Resumo:

The majority of Internet traffic use Transmission Control Protocol (TCP) as the transport level protocol. It provides a reliable ordered byte stream for the applications. However, applications such as live video streaming place an emphasis on timeliness over reliability. Also a smooth sending rate can be desirable over sharp changes in the sending rate. For these applications TCP is not necessarily suitable. Rate control attempts to address the demands of these applications. An important design feature in all rate control mechanisms is TCP friendliness. We should not negatively impact TCP performance since it is still the dominant protocol. Rate Control mechanisms are classified into two different mechanisms: window-based mechanisms and rate-based mechanisms. Window-based mechanisms increase their sending rate after a successful transfer of a window of packets similar to TCP. They typically decrease their sending rate sharply after a packet loss. Rate-based solutions control their sending rate in some other way. A large subset of rate-based solutions are called equation-based solutions. Equation-based solutions have a control equation which provides an allowed sending rate. Typically these rate-based solutions react slower to both packet losses and increases in available bandwidth making their sending rate smoother than that of window-based solutions. This report contains a survey of rate control mechanisms and a discussion of their relative strengths and weaknesses. A section is dedicated to a discussion on the enhancements in wireless environments. Another topic in the report is bandwidth estimation. Bandwidth estimation is divided into capacity estimation and available bandwidth estimation. We describe techniques that enable the calculation of a fair sending rate that can be used to create novel rate control mechanisms.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Inter-enterprise collaboration has become essential for the success of enterprises. As competition increasingly takes place between supply chains and networks of enterprises, there is a strategic business need to participate in multiple collaborations simultaneously. Collaborations based on an open market of autonomous actors set special requirements for computing facilities supporting the setup and management of these business networks of enterprises. Currently, the safeguards against privacy threats in collaborations crossing organizational borders are both insufficient and incompatible to the open market. A broader understanding is needed of the architecture of defense structures, and privacy threats must be detected not only on the level of a private person or enterprise, but on the community and ecosystem levels as well. Control measures must be automated wherever possible in order to keep the cost and effort of collaboration management reasonable. This article contributes to the understanding of the modern inter-enterprise collaboration environment and privacy threats in it, and presents the automated control measures required to ensure that actors in inter-enterprise collaborations behave correctly to preserve privacy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction This case study is based on the experiences with the Electronic Journal of Information Technology in Construction (ITcon), founded in 1995. Development This journal is an example of a particular category of open access journals, which use neither author charges nor subscriptions to finance their operations, but rely largely on unpaid voluntary work in the spirit of the open source movement. The journal has, after some initial struggle, survived its first decade and is now established as one of half-a-dozen peer reviewed journals in its field. Operations The journal publishes articles as they become ready, but creates virtual issues through alerting messages to “subscribers”. It has also started to publish special issues, since this helps in attracting submissions, and also helps in sharing the work-load of review management. From the start the journal adopted a rather traditional layout of the articles. After the first few years the HTML version was dropped and papers are only published in PDF format. Performance The journal has recently been benchmarked against the competing journals in its field. Its acceptance rate of 53% is slightly higher and its average turnaround time of seven months almost a year faster compared to those journals in the sample for which data could be obtained. The server log files for the past three years have also been studied. Conclusions Our overall experience demonstrates that it is possible to publish this type of OA journal, with a yearly publishing volume equal to a quarterly journal and involving the processing of some fifty submissions a year, using a networked volunteer-based organization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.