5 resultados para Letter-pictures.
em Helda - Digital Repository of University of Helsinki
Resumo:
Anselm of Canterbury (1033–1109) was a prolific letter writer. The modern edition of his letter collection comprises more than 600 folio-size pages in print and includes 472 letters, the vast majority of which were sent by him. Our knowledge of Anselm’s letters is derived from collections of his letters, for none of his correspondence survives in its original form of individual letters. There was no one canonical version of the collection, and the extant manuscripts generally differ substantially: the largest medieval manuscript witnesses include over 400 letters, while the smallest contain only a few. We know 38 manuscript witnesses, but no authorial manuscript survives. Certain references in Anselm’s letters reveal, however, that he collected his correspondence on at least two occasions while he was still abbot of Bec, and this study proposes that a third collection was possibly made under his supervision in Christ Church. The third collection also covered Anselm’s Canterbury period. Whether the third collection was authorial or posthumous is unclear. Certain contextual evidence and references in letters would suggest that the collection was authorial. If so, the collection was probably a register book, which was started in c. 1101 at the earliest. There is no positive proof that any of the three surviving minor collections may be authorial. Each of these collections was circulating at a very early stage, however, some probably in Anselm’s lifetime. Moreover, the minor collections seem to have been put together from smaller source units, which possibly originated at Bec. The contents of these units suggest very early and possibly authorial origins: the letters are mainly from Anselm’s years as prior of Bec. The critical edition by F. S. Schmitt represents the current phase in the textual tradition of Anselm’s letter collection. This study demonstrates that the value of the edition is weakened in particular by the way in which Schmitt selected manuscripts for collation, doubtless influenced by the fact that he had not established the structure of the tradition properly. Ultimately it is impossible to undertake systematic research on the letter collection on the basis of Schmitt’s edition.
Resumo:
It has been suggested that semantic information processing is modularized according to the input form (e.g., visual, verbal, non-verbal sound). A great deal of research has concentrated on detecting a separate verbal module. Also, it has traditionally been assumed in linguistics that the meaning of a single clause is computed before integration to a wider context. Recent research has called these views into question. The present study explored whether it is reasonable to assume separate verbal and nonverbal semantic systems in the light of the evidence from event-related potentials (ERPs). The study also provided information on whether the context influences processing of a single clause before the local meaning is computed. The focus was on an ERP called N400. Its amplitude is assumed to reflect the effort required to integrate an item to the preceding context. For instance, if a word is anomalous in its context, it will elicit a larger N400. N400 has been observed in experiments using both verbal and nonverbal stimuli. Contents of a single sentence were not hypothesized to influence the N400 amplitude. Only the combined contents of the sentence and the picture were hypothesized to influence the N400. The subjects (n = 17) viewed pictures on a computer screen while hearing sentences through headphones. Their task was to judge the congruency of the picture and the sentence. There were four conditions: 1) the picture and the sentence were congruent and sensible, 2) the sentence and the picture were congruent, but the sentence ended anomalously, 3) the picture and the sentence were incongruent but sensible, 4) the picture and the sentence were incongruent and anomalous. Stimuli from the four conditions were presented in a semi-randomized sequence. Their electroencephalography was simultaneously recorded. ERPs were computed for the four conditions. The amplitude of the N400 effect was largest in the incongruent sentence-picture -pairs. The anomalously ending sentences did not elicit a larger N400 than the sensible sentences. The results suggest that there is no separate verbal semantic system, and that the meaning of a single clause is not processed independent of the context.
Resumo:
Letter of intent describing SiD (Silicon Detector) for consideration by the International Linear Collider IDAG panel. This detector concept is founded on the use of silicon detectors for vertexing, tracking, and electromagnetic calorimetry. The detector has been cost-optimized as a general-purpose detector for a 500 GeV electron-positron linear collider.
Resumo:
Letter of intent describing SiD (Silicon Detector) for consideration by the International Linear Collider IDAG panel. This detector concept is founded on the use of silicon detectors for vertexing, tracking, and electromagnetic calorimetry. The detector has been cost-optimized as a general-purpose detector for a 500 GeV electron-positron linear collider.
Resumo:
The International Large Detector (ILD) is a concept for a detector at the International Linear Collider, ILC. The ILC will collide electrons and positrons at energies of initially 500 GeV, upgradeable to 1 TeV. The ILC has an ambitious physics program, which will extend and complement that of the Large Hadron Collider (LHC). A hallmark of physics at the ILC is precision. The clean initial state and the comparatively benign environment of a lepton collider are ideally suited to high precision measurements. To take full advantage of the physics potential of ILC places great demands on the detector performance. The design of ILD is driven by these requirements. Excellent calorimetry and tracking are combined to obtain the best possible overall event reconstruction, including the capability to reconstruct individual particles within jets for particle ow calorimetry. This requires excellent spatial resolution for all detector systems. A highly granular calorimeter system is combined with a central tracker which stresses redundancy and efficiency. In addition, efficient reconstruction of secondary vertices and excellent momentum resolution for charged particles are essential for an ILC detector. The interaction region of the ILC is designed to host two detectors, which can be moved into the beam position with a push-pull scheme. The mechanical design of ILD and the overall integration of subdetectors takes these operational conditions into account.