6 resultados para ROTATING SPIRALS

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis we examine multi-field inflationary models of the early Universe. Since non-Gaussianities may allow for the possibility to discriminate between models of inflation, we compute deviations from a Gaussian spectrum of primordial perturbations by extending the delta-N formalism. We use N-flation as a concrete model; our findings show that these models are generically indistinguishable as long as the slow roll approximation is still valid. Besides computing non-Guassinities, we also investigate Preheating after multi-field inflation. Within the framework of N-flation, we find that preheating via parametric resonance is suppressed, an indication that it is the old theory of preheating that is applicable. In addition to studying non-Gaussianities and preheatng in multi-field inflationary models, we study magnetogenesis in the early universe. To this aim, we propose a mechanism to generate primordial magnetic fields via rotating cosmic string loops. Magnetic fields in the micro-Gauss range have been observed in galaxies and clusters, but their origin has remained elusive. We consider a network of strings and find that rotating cosmic string loops, which are continuously produced in such networks, are viable candidates for magnetogenesis with relevant strength and length scales, provided we use a high string tension and an efficient dynamo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to improve and continuously develop the quality of pharmaceutical products, the process analytical technology (PAT) framework has been adopted by the US Food and Drug Administration. One of the aims of PAT is to identify critical process parameters and their effect on the quality of the final product. Real time analysis of the process data enables better control of the processes to obtain a high quality product. The main purpose of this work was to monitor crucial pharmaceutical unit operations (from blending to coating) and to examine the effect of processing on solid-state transformations and physical properties. The tools used were near-infrared (NIR) and Raman spectroscopy combined with multivariate data analysis, as well as X-ray powder diffraction (XRPD) and terahertz pulsed imaging (TPI). To detect process-induced transformations in active pharmaceutical ingredients (APIs), samples were taken after blending, granulation, extrusion, spheronisation, and drying. These samples were monitored by XRPD, Raman, and NIR spectroscopy showing hydrate formation in the case of theophylline and nitrofurantoin. For erythromycin dihydrate formation of the isomorphic dehydrate was critical. Thus, the main focus was on the drying process. NIR spectroscopy was applied in-line during a fluid-bed drying process. Multivariate data analysis (principal component analysis) enabled detection of the dehydrate formation at temperatures above 45°C. Furthermore, a small-scale rotating plate device was tested to provide an insight into film coating. The process was monitored using NIR spectroscopy. A calibration model, using partial least squares regression, was set up and applied to data obtained by in-line NIR measurements of a coating drum process. The predicted coating thickness agreed with the measured coating thickness. For investigating the quality of film coatings TPI was used to create a 3-D image of a coated tablet. With this technique it was possible to determine coating layer thickness, distribution, reproducibility, and uniformity. In addition, it was possible to localise defects of either the coating or the tablet. It can be concluded from this work that the applied techniques increased the understanding of physico-chemical properties of drugs and drug products during and after processing. They additionally provided useful information to improve and verify the quality of pharmaceutical dosage forms

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Comprehensive two-dimensional gas chromatography (GC×GC) offers enhanced separation efficiency, reliability in qualitative and quantitative analysis, capability to detect low quantities, and information on the whole sample and its components. These features are essential in the analysis of complex samples, in which the number of compounds may be large or the analytes of interest are present at trace level. This study involved the development of instrumentation, data analysis programs and methodologies for GC×GC and their application in studies on qualitative and quantitative aspects of GC×GC analysis. Environmental samples were used as model samples. Instrumental development comprised the construction of three versions of a semi-rotating cryogenic modulator in which modulation was based on two-step cryogenic trapping with continuously flowing carbon dioxide as coolant. Two-step trapping was achieved by rotating the nozzle spraying the carbon dioxide with a motor. The fastest rotation and highest modulation frequency were achieved with a permanent magnetic motor, and modulation was most accurate when the motor was controlled with a microcontroller containing a quartz crystal. Heated wire resistors were unnecessary for the desorption step when liquid carbon dioxide was used as coolant. With use of the modulators developed in this study, the narrowest peaks were 75 ms at base. Three data analysis programs were developed allowing basic, comparison and identification operations. Basic operations enabled the visualisation of two-dimensional plots and the determination of retention times, peak heights and volumes. The overlaying feature in the comparison program allowed easy comparison of 2D plots. An automated identification procedure based on mass spectra and retention parameters allowed the qualitative analysis of data obtained by GC×GC and time-of-flight mass spectrometry. In the methodological development, sample preparation (extraction and clean-up) and GC×GC methods were developed for the analysis of atmospheric aerosol and sediment samples. Dynamic sonication assisted extraction was well suited for atmospheric aerosols collected on a filter. A clean-up procedure utilising normal phase liquid chromatography with ultra violet detection worked well in the removal of aliphatic hydrocarbons from a sediment extract. GC×GC with flame ionisation detection or quadrupole mass spectrometry provided good reliability in the qualitative analysis of target analytes. However, GC×GC with time-of-flight mass spectrometry was needed in the analysis of unknowns. The automated identification procedure that was developed was efficient in the analysis of large data files, but manual search and analyst knowledge are invaluable as well. Quantitative analysis was examined in terms of calibration procedures and the effect of matrix compounds on GC×GC separation. In addition to calibration in GC×GC with summed peak areas or peak volumes, simplified area calibration based on normal GC signal can be used to quantify compounds in samples analysed by GC×GC so long as certain qualitative and quantitative prerequisites are met. In a study of the effect of matrix compounds on GC×GC separation, it was shown that quality of the separation of PAHs is not significantly disturbed by the amount of matrix and quantitativeness suffers only slightly in the presence of matrix and when the amount of target compounds is low. The benefits of GC×GC in the analysis of complex samples easily overcome some minor drawbacks of the technique. The developed instrumentation and methodologies performed well for environmental samples, but they could also be applied for other complex samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A total of 177 patients with primary dislocation of the patella (PDP) were admitted to two trauma centers in Helsinki, Finland during 1991 to 1992. The inclusion criteria were: 1. Acute (≤14 days old) first-time lateral dislocation of the patella. 2. No previous knee operations or major knee injuries. 3. No ligament injuries to be repaired. 4. No osteochondral fractures requiring fixation. 50 patients were excluded. 30 of these excluded patients would have met the inclusion criteria, 19 patients received treatment by consultants not involved in the study, 7 refused to participate and 4 had an erroneous randomization. 127 patients including, 82 females, were then randomized to have either tailor-made operative procedure (group O) or conservative treatment (group C). The aftercare was similar for both groups. The mean age of the patients was 20 (9-47) years. All patients were subjected to analysis of trauma history (starting position and knee movement during the dislocation), examination under anesthesia (EUA) and arthroscopy. 70 patients (52 females) were randomized by their odd year of birth to operative group O and 57 patients (30 females) by their even year of birth to conservative group C. The diagnosis of PDP was based on locked dislocation in 68 patients, on dislocatability in EUA in 47 patients, and on subluxation in EUA combined with typical intra-articular lesions in 12 patients. In group O, 63 patients had exploration of the injuries on the medial side of the knee and tailor made reconstruction added with lateral release in 54 cases. The medial injury was operated by suturing in 39 patients, by duplication in 18 patients and by additional augmentation of the medial patellofemoral ligament (MPFL) with adductor magnus tenodesis in 6 patients. 7 patients, without locking in trauma history and only subluxation in EUA had only lateral release for realignment. In adductor magnus tenodesis the proximal end of the distal tendinous part was rerouted to the upper medial border of the patella. In the conservative group C, the treatment was adjusted to the extent of patellar displacement in EUA. Patients with dislocation in EUA had 3 weeks’ immobilization with the knee in slight flexion. Mobilization was started with a soft patellar stabilizing orthosis (PSO) used for additional three weeks. The patients with subluxation in EUA wore an orthosis for six weeks. The aftercare was similar in group O. The outcome was similar in both groups. After an average of 25 (20-45) months´ follow-up, the subjective result was better in group C in respect of the mean Hughston VAS knee score (87 for group O and 90 for group C, p=0.04, visual analog scale), but similar in terms of the patient’s own overall opinion and the mean Lysholm II knee score. Recurrent instability episodes occurred in 18 patients in group O and in 20 patients in group C. After an average of 7 (6-9) years´ follow-up, the groups did not show statistical difference either in respect of the patient’s own overall opinion, or the mean Hughston VAS and Kujala knee scores. The proportions of stable patellae was 25/70 (36%) in group O and 17/57 (30%) in group O (p=0.5). In a multivariate risk analysis, there was a correlation between low Kujala score (<90) as dependent parameter and female gender (OR: 3.5; 95% CI: 1.4-9.0), and loose body on primary radiographs (OR: 4.1; 95% CI: 1.2-15). Recurrent instability correlated with young age at the time of PDP (OR: 0.9; 95% CI: 0.8-1.0/year). Girls with open tibial apophysis had the worst prognosis for instability (88%; 95% CI: 77-98). The most common mechanisms in trauma history of the patients were movement to flexion from a straight start (78%) and movement to extension from a well-bent start (8%). Spontaneous relocation of the patella had taken place in 13/39 of girls, in 11/21 of boys, in 26/42 of women and in 17/24 of men with skeletal maturity of the tibia. The dislocation in EUA was non-rotating in 96/126 patients followed by outward rotating dislocation in 14/126 patients. Operative treatment policy in PDP is not recommended. Locking tendency of the patella in PDP depended on the skeletal maturation. Recurrence rate after PDP was higher than expected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This qualitative, explorative study, which comprises four essays, focuses on knowledge management (KM). It seeks to answer the question: How can the knowledge creation theory of KM benefit from social learning theories? While studying the five development phases of knowledge creation theory of KM through 1995-2008 and applying some social learning theories in essays, the concepts of knowing, learning and becoming have emerged. Drawing on these three concepts and on becoming ontology and extended epistemology as research philosophies the study suggests the ‘becoming epistemology’ concept and develops the ‘becoming to know’ framework. The framework proposes becoming as phronesis of dialectic interactions between learning and knowing. It shows how becoming to know evolves as an interplay between concrete experience and logical thinking in the present and in a living context. The proposed framework could be considered a contribution to the current development phase of the knowledge creation theory of KM because it illustrates how ontological and epistemological knowledge spirals come together, which is the essence of the knowledge creation theory of KM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation deals with the design, fabrication, and applications of microscale electrospray ionization chips for mass spectrometry. The microchip consists of microchannel, which leads to a sharp electrospray tip. Microchannel contain micropillars that facilitate a powerful capillary action in the channels. The capillary action delivers the liquid sample to the electrospray tip, which sprays the liquid sample to gas phase ions that can be analyzed with mass spectrometry. The microchip uses a high voltage, which can be utilized as a valve between the microchip and mass spectrometry. The microchips can be used in various applications, such as for analyses of drugs, proteins, peptides, or metabolites. The microchip works without pumps for liquid transfer, is usable for rapid analyses, and is sensitive. The characteristics of performance of the single microchips are studied and a rotating multitip version of the microchips are designed and fabricated. It is possible to use the microchip also as a microreactor and reaction products can be detected online with mass spectrometry. This property can be utilized for protein identification for example. Proteins can be digested enzymatically on-chip and reaction products, which are in this case peptides, can be detected with mass spectrometry. Because reactions occur faster in a microscale due to shorter diffusion lengths, the amount of protein can be very low, which is a benefit of the method. The microchip is well suited to surface activated reactions because of a high surface-to-volume ratio due to a dense micropillar array. For example, titanium dioxide nanolayer on the micropillar array combined with UV radiation produces photocatalytic reactions which can be used for mimicking drug metabolism biotransformation reactions. Rapid mimicking with the microchip eases the detection of possibly toxic compounds in preclinical research and therefore could speed up the research of new drugs. A micropillar array chip can also be utilized in the fabrication of liquid chromatographic columns. Precisely ordered micropillar arrays offer a very homogenous column, where separation of compounds has been demonstrated by using both laser induced fluorescence and mass spectrometry. Because of small dimensions on the microchip, the integrated microchip based liquid chromatography electrospray microchip is especially well suited to low sample concentrations. Overall, this work demonstrates that the designed and fabricated silicon/glass three dimensionally sharp electrospray tip is unique and facilitates stable ion spray for mass spectrometry.