7 resultados para Infrared equipment

em Helda - Digital Repository of University of Helsinki


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical or contaminated ethanol products are sometimes ingested either accidentally or on purpose. Typical misused products are black-market liquor and automotive products, e.g., windshield washer fluids. In addition to less toxic solvents, these liquids may contain the deadly methanol. Symptoms of even lethal solvent poisoning are often non-specific at the early stage. The present series of studies was carried out to develop a method for solvent intoxication breath diagnostics to speed up the diagnosis procedure conventionally based on blood tests. Especially in the case of methanol ingestion, the analysis method should be sufficiently sensitive and accurate to determine the presence of even small amounts of methanol from the mixture of ethanol and other less-toxic components. In addition to the studies on the FT-IR method, the Dräger 7110 evidential breath analyzer was examined to determine its ability to reveal a coexisting toxic solvent. An industrial Fourier transform infrared analyzer was modified for breath testing. The sample cell fittings were widened and the cell size reduced in order to get an alveolar sample directly from a single exhalation. The performance and the feasibility of the Gasmet FT-IR analyzer were tested in clinical settings and in the laboratory. Actual human breath screening studies were carried out with healthy volunteers, inebriated homeless men, emergency room patients and methanol-intoxicated patients. A number of the breath analysis results were compared to blood test results in order to approximate the blood-breath relationship. In the laboratory experiments, the analytical performance of the Gasmet FT-IR analyzer and Dräger 7110 evidential breath analyzer was evaluated by means of artificial samples resembling exhaled breath. The investigations demonstrated that a successful breath ethanol analysis by Dräger 7110 evidential breath analyzer could exclude any significant methanol intoxication. In contrast, the device did not detect very high levels of acetone, 1-propanol and 2-propanol in simulated breath. The Dräger 7110 evidential breath ethanol analyzer was not equipped to recognize the interfering component. According to the studies the Gasmet FT-IR analyzer was adequately sensitive, selective and accurate for solvent intoxication diagnostics. In addition to diagnostics, the fast breath solvent analysis proved feasible for controlling the ethanol and methanol concentration during haemodialysis treatment. Because of the simplicity of the sampling and analysis procedure, non-laboratory personnel, such as police officers or social workers, could also operate the analyzer for screening purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to develop and test new digital imaging equipment and methods for diagnosis and follow-up of ocular diseases. Methods: The whole material comprised 398 subjects (469 examined eyes), including 241 patients with melanocytic choroidal tumours, 56 patients with melanocytic iris tumours, 42 patients with diabetes, a 52-year old patient with chronic phase of VKH disease, a 30-year old patient with an old blunt eye injury, and 57 normal healthy subjects. Digital 50° (Topcon TRC 50 IA) and 45° (Canon CR6-45NM) fundus cameras, a new handheld digital colour videocamera for eye examinations (MediTell), a new subtraction method using the Topcon Image Net Program (Topcon corporation, Tokyo, Japan), a new method for digital IRT imaging of the iris we developed, and Zeiss photoslitlamp with a digital camera body were used for digital imaging. Results: Digital 50° red-free imaging had a sensitivity of 97.7% and two-field 45° and 50° colour imaging a sensitivity of 88.9-94%. The specificity of the digital 45°-50° imaging modalities was 98.9-100% versus the reference standard and ungradeable images that were 1.2-1.6%. By using the handheld digital colour video camera only, the optic disc and central fundus located inside 20° from the fovea could be recorded with a sensitivity of 6.9% for detection of at least mild NPDR when compared with the reference standard. Comparative use of digital colour, red-free, and red light imaging showed 85.7% sensitivity, 99% specificity, and 98.2 % exact agreement versus the reference standard in differentiation of small choroidal melanoma from pseudomelanoma. The new subtraction method showed growth in four of 94 melanocytic tumours (4.3%) during a mean ±SD follow-up of 23 ± 11 months. The new digital IRT imaging of the iris showed the sphincter muscle and radial contraction folds of Schwalbe in the pupillary zone and radial structural folds of Schwalbe and circular contraction furrows in the ciliary zone of the iris. The 52-year-old patient with a chronic phase of VKH disease showed extensive atrophy and occasional pigment clumps in the iris stroma, detachment of the ciliary body with severe ocular hypotony, and shallow retinal detachment of the posterior pole in both eyes. Infrared transillumination imaging and fluorescein angiographic findings of the iris showed that IR translucence (p=0.53), complete masking of fluorescence (p=0.69), presence of disorganized vessels (p=0.32), and fluorescein leakage (p=1.0) at the site of the lesion did not differentiate an iris nevus from a melanoma. Conclusions: Digital 50° red-free and two-field 50° or 45° colour imaging were suitable for DR screening, whereas the handheld digital video camera did not fulfill the needs of DR screening. Comparative use of digital colour, red-free and red light imaging was a suitable method in the differentiation of small choroidal melanoma from different pseudomelanomas. The subtraction method may reveal early growth of the melanocytic choroidal tumours. Digital IRT imaging may be used to study changes of the stroma and posterior surface of the iris in various diseases of the uvea. It contributed to the revealment of iris atrophy and serous detachment of the ciliary body with ocular hypotony together with the shallow retinal detachment of the posterior pole as new findings of the chronic phase of VKH disease. Infrared translucence and angiographic findings are useful in differential diagnosis of melanocytic iris tumours, but they cannot be used to determine if the lesion is benign or malignant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interstellar clouds are not featureless, but show quite complex internal structures of filaments and clumps when observed with high enough resolution. These structures have been generated by 1) turbulent motions driven mainly by supernovae, 2) magnetic fields working on the ions and, through neutral-ion collisions, on neutral gas as well, and 3) self-gravity pulling a dense clump together to form a new star. The study of the cloud structure gives us information on the relative importance of each of these mechanisms, and helps us to gain a better understanding of the details of the star formation process. Interstellar dust is often used as a tracer for the interstellar gas which forms the bulk of the interstellar matter. Some of the methods that are used to derive the column density are summarized in this thesis. A new method, which uses the scattered light to map the column density in large fields with high spatial resolution, is introduced. This thesis also takes a look at the grain alignment with respect to the magnetic fields. The aligned grains give rise to the polarization of starlight and dust emission, thus revealing the magnetic field. The alignment mechanisms have been debated for the last half century. The strongest candidate at present is the radiative torques mechanism. In the first four papers included in this thesis, the scattered light method of column density estimation is formulated, tested in simulations, and finally used to obtain a column density map from observations. They demonstrate that the scattered light method is a very useful and reliable tool in column density estimation, and is able to provide higher resolution than the near-infrared color excess method. These two methods are complementary. The derived column density maps are also used to gain information on the dust emissivity within the observed cloud. The two final papers present simulations of polarized thermal dust emission assuming that the alignment happens by the radiative torques mechanism. We show that the radiative torques can explain the observed decline of the polarization degree towards dense cores. Furthermore, the results indicate that the dense cores themselves might not contribute significantly to the polarized signal, and hence one needs to be careful when interpreting the observations and deriving the magnetic field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method for absolute frequency measurements of molecular transitions in the mid-infrared region is reported. The method is based on a cw singly-resonant optical parametric oscillator (SRO), which is tunable from 3.2 to 3.45 µm. The mid- infrared frequency of the SRO is referenced to an optical frequency comb through its pump and signal beams. Sub-Doppler spectroscopy and absolute frequency measurement of the P(7) transition of the ν3 band of CH4 are demonstrated.