27 resultados para Medical simulation
em Helda - Digital Repository of University of Helsinki
Resumo:
Noise can be defined as unwanted sound. It may adversely affect the health and well-being of individuals. Noise sensitivity is a personality trait covering attitudes towards noise in general and a predictor of noise annoyance. Noise sensitive individuals are more affected by noise than less sensitive individuals. The determinants and characteristics related to noise sensitivity are rather poorly known. The risk of health effects caused by noise can be hypothesized to be higher for noise sensitive individuals compared to those who are not noise sensitive. A cardiovascular disease may be an example of outcomes. The general aim of the present study was to investigate the association of noise sensitivity with specific somatic and psychological factors, including the genetic component of noise sensitivity, and the association of noise sensitivity with mortality. The study was based on the Finnish Twin Cohort of same-sex twin pairs born before 1958. In 1988 a questionnaire was sent to twin pairs discordant for hypertension. 1495 individuals (688 men, 807 women) aged 31 88 years replied, including 573 twin pairs. 218 of the subjects lived in the Helsinki Metropolitan Area. Self-reported noise sensitivity, lifetime noise exposure and hypertension were obtained from the questionnaire study in 1988 and other somatic and psychological factors from the questionnaire study in 1981 for the same individuals. In addition, noise map information (1988 1992) from the Helsinki Metropolitan Area and mortality follow-up 1989 2003 were used. To evaluate the stability and validity of noise sensitivity, a new questionnaire was sent in 2002 to a sample of the subjects who had replied to the 1988 questionnaire. Of all subjects who had answered the question on noise sensitivity, 38 % were noise sensitive. Noise sensitivity was independent of noise exposure levels indicated in noise maps. Subjects with high noise sensitivity reported more transportation noise exposure than subjects with low noise sensitivity. Noise sensitive subjects reported transportation noise exposure outside the environmental noise map areas almost twice as often as non-sensitive subjects. Noise sensitivity was associated with hypertension, emphysema, use of psychotropic drugs, smoking, stress and hostility, even when lifetime noise exposure was adjusted for. Monozygotic twin pairs were more similar with regards noise sensitivity than dizygotic twin pairs, and quantitative genetic modelling indicated significant familiality. The best fitting genetic model provided an estimate of heritability of 36 %. Follow-up of subjects in the case-control study showed that cardiovascular mortality was significantly increased among noise sensitive women, but not among men. For coronary heart mortality the interaction of noise sensitivity and lifetime noise exposure was statistically significant in women. In conclusion, noise sensitivity has both somatic and psychological components. It does aggregate in families and probably has a genetic component. Noise sensitivity may be a risk factor for cardiovascular mortality in women.
Resumo:
Forest management is facing new challenges under climate change. By adjusting thinning regimes, conventional forest management can be adapted to various objectives of utilization of forest resources, such as wood quality, forest bioenergy, and carbon sequestration. This thesis aims to develop and apply a simulation-optimization system as a tool for an interdisciplinary understanding of the interactions between wood science, forest ecology, and forest economics. In this thesis, the OptiFor software was developed for forest resources management. The OptiFor simulation-optimization system integrated the process-based growth model PipeQual, wood quality models, biomass production and carbon emission models, as well as energy wood and commercial logging models into a single optimization model. Osyczka s direct and random search algorithm was employed to identify optimal values for a set of decision variables. The numerical studies in this thesis broadened our current knowledge and understanding of the relationships between wood science, forest ecology, and forest economics. The results for timber production show that optimal thinning regimes depend on site quality and initial stand characteristics. Taking wood properties into account, our results show that increasing the intensity of thinning resulted in lower wood density and shorter fibers. The addition of nutrients accelerated volume growth, but lowered wood quality for Norway spruce. Integrating energy wood harvesting into conventional forest management showed that conventional forest management without energy wood harvesting was still superior in sparse stands of Scots pine. Energy wood from pre-commercial thinning turned out to be optimal for dense stands. When carbon balance is taken into account, our results show that changing carbon assessment methods leads to very different optimal thinning regimes and average carbon stocks. Raising the carbon price resulted in longer rotations and a higher mean annual increment, as well as a significantly higher average carbon stock over the rotation.
Resumo:
Boron neutron capture therapy (BNCT) is a form of chemically targeted radiotherapy that utilises the high neutron capture cross-section of boron-10 isotope to achieve a preferential dose increase in the tumour. The BNCT dosimetry poses a special challenge as the radiation dose absorbed by the irradiated tissues consists of several dose different components. Dosimetry is important as the effect of the radiation on the tissue is correlated with the radiation dose. Consistent and reliable radiation dose delivery and dosimetry are thus basic requirements for radiotherapy. The international recommendations for are not directly applicable to BNCT dosimetry. The existing dosimetry guidance for BNCT provides recommendations but also calls for investigating for complementary methods for comparison and improved accuracy. In this thesis the quality assurance and stability measurements of the neutron beam monitors used in dose delivery are presented. The beam monitors were found not to be affected by the presence of a phantom in the beam and that the effect of the reactor core power distribution was less than 1%. The weekly stability test with activation detectors has been generally reproducible within the recommended tolerance value of 2%. An established toolkit for epithermal neutron beams for determination of the dose components is presented and applied in an international dosimetric intercomparison. The measured quantities (neutron flux, fast neutron and photon dose) by the groups in the intercomparison were generally in agreement within the stated uncertainties. However, the uncertainties were large, ranging from 3-30% (1 standard deviation), emphasising the importance of dosimetric intercomparisons if clinical data is to be compared between different centers. Measurements with the Exradin type 2M ionisation chamber have been repeated in the epithermal neutron beam in the same measurement configuration over the course of 10 years. The presented results exclude severe sensitivity changes to thermal neutrons that have been reported for this type of chamber. Microdosimetry and polymer gel dosimetry as complementary methods for epithermal neutron beam dosimetry are studied. For microdosimetry the comparison of results with ionisation chambers and computer simulation showed that the photon dose measured with microdosimetry was lower than with the two other methods. The disagreement was within the uncertainties. For neutron dose the simulation and microdosimetry results agreed within 10% while the ionisation chamber technique gave 10-30% lower neutron dose rates than the two other methods. The response of the BANG-3 gel was found to be linear for both photon and epithermal neutron beam irradiation. The dose distribution normalised to dose maximum measured by MAGIC polymer gel was found to agree well with the simulated result near the dose maximum while the spatial difference between measured and simulated 30% isodose line was more than 1 cm. In both the BANG-3 and MAGIC gel studies, the interpretation of the results was complicated by the presence of high-LET radiation.