5 resultados para OXIDE GAS SENSORS

em Helda - Digital Repository of University of Helsinki


Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is essential to have a thorough understanding of the sources and sinks of oxidized nitrogen (NOy) in the atmosphere, since it has a strong influence on the tropospheric chemistry and the eutrophication of ecosystems. One unknown component in the balance of gaseous oxidized nitrogen is vegetation. Plants absorb nitrogenous species from the air via the stomata, but it is not clear whether plants can also emit them at low ambient concentrations. The possible emissions are small and difficult to measure. The aim of this thesis was to analyse an observation made in southern Finland at the SMEAR II station: solar ultraviolet radiation (UV) induced NOy emissions in chambers measuring the gas exchange of Scots pine (Pinus sylvestris L.) shoots. Both measuring and modelling approaches were used in the study. The measurements were performed under noncontrolled field conditions at low ambient NOy concentrations. The chamber blank i.e. artefact NOy emissions from the chamber walls, was dependent on the UV irradiance and increased with time after renewing the Teflon film on chamber surfaces. The contribution of each pine shoot to the total NOy emissions in the chambers was determined by testing whether the emissions decrease when the shoots are removed from their chambers. Emissions did decrease, but only when the chamber interior was exposed to UV radiation. It was concluded that also the pine shoots emit NOy. The possible effects of transpiration on the chamber blank are discussed in the summary part of the thesis, based on previously unpublished data. The possible processes underlying the UV-induced NOy emissions were reviewed. Surface reactions were more likely than metabolic processes. Photolysis of nitrate deposited on the needles may have generated the NOy emissions; the measurements supported this hypothesis. In that case, the emissions apparently would consist mainly of nitrogen dioxide (NO2), nitric oxide (NO) and nitrous acid (HONO). Within studies on NOy exchange of plants, the gases most frequently studied are NO2 and NO (=NOx). In the present work, the implications of the emissions for the NOx exchange of pine were analysed with a model including both NOy emissions and NOy absorption. The model suggested that if the emissions exist, pines can act as an NOx source rather than a sink, even under relatively high ambient concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this thesis was to develop measurement techniques and systems for measuring air quality and to provide information about air quality conditions and the amount of gaseous emissions from semi-insulated and uninsulated dairy buildings in Finland and Estonia. Specialization and intensification in livestock farming, such as in dairy production, is usually accompanied by an increase in concentrated environmental emissions. In addition to high moisture, the presence of dust and corrosive gases, and widely varying gas concentrations in dairy buildings, Finland and Estonia experience winter temperatures reaching below -40 ºC and summer temperatures above +30 ºC. The adaptation of new technologies for long-term air quality monitoring and measurement remains relatively uncommon in dairy buildings because the construction and maintenance of accurate monitoring systems for long-term use are too expensive for the average dairy farmer to afford. Though the documentation of accurate air quality measurement systems intended mainly for research purposes have been made in the past, standardised methods and the documentation of affordable systems and simple methods for performing air quality and emissions measurements in dairy buildings are unavailable. In this study, we built three measurement systems: 1) a Stationary system with integrated affordable sensors for on-site measurements, 2) a Wireless system with affordable sensors for off-site measurements, and 3) a Mobile system consisting of expensive and accurate sensors for measuring air quality. In addition to assessing existing methods, we developed simplified methods for measuring ventilation and emission rates in dairy buildings. The three measurement systems were successfully used to measure air quality in uninsulated, semi-insulated, and fully-insulated dairy buildings between the years 2005 and 2007. When carefully calibrated, the affordable sensors in the systems gave reasonably accurate readings. The spatial air quality survey showed high variation in microclimate conditions in the dairy buildings measured. The average indoor air concentration for carbon dioxide was 950 ppm, for ammonia 5 ppm, for methane 48 ppm, for relative humidity 70%, and for inside air velocity 0.2 m/s. The average winter and summer indoor temperatures during the measurement period were -7º C and +24 ºC for the uninsulated, +3 ºC and +20 ºC for the semi-insulated and +10 ºC and +25 ºC for the fully-insulated dairy buildings. The measurement results showed that the uninsulated dairy buildings had lower indoor gas concentrations and emissions compared to fully insulated buildings. Although occasionally exceeded, the ventilation rates and average indoor air quality in the dairy buildings were largely within recommended limits. We assessed the traditional heat balance, moisture balance, carbon dioxide balance and direct airflow methods for estimating ventilation rates. The direct velocity measurement for the estimation of ventilation rate proved to be impractical for naturally ventilated buildings. Two methods were developed for estimating ventilation rates. The first method is applicable in buildings in which the ventilation can be stopped or completely closed. The second method is useful in naturally ventilated buildings with large openings and high ventilation rates where spatial gas concentrations are heterogeneously distributed. The two traditional methods (carbon dioxide and methane balances), and two newly developed methods (theoretical modelling using Fick s law and boundary layer theory, and the recirculation flux-chamber technique) were used to estimate ammonia emissions from the dairy buildings. Using the traditional carbon dioxide balance method, ammonia emissions per cow from the dairy buildings ranged from 7 g day-1 to 35 g day-1, and methane emissions per cow ranged from 96 g day-1 to 348 g day-1. The developed methods proved to be as equally accurate as the traditional methods. Variation between the mean emissions estimated with the traditional and the developed methods was less than 20%. The developed modelling procedure provided sound framework for examining the impact of production systems on ammonia emissions in dairy buildings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Microbial activity in soils is the main source of nitrous oxide (N2O) to the atmosphere. Nitrous oxide is a strong greenhouse gas in the troposphere and participates in ozone destructive reactions in the stratosphere. The constant increase in the atmospheric concentration, as well as uncertainties in the known sources and sinks of N2O underline the need to better understand the processes and pathways of N2O in terrestrial ecosystems. This study aimed at quantifying N2O emissions from soils in northern Europe and at investigating the processes and pathways of N2O from agricultural and forest ecosystems. Emissions were measured in forest ecosystems, agricultural soils and a landfill, using the soil gradient, chamber and eddy covariance methods. Processes responsible for N2O production, and the pathways of N2O from the soil to the atmosphere, were studied in the laboratory and in the field. These ecosystems were chosen for their potential importance to the national and global budget of N2O. Laboratory experiments with boreal agricultural soils revealed that N2O production increases drastically with soil moisture content, and that the contribution of the nitrification and denitrification processes to N2O emissions depends on soil type. Laboratory study with beech (Fagus sylvatica) seedlings demonstrated that trees can serve as conduits for N2O from the soil to the atmosphere. If this mechanism is important in forest ecosystems, the current emission estimates from forest soils may underestimate the total N2O emissions from forest ecosystems. Further field and laboratory studies are needed to evaluate the importance of this mechanism in forest ecosystems. The emissions of N2O from northern forest ecosystems and a municipal landfill were highly variable in time and space. The emissions of N2O from boreal upland forest soil were among the smallest reported in the world. Despite the low emission rates, the soil gradient method revealed a clear seasonal variation in N2O production. The organic topsoil was responsible for most of the N2O production and consumption in this forest soil. Emissions from the municipal landfill were one to two orders of magnitude higher than those from agricultural soils, which are the most important source of N2O to the atmosphere. Due to their small areal coverage, landfills only contribute minimally to national N2O emissions in Finland. The eddy covariance technique was demonstrated to be useful for measuring ecosystem-scale emissions of N2O in forest and landfill ecosystems. Overall, more measurements and integration between different measurement techniques are needed to capture the large variability in N2O emissions from natural and managed northern ecosystems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Airway inflammation is a key feature of bronchial asthma. In asthma management, according to international guidelines, the gold standard is anti-inflammatory treatment. Currently, only conventional procedures (i.e., symptoms, use of rescue medication, PEF-variability, and lung function tests) were used to both diagnose and evaluate the results of treatment with anti-inflammatory drugs. New methods for evaluation of degree of airway inflammation are required. Nitric oxide (NO) is a gas which is produced in the airways of healthy subjects and especially produced in asthmatic airways. Measurement of NO from the airways is possible, and NO can be measured from exhaled air. Fractional exhaled NO (FENO) is increased in asthma, and the highest concentrations are measured in asthmatic patients not treated with inhaled corticosteroids (ICS). Steroid-treated patients with asthma had levels of FENO similar to those of healthy controls. Atopic asthmatics had higher levels of FENO than did nonatopic asthmatics, indicating that level of atopy affected FENO level. Associations between FENO and bronchial hyperresponsiveness (BHR) occur in asthma. The present study demonstrated that measurement of FENO had good reproducibility, and the FENO variability was reasonable both short- and long-term in both healthy subjects and patients with respiratory symptoms or asthma. We demonstrated the upper normal limit for healthy subjects, which was 12 ppb calculated from two different healthy study populations. We showed that patients with respiratory symptoms who did not fulfil the diagnostic criteria of asthma had FENO values significantly higher than in healthy subjects, but significantly lower than in asthma patients. These findings suggest that BHR to histamine is a sensitive indicator of the effect of ICS and a valuable tool for adjustment of corticosteroid treatment in mild asthma. The findings further suggest that intermittent treatment periods of a few weeks’ duration are insufficient to provide long-term control of BHR in patients with mild persistent asthma. Moreover, during the treatment with ICS changes in BHR and changes in FENO were associated. FENO level was associated with BHR measured by a direct (histamine challenge) or indirect method (exercise challenge) in steroid-naïve symptomatic, non-smoking asthmatics. Although these associations could be found only in atopics, FENO level in nonatopic asthma was also increased. It can thus be concluded that assessment of airway inflammation by measuring FENO can be useful for clinical purposes. The methodology of FENO measurements is now validated. Especially in those patients with respiratory symptoms who did not fulfil the diagnostic criteria of asthma, FENO measurement can aid in treatment decisions. Serial measurement of FENO during treatment with ICS can be a complementary or an alternative method for evaluation in patients with asthma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most women acquire genital high risk human papillomavirus (HPV) infection during their lifetime, but seldom the infection persists and leads to cervical cancer. However, currently it is not possible to identify the women who will develop HPV mediated cervical cancer and this often results to large scale follow-up and overtreatment of the likely spontaneously regressing infection. Thus, it is important to obtain more information on the course of HPV and find markers that could help to identify HPV infected women in risk for progression of cervical lesions and ultimately cancer. Nitric oxide is a free radical gas that takes part both in immune responses and carcinogenesis. Nitric oxide is produced also by cervical cells and therefore, it is possible that cervical nitric oxide could affect also HPV infection. In the present study, including 801 women from the University of Helsinki between years of 2006 and 2011, association between HPV and cervical nitric oxide was evaluated. The levels of nitric oxide were measured as its metabolites nitrate and nitirite (NOx) by spectrophotometry and the expression of nitric oxide producing enzymes endothelial and inducible synthases (eNOS, iNOS) by Western blotting. Women infected with HPV had two-times higher cervical fluid NOx levels compared with non-infected ones. The expression levels of both eNOS and iNOS were higher in HPV-infected women compared with non-infected. Another sexually transmitted disease Chlamydia trachomatis that is an independent risk factor for cervical cancer was also accompanied with elevated NOx levels, whereas vaginal infections, bacterial vaginosis and candida, did not have any effect on NOx levels. The meaning of the elevated HPV related cervical nitric oxide was evaluated in a 12 months follow-up study. It was revealed that high baseline cervical fluid NOx levels favored HPV persistence with OR 4.1. However, low sensitivity (33%) and high false negative rate (67%) restrict the clinical use of the current NOx test. This study indicated that nitric oxide favors HPV persistence and thus it seems to be one of the cofactor associated with a risk of carcinogenesis.