10 resultados para Magneto-optical imaging techniques

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The surface properties of solid state pharmaceutics are of critical importance. Processing modifies the surfaces and effects surface roughness, which influences the performance of the final dosage form in many different levels. Surface roughness has an effect on, e.g., the properties of powders, tablet compression and tablet coating. The overall goal of this research was to understand the surface structures of pharmaceutical surfaces. In this context the specific purpose was to compare four different analysing techniques (optical microscopy, scanning electron microscopy, laser profilometry and atomic force microscopy) in various pharmaceutical applications where the surfaces have quite different roughness scale. This was done by comparing the image and roughness analysing techniques using powder compacts, coated tablets and crystal surfaces as model surfaces. It was found that optical microscopy was still a very efficient technique, as it yielded information that SEM and AFM imaging are not able to provide. Roughness measurements complemented the image data and gave quantitative information about height differences. AFM roughness data represents the roughness of only a small part of the surface and therefore needs other methods like laser profilometer are needed to provide a larger scale description of the surface. The new developed roughness analysing method visualised surface roughness by giving detailed roughness maps, which showed local variations in surface roughness values. The method was able to provide a picture of the surface heterogeneity and the scale of the roughness. In the coating study, the laser profilometer results showed that the increase in surface roughness was largest during the first 30 minutes of coating when the surface was not yet fully covered with coating. The SEM images and the dispersive X-ray analysis results showed that the surface was fully covered with coating within 15 to 30 minutes. The combination of the different measurement techniques made it possible to follow the change of surface roughness and development of polymer coating. The optical imaging techniques gave a good overview of processes affecting the whole crystal surface, but they lacked the resolution to see small nanometer scale processes. AFM was used to visualize the nanoscale effects of cleaving and reveal the full surface heterogeneity, which underlies the optical imaging. Ethanol washing changed small (nanoscale) structure to some extent, but the effect of ethanol washing on the larger scale was small. Water washing caused total reformation of the surface structure at all levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rupture of a cerebral artery aneurysm causes a devastating subarachnoid hemorrhage (SAH), with a mortality of almost 50% during the first month. Each year, 8-11/100 000 people suffer from aneurysmal SAH in Western countries, but the number is twice as high in Finland and Japan. The disease is most common among those of working age, the mean age at rupture being 50-55 years. Unruptured cerebral aneurysms are found in 2-6% of the population, but knowledge about the true risk of rupture is limited. The vast majority of aneurysms should be considered rupture-prone, and treatment for these patients is warranted. Both unruptured and ruptured aneurysms can be treated by either microsurgical clipping or endovascular embolization. In a standard microsurgical procedure, the neck of the aneurysm is closed by a metal clip, sealing off the aneurysm from the circulation. Endovascular embolization is performed by packing the aneurysm from the inside of the vessel lumen with detachable platinum coils. Coiling is associated with slightly lower morbidity and mortality than microsurgery, but the long-term results of microsurgically treated aneurysms are better. Endovascular treatment methods are constantly being developed further in order to achieve better long-term results. New coils and novel embolic agents need to be tested in a variety of animal models before they can be used in humans. In this study, we developed an experimental rat aneurysm model and showed its suitability for testing endovascular devices. We optimized noninvasive MRI sequences at 4.7 Tesla for follow-up of coiled experimental aneurysms and for volumetric measurement of aneurysm neck remnants. We used this model to compare platinum coils with polyglycolic-polylactic acid (PGLA) -coated coils, and showed the benefits of the latter in this model. The experimental aneurysm model and the imaging methods also gave insight into the mechanisms involved in aneurysm formation, and the model can be used in the development of novel imaging techniques. This model is affordable, easily reproducible, reliable, and suitable for MRI follow-up. It is also suitable for endovascular treatment, and it evades spontaneous occlusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eturauhassyöpä on yksi yleisimmistä syövistä länsimaissa. Eturauhassyöpä on yleensä hitaasti kehittyvä tauti. Edetessään se voi kuitenkin muuntua aggressiivisemmaksi ja aiheuttaa metastaaseja, jotka ovat pääasiallisena syynä taudin kuolleisuuteen. Androgeenit ovat merkittäviä tekijöitä eturauhassyövän patogeneesissä ja eturauhassyöpäkudos on useimmiten riippuvainen androgeeneista. Tämän vuoksi hoidon tavoitteena on estää niiden eritys kirurgisella tai kemiallisella kastraatiolla ja/tai estää androgeenien vaikutus antiandrogeeneilla. Eturauhassyöpää sekä sen hoitoon tarkoitettuja uusia lääkehoitomahdollisuuksia tutkitaan kiivaasti. Eturauhassyövän tutkimiseen on kehitetty lukematon määrä erilaisia in vivo -malleja. Koska eturauhassyöpä on yleensä androgeeneille herkkä, kuvaavat androgeeniresponsiiviset eläinmallit ihmisen tautia parhaiten. Eturauhassyövän mallintamiseen in vivo voidaan käyttää eri eläinlajeja, mutta hiiri on ylivoimaisesti käytetyin mallieläin. Immuunipuutteisiin hiiriin voidaan aiheuttaa kasvaimia inokuloimalla ihmisen kasvainsoluja tai osia ihmisen kasvaimista. Ortotooppisesti eturauhaseen inokuloitavat kasvainmallit mallintavat eturauhassyövässä esiintyvää syöpäsolujen ja stroomasolujen välistä epänormaalia vuorovaikutusta. Muuntogeeniset hiirimallit ovat yhä yleisempiä eturauhassyövän tutkimuksessa. Muuntogeenisilla malleilla voidaan mallintaa taudin kehittymistä ja sen etenemistä kokonaisuudessaan parhaiten. Eturauhasessa olevaa kasvainta ja sen kasvua on vaikea seurata ilman prostataspesifisen antigeenin (PSA) pitoisuuden mittausta tai erityisiä kuvantamistekniikoita. Tällaisia menetelmiä, kuten optista kuvantamista, käytetään yhä enemmän hyödyksi erilaisissa eturauhassyövän in vivo -malleissa. Tutkielman kokeellisen osan tavoitteena oli optimoida bioluminesenssiin perustuva optinen kuvantamismenetelmä androgeeniresponsiivisessa LNCaP-luc2-solulinjassa ortotooppisessa eturauhassyöpämallissa. Bioluminesenssikuvantaminen perustuu kasvainsolujen ilmentämän lusiferaasin katalysoimaan reaktioon, jossa entsyymin substraatti, lusiferiini, hapettuu ja tuottaa näkyvää valoa. Lisäksi tavoitteena oli tutkia lääkehoitojen ja kastraation vasteita mallissa. Bioluminesenssiin perustuvalla kuvantamisella oli mahdollista seurata eturauhaskasvainten kasvua noninvasiivisesti, reaaliaikaisesti ja toistuvasti. Bioluminesenssikuvantamisen avulla kasvainten kvantitointi oli nopeampaa kuin ultraäänikuvantamisen avulla, ja kasvainten kasvua oli myös mahdollista seurata useammin kuin seerumin PSA-mittausten avulla. Bioluminesenssikuvantamisen todettiin korreloivan paremmin PSA-pitoisuuden kanssa kuin kasvaimen todelliseen kokoon lopetushetkellä. Seerumin PSA-pitoisuus korreloi kuitenkin bioluminesenssimittausta paremmin eturauhaskasvaimen kokoon tässä kokeessa. Kasvainten oletettua suurempaa kokoa voidaan pitää todennäköisimpänä syynä sille, ettei lääkehoitojen tai kastraation todettu vaikuttavan kasvainten kasvuun bioluminesenssikuvantamisella mitattuna. Bioluminesenssikuvantaminen ei sovellu suurille eikä nekroottisille kasvaimille, sillä kuvantamismenetelmä toimii vain elävillä soluilla. Bioluminesenssikuvantamisen hyödyntämisen kannalta oleellista tässä mallissa on myös lusiferiini-injektion onnistuminen. Jatkotutkimuksia tarvitaan edelleen mallin validoimiseksi mm. lääkehoitojen vasteiden osoittamiseksi.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In dentistry, basic imaging techniques such as intraoral and panoramic radiography are in most cases the only imaging techniques required for the detection of pathology. Conventional intraoral radiographs provide images with sufficient information for most dental radiographic needs. Panoramic radiography produces a single image of both jaws, giving an excellent overview of oral hard tissues. Regardless of the technique, plain radiography has only a limited capability in the evaluation of three-dimensional (3D) relationships. Technological advances in radiological imaging have moved from two-dimensional (2D) projection radiography towards digital, 3D and interactive imaging applications. This has been achieved first by the use of conventional computed tomography (CT) and more recently by cone beam CT (CBCT). CBCT is a radiographic imaging method that allows accurate 3D imaging of hard tissues. CBCT has been used for dental and maxillofacial imaging for more than ten years and its availability and use are increasing continuously. However, at present, only best practice guidelines are available for its use, and the need for evidence-based guidelines on the use of CBCT in dentistry is widely recognized. We evaluated (i) retrospectively the use of CBCT in a dental practice, (ii) the accuracy and reproducibility of pre-implant linear measurements in CBCT and multislice CT (MSCT) in a cadaver study, (iii) prospectively the clinical reliability of CBCT as a preoperative imaging method for complicated impacted lower third molars, and (iv) the tissue and effective radiation doses and image quality of dental CBCT scanners in comparison with MSCT scanners in a phantom study. Using CBCT, subjective identification of anatomy and pathology relevant in dental practice can be readily achieved, but dental restorations may cause disturbing artefacts. CBCT examination offered additional radiographic information when compared with intraoral and panoramic radiographs. In terms of the accuracy and reliability of linear measurements in the posterior mandible, CBCT is comparable to MSCT. CBCT is a reliable means of determining the location of the inferior alveolar canal and its relationship to the roots of the lower third molar. CBCT scanners provided adequate image quality for dental and maxillofacial imaging while delivering considerably smaller effective doses to the patient than MSCT. The observed variations in patient dose and image quality emphasize the importance of optimizing the imaging parameters in both CBCT and MSCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tactile sensation plays an important role in everyday life. While the somatosensory system has been studied extensively, the majority of information has come from studies using animal models. Recent development of high-resolution anatomical and functional imaging techniques has enabled the non-invasive study of human somatosensory cortex and thalamus. This thesis provides new insights into the functional organization of the human brain areas involved in tactile processing using magnetoencephalography (MEG) and functional magnetic resonance imaging (fMRI). The thesis also demonstrates certain optimizations of MEG and fMRI methods. Tactile digit stimulation elicited stimulus-specific responses in a number of brain areas. Contralateral activation was observed in somatosensory thalamus (Study II), primary somatosensory cortex (SI; I, III, IV), and post-auditory belt area (III). Bilateral activation was observed in secondary somatosensory cortex (SII; II, III, IV). Ipsilateral activation was found in the post-central gyrus (area 2 of SI cortex; IV). In addition, phasic deactivation was observed within ipsilateral SI cortex and bilateral primary motor cortex (IV). Detailed investigation of the tactile responses demonstrated that the arrangement of distal-proximal finger representations in area 3b of SI in humans is similar to that found in monkeys (I). An optimized MEG approach was sufficient to resolve such fine detail in functional organization. The SII region appeared to contain double representations for fingers and toes (II). The detection of activations in the SII region and thalamus improved at the individual and group levels when cardiac-gated fMRI was used (II). Better detection of body part representations at the individual level is an important improvement, because identification of individual representations is crucial for studying brain plasticity in somatosensory areas. The posterior auditory belt area demonstrated responses to both auditory and tactile stimuli (III), implicating this area as a physiological substrate for the auditory-tactile interaction observed in earlier psychophysical studies. Comparison of different smoothing parameters (III) demonstrated that proper evaluation of co-activation should be based on individual subject analysis with minimal or no smoothing. Tactile input consistently influenced area 3b of the human ipsilateral SI cortex (IV). The observed phasic negative fMRI response is proposed to result from interhemispheric inhibition via trans-callosal connections. This thesis contributes to a growing body of human data suggesting that processing of tactile stimuli involves multiple brain areas, with different spatial patterns of cortical activation for different stimuli.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diagnostic radiology represents the largest man-made contribution to population radiation doses in Europe. To be able to keep the diagnostic benefit versus radiation risk ratio as high as possible, it is important to understand the quantitative relationship between the patient radiation dose and the various factors which affect the dose, such as the scan parameters, scan mode, and patient size. Paediatric patients have a higher probability for late radiation effects, since longer life expectancy is combined with the higher radiation sensitivity of the developing organs. The experience with particular paediatric examinations may be very limited and paediatric acquisition protocols may not be optimised. The purpose of this thesis was to enhance and compare different dosimetric protocols, to promote the establishment of the paediatric diagnostic reference levels (DRLs), and to provide new data on patient doses for optimisation purposes in computed tomography (with new applications for dental imaging) and in paediatric radiography. Large variations in radiation exposure in paediatric skull, sinus, chest, pelvic and abdominal radiography examinations were discovered in patient dose surveys. There were variations between different hospitals and examination rooms, between different sized patients, and between imaging techniques; emphasising the need for harmonisation of the examination protocols. For computed tomography, a correction coefficient, which takes individual patient size into account in patient dosimetry, was created. The presented patient size correction method can be used for both adult and paediatric purposes. Dental cone beam CT scanners provided adequate image quality for dentomaxillofacial examinations while delivering considerably smaller effective doses to patient compared to the multi slice CT. However, large dose differences between cone beam CT scanners were not explained by differences in image quality, which indicated the lack of optimisation. For paediatric radiography, a graphical method was created for setting the diagnostic reference levels in chest examinations, and the DRLs were given as a function of patient projection thickness. Paediatric DRLs were also given for sinus radiography. The detailed information about the patient data, exposure parameters and procedures provided tools for reducing the patient doses in paediatric radiography. The mean tissue doses presented for paediatric radiography enabled future risk assessments to be done. The calculated effective doses can be used for comparing different diagnostic procedures, as well as for comparing the use of similar technologies and procedures in different hospitals and countries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Syövän diagnostiikassa ja hoidossa nanopartikkelit voivat toimia kuljetinaineina lääke- ja diagnostisille aineille tai nukleiinihappojaksoille. Kantaja-aineeseen voidaan liittää kohdennusmolekyylejä partikkelien passiivista tai aktiivista kohdennusta varten tai radioleima kuvantamista tai radioterapiaa varten. Kantaja-aineiden avulla voidaan parantaa lääkeaineen fysikaalis-kemiallisia ominaisuuksia ja biologista hyötyosuutta, vähentää systeemisiä sivuvaikutuksia, pidentää lääkeaineen puoliintumisaikaa ja siten harventaa annosteluväliä, sekä parantaa lääkeaineen pääsyä kohdekudokseen. Näin voidaan parantaa kemo- ja radioterapian tehoa ja hoidon onnistumisen todennäköisyyttä. Kirjallisuuskatsauksessa perehdytään nanokantajien rooliin syövän hoidossa. Vuosikymmeniä jatkuneesta tutkimuksesta huolimatta vain kaksi (Eurooppa) tai kolme (Yhdysvallat) nanopartikkeliformulaatiota on hyväksytty markkinoille syövän hoidossa. Ongelmina ovat riittämätön hakeutuminen kohdekudokseen, immunogeenisyys ja nanopartikkelien labiilius. Kokeellisessa osassa tutkitaan in vitro ja hiirillä in vivo 99mTc-leimattujen, PEG-verhoiltujen biotiiniliposomien kaksivaiheista kohdennusta ihmisen munasarjan adenokarsinoomasoluihin. Kohdentamiseen käytetään biotinyloitua setuksimabi-(Erbitux®) vasta-ainetta, joka sitoutuu solujen yli-ilmentämiin EGF-reseptoreihin. Kaksivaiheista kohdennusta verrataan suoraan ja/tai passiiviseen kohdennukseen. Tehokkaampien kuvantamismenetelmien kehitys on vauhdittanut kohdennettujen nanopartikkelien tutkimusta. Isotooppikuvantamista käyttäen pystytään seuraamaan radioleiman jakautumista elimistössä ja kuvantamaan solutasolla tapahtuvia ilmiöitä. Kirjallisuuskatsauksessa perehdytään SPECT- ja PET-kuvantamiseen syövän hoidossa, sekä niiden hyödyntämiseen lääkekehityksessä nanopartikkelien kuvantamisessa. Kyseiset kuvantamismenetelmät erottuvat muista menetelmistä korkean erotuskyvyn, herkkyyden ja helppokäyttöisyyden suhteen. Kokeellisessa osassa 99mTc-leimattujen liposomien distribuutiota hiirissä tutkittiin SPECT-CT-laitteen avulla. Aktiivisuus kasvaimessa, pernassa ja maksassa kvantifioitiin InVivoScope-ohjelman ja gammalaskijan avulla. Tuloksia verrattiin keskenään. In vitro-kokeessa saavutettiin kaksivaiheisella kohdennuksella 2,7- 3,5-kertainen (solulinjasta riippuen) hakeutuminen soluihin kontrolliliposomeihin verrattuna. Kuitenkin suora kohdennus toimi kaksivaiheista kohdennusta paremmin in vitro. In vivo –kokeissa liposomit jakautuivat kasvaimeen tehokkaammin i.p.-annosteltuna kuin i.v.-annosteltuna. Kaksivaiheisella kohdennuksella saavutettiin 1,24-kertainen jakautuminen kasvaimeen (% ID/g kudosta) passiivisesti kohdennettuihin liposomeihin verrattuna. %ID/elin oli kohdennetuilla liposomeilla 5,9 % ja passiivisesti kohdennetuilla 5,4%. Todellinen ero oli siis pieni. InVivoScope:n ja gammalaskijan tulokset eivät korreloineet keskenään. Lisätutkimuksia ja menetelmän optimointia vaaditaan liposomien kohdennuksessa kasvaimeen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The equilibrium between cell proliferation, differentiation, and apoptosis is crucial for maintaining homeostasis in epithelial tissues. In order for the epithelium to function properly, individual cells must gain normal structural and functional polarity. The junctional proteins have an important role both in binding the cells together and in taking part in cell signaling. Cadherins form adherens junctions. Cadherins initiate the polarization process by first recognizing and binding the neighboring cells together, and then guiding the formation of tight junctions. Tight junctions form a barrier in dividing the plasma membranes to apical and basolateral membrane domains. In glandular tissues, single layered and polarized epithelium is folded into tubes or spheres, in which the basal side of the epithelial layer faces the outer basal membrane, and the apical side the lumen. In carcinogenesis, the differentiated architecture of an epithelial layer is disrupted. Filling of the luminal space is a hallmark of early epithelial tumors in tubular and glandular structures. In order for the transformed tumor cells to populate the lumen, enhanced proliferation as well as inhibition of apoptosis is required. Most advances in cancer biology have been achieved by using two-dimensional (2D) cell culture models, in which the cells are cultured on flat surfaces as monolayers. However, the 2D cultures are limited in their capacity to recapitulate the structural and functional features of tubular structures and to represent cell growth and differentiation in vivo. The development of three-dimensional (3D) cell culture methods enables the cells to grow and to be studied in a more natural environment. Despite the wide use of 2D cell culture models and the development of novel 3D culture methods, it is not clear how the change of the dimensionality of culture conditions alters the polarization and transformation process and the molecular mechanisms behind them. Src is a well-known oncogene. It is found in focal and adherens junctions of cultured cells. Active src disrupts cell-cell junctions and interferes with cell-matrix binding. It promotes cell motility and survival. Src transformation in 2D disrupts adherens junctions and the fibroblastic phenotype of the cells. In 3D, the adherens junctions are weakened, and in glandular structures, the lumen is filled with nonpolarized vital cells. Madin-Darby canine kidney (MDCK) cells are an epithelial cell type commonly used as a model for cell polarization. Its-src-transformed variants are useful model systems for analyzing the changes in cell morphology, and they play a role in src-induced malignant transformation. This study investigates src-transformed cells in 3D cell cultures as a model for malignant transformation. The following questions were posed. Firstly: What is the role of the composition and stiffness of the extracellular matrix (ECM) on the polarization and transformation of ts v-src MDCK cells in 3D cell cultures? Secondly: How do the culture conditions affect gene expression? What is the effect of v-src transformation in 2D and in 3D cell models? How does the shift from 2D to 3D affect cell polarity and gene expression? Thirdly: What is the role of survivin and its regulator phosphatase and tensin homolog protein (PTEN) in cell polarization and transformation, and in determining cell fate? How does their expression correlate with impaired mitochondrial function in transformed cells? In order to answer the above questions, novel methods of culturing and monitoring cells had to be created: novel 3D methods of culturing epithelial cells were engineered, enabling real time monitoring of a polarization and transformation process, and functional testing of 3D cell cultures. Novel 3D cell culture models and imaging techniques were created for the study. Attention was focused especially on confocal microscopy and live-cell imaging. Src-transformation disturbed the polarization of the epithelium by disrupting cell adhesion, and sensitized the cells to their environment. With active src, the morphology of the cell cluster depended on the composition and stiffness of the matrix. Gene expression studies revealed a broader impact of src transformation than mere continuous activity of src-kinase. In 2D cultures, src transformation altered the expression of immunological, actin cytoskeleton and extracellular matrix (ECM). In 3D, the genes regulating cell division, inhibition of apoptosis, cell metabolism, mitochondrial function, actin cytoskeleton and mechano-sensing proteins were altered. Surprisingly, changing the culture conditions from 2D to 3D affected also gene expression considerably. The microarray hit survivin, an inhibitor of apoptosis, played a crucial role in the survival and proliferation of src-transformed cells.