasma sheath that ensures enhanced field emission and sputtering. The plasma model can already give an estimate on how the time-to-breakdown changes with the neutral evaporation rate, which is yet to be determined by atomistic simulations. Due to the non-linearity of the problem, we have also performed a code-to-code comparison. The reproducibility of plasma behaviour and time-to-breakdown with independent codes increased confidence in the results presented here. Our MD simulations identified high-flux, high-energy ion bombardment as a possible mechanism forming the early-stage surface damage in vacuum arcs. In this mechanism, sputtering occurs mostly in clusters, as a consequence of overlapping heat spikes. Different-sized experimental and simulated craters were found to be self-similar with a crater depth-to-width ratio of about 0.23 (sim) - 0.26 (exp). Experiments, which we carried out to investigate the energy dependence of DC breakdown properties, point at an intrinsic connection between DC and RF scaling laws and suggest the possibility of accumulative effects influencing the field enhancement factor.