2 resultados para Geopolymer paste

em Helda - Digital Repository of University of Helsinki


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this series of studies was to evaluate the biocompatibility of poly (ortho) ester (POE), copolymer of ε-caprolactone and D,L-lactide [P (ε-CL/DL-LA)] and the composite of P(ε-CL/DL-LA) and tricalciumphosphate (TCP) as bone filling material in bone defects. Tissue reactions and resorption times of two solid POE-implants (POE 140 and POE 46) with different methods of sterilization (gamma- and ethylene oxide sterilization), P(ε-CL/DL-LA)(40/60 w/w) in paste form and 50/50 w/w composite of 40/60 w/w P(ε-CL/DL-LA) and TCP and 27/73 w/w composite of 60/40 w/w P(ε-CL/DL-LA) and TCP were examined in experimental animals. The follow-up times were from one week to 52 weeks. The bone samples were evaluated histologically and the soft tissue samples histologically, immunohistochemically and electronmicroscopically. The results showed that the resorption time of gamma sterilized POE 140 was eight weeks and ethylene oxide sterilized POE 140 13 weeks in bone. The resorption time of POE 46 was more than 24 weeks. The gamma sterilized rods started to erode from the surface faster than ethylene oxide sterilized rods for both POEs. Inflammation in bone was from slight to moderate with POE 140 and moderate with POE 46. No highly fluorescent layer of tenascin or fibronectin was found in the soft tissue. Bone healing at the sites of implantation was slower than at control sites with the copolymer in small bone defects. The resorption time for the copolymer was over one year. Inflammation in bone was mostly moderate. Bone healing at the sites of implantation was also slower than at the control sites with the composite in small and large mandibular bone defects. Bone formation had ceased at both sites by the end of follow-up in large mandibular bone defects. The ultrastructure of the connective tissue was normal during the period of observation. It can be concluded that the method of sterilization influenced the resorption time of both POEs. Gamma sterilized POE 140 could have been suitable material for filling small bone defects, whereas the degradation times of solid EO-sterilized POE 140 and POE 46 were too slow to be considered as bone filling material. Solid material is difficult to contour, which can be considered as a disadvantage. The composites were excellent to handle, but the degradation time of the polymer and the composites were too slow. Therefore, the copolymer and the composite can not be recommended as bone filling material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this dissertation was to study the applicability of minced autologous fascia graft for injection laryngoplasty of unilateral vocal fold paralysis (UVFP). Permanence of augmentation and host versus graft tissue reactions were of special interest. The topic deals with phonosurgery, which is a subdivision of the Ear, Nose and Throat-speciality of medicine. UVFP results from an injury to the recurrent or the vagal nerve. The main symptom is a hoarse and weak voice. Surgery is warranted for patients in whom spontaneous reinnervation and a course of voice therapy fails to improve the voice. Injection laryngoplasty is a widespread surgical technique which aims to restore glottic closure by augmenting the atrophied vocal muscle, and also by turning the paralyzed vocal fold towards midline. Currently, there exists a great diversity of synthetic, xenologous, homologous, and autologous substances available for injection. An autologous graft is perfect in terms of biocompatibility. Free fascia grafts have been successfully used in the head and neck surgery for decades, but fascia had not been previously applied into the vocal fold. The fascia is harvested from the lateral thigh under local anesthesia and minced into paste by scissors. Injection of the vocal fold is performed in laryngomicroscopy under general anesthesia. Three series of clinical trials of injection laryngoplasty with autologous fascia (ILAF) for patients with UVFP were conducted at the Department of Otorhinolaryngology of the Helsinki University Central Hospital. The follow-up ranged from a few months to ten years. The aim was to document the vocal results and possible morbidity related to graft harvesting and vocal fold injection. To address the tissue reactions and the degree of reabsoprtion of the graft, an animal study with a follow-up ranging from 3 days to 12 months was performed at the National Laboratory Animal Center, University of Kuopio. Harvesting of the graft and injection was met with minor morbidity. Histological analysis of the vocal fold tissue showed that fascia was well tolerated. Although some resorption or compaction of the graft during the first months is evident, graft volume is maintained well. When injected deep and laterally into the vocalis muscle, the fascia graft allows normal vibration of the vocal fold mucosa to occur during phonation. Improvement of voice quality was seen in all series by multiple objective parameters of voice evaluation. However, the vocal results were poor in cases where the nerve trauma was severe, such as UVFP after chest surgery. ILAF is most suitable for correction of mild to moderate glottic gaps related to less severe nerve damage. Our results indicate that autologous fascia is a feasible and safe new injection material with good and stable vocal results. It offers a practical solution for surgeons who treat this complex issue.