29 resultados para Chromatographic techniques
em Helda - Digital Repository of University of Helsinki
Development of Sample Pretreatment and Liquid Chromatographic Techniques for Antioxidative Compounds
Resumo:
In this study, novel methodologies for the determination of antioxidative compounds in herbs and beverages were developed. Antioxidants are compounds that can reduce, delay or inhibit oxidative events. They are a part of the human defense system and are obtained through the diet. Antioxidants are naturally present in several types of foods, e.g. in fruits, beverages, vegetables and herbs. Antioxidants can also be added to foods during manufacturing to suppress lipid oxidation and formation of free radicals under conditions of cooking or storage and to reduce the concentration of free radicals in vivo after food ingestion. There is growing interest in natural antioxidants, and effective compounds have already been identified from antioxidant classes such as carotenoids, essential oils, flavonoids and phenolic acids. The wide variety of sample matrices and analytes presents quite a challenge for the development of analytical techniques. Growing demands have been placed on sample pretreatment. In this study, three novel extraction techniques, namely supercritical fluid extraction (SFE), pressurised hot water extraction (PHWE) and dynamic sonication-assisted extraction (DSAE) were studied. SFE was used for the extraction of lycopene from tomato skins and PHWE was used in the extraction of phenolic compounds from sage. DSAE was applied to the extraction of phenolic acids from Lamiaceae herbs. In the development of extraction methodologies, the main parameters of the extraction were studied and the recoveries were compared to those achieved by conventional extraction techniques. In addition, the stability of lycopene was also followed under different storage conditions. For the separation of the antioxidative compounds in the extracts, liquid chromatographic methods (LC) were utilised. Two novel LC techniques, namely ultra performance liquid chromatography (UPLC) and comprehensive two-dimensional liquid chromatography (LCxLC) were studied and compared with conventional high performance liquid chromatography (HPLC) for the separation of antioxidants in beverages and Lamiaceae herbs. In LCxLC, the selection of LC mode, column dimensions and flow rates were studied and optimised to obtain efficient separation of the target compounds. In addition, the separation powers of HPLC, UPLC, HPLCxHPLC and HPLCxUPLC were compared. To exploit the benefits of an integrated system, in which sample preparation and final separation are performed in a closed unit, dynamic sonication-assisted extraction was coupled on-line to a liquid chromatograph via a solid-phase trap. The increased sensitivity was utilised in the extraction of phenolic acids from Lamiaceae herbs. The results were compared to those of achieved by the LCxLC system.
Resumo:
Miniaturized mass spectrometric ionization techniques for environmental analysis and bioanalysis Novel miniaturized mass spectrometric ionization techniques based on atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were studied and evaluated in the analysis of environmental samples and biosamples. The three analytical systems investigated here were gas chromatography-microchip atmospheric pressure chemical ionization-mass spectrometry (GC-µAPCI-MS) and gas chromatography-microchip atmospheric pressure photoionization-mass spectrometry (GC-µAPPI-MS), where sample pretreatment and chromatographic separation precede ionization, and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS), where the samples are analyzed either as such or after minimal pretreatment. The gas chromatography-microchip atmospheric pressure ionization-mass spectrometry (GC-µAPI-MS) instrumentations were used in the analysis of polychlorinated biphenyls (PCBs) in negative ion mode and 2-quinolinone-derived selective androgen receptor modulators (SARMs) in positive ion mode. The analytical characteristics (i.e., limits of detection, linear ranges, and repeatabilities) of the methods were evaluated with PCB standards and SARMs in urine. All methods showed good analytical characteristics and potential for quantitative environmental analysis or bioanalysis. Desorption and ionization mechanisms in DAPPI were studied. Desorption was found to be a thermal process, with the efficiency strongly depending on thermal conductivity of the sampling surface. Probably the size and polarity of the analyte also play a role. In positive ion mode, the ionization is dependent on the ionization energy and proton affinity of the analyte and the spray solvent, while in negative ion mode the ionization mechanism is determined by the electron affinity and gas-phase acidity of the analyte and the spray solvent. DAPPI-MS was tested in the fast screening analysis of environmental, food, and forensic samples, and the results demonstrated the feasibility of DAPPI-MS for rapid screening analysis of authentic samples.
Resumo:
The feasibility of different modern analytical techniques for the mass spectrometric detection of anabolic androgenic steroids (AAS) in human urine was examined in order to enhance the prevalent analytics and to find reasonable strategies for effective sports drug testing. A comparative study of the sensitivity and specificity between gas chromatography (GC) combined with low (LRMS) and high resolution mass spectrometry (HRMS) in screening of AAS was carried out with four metabolites of methandienone. Measurements were done in selected ion monitoring mode with HRMS using a mass resolution of 5000. With HRMS the detection limits were considerably lower than with LRMS, enabling detection of steroids at low 0.2-0.5 ng/ml levels. However, also with HRMS, the biological background hampered the detection of some steroids. The applicability of liquid-phase microextraction (LPME) was studied with metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol. Factors affecting the extraction process were studied and a novel LPME method with in-fiber silylation was developed and validated for GC/MS analysis of the danazol metabolite. The method allowed precise, selective and sensitive analysis of the metabolite and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine without any other steps in sample preparation. Liquid chromatographic/tandem mass spectrometric (LC/MS/MS) methods utilizing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were developed and applied for detection of oxandrolone and metabolites of stanozolol and 4-chlorodehydromethyltestosterone in urine. All methods exhibited high sensitivity and specificity. ESI showed, however, the best applicability, and a LC/ESI-MS/MS method for routine screening of nine 17-alkyl-substituted AAS was thus developed enabling fast and precise measurement of all analytes with detection limits below 2 ng/ml. The potential of chemometrics to resolve complex GC/MS data was demonstrated with samples prepared for AAS screening. Acquired full scan spectral data (m/z 40-700) were processed by the OSCAR algorithm (Optimization by Stepwise Constraints of Alternating Regression). The deconvolution process was able to dig out from a GC/MS run more than the double number of components as compared with the number of visible chromatographic peaks. Severely overlapping components, as well as components hidden in the chromatographic background could be isolated successfully. All studied techniques proved to be useful analytical tools to improve detection of AAS in urine. Superiority of different procedures is, however, compound-dependent and different techniques complement each other.
Resumo:
The present challenge in drug discovery is to synthesize new compounds efficiently in minimal time. The trend is towards carefully designed and well-characterized compound libraries because fast and effective synthesis methods easily produce thousands of new compounds. The need for rapid and reliable analysis methods is increased at the same time. Quality assessment, including the identification and purity tests, is highly important since false (negative or positive) results, for instance in tests of biological activity or determination of early-ADME parameters in vitro (the pharmacokinetic study of drug absorption, distribution, metabolism, and excretion), must be avoided. This thesis summarizes the principles of classical planar chromatographic separation combined with ultraviolet (UV) and mass spectrometric (MS) detection, and introduces powerful, rapid, easy, low-cost, and alternative tools and techniques for qualitative and quantitative analysis of small drug or drug-like molecules. High performance thin-layer chromatography (HPTLC) was introduced and evaluated for fast semi-quantitative assessment of the purity of synthesis target compounds. HPTLC methods were compared with the liquid chromatography (LC) methods. Electrospray ionization mass spectrometry (ESI MS) and atmospheric pressure matrix-assisted laser desorption/ionization MS (AP MALDI MS) were used to identify and confirm the product zones on the plate. AP MALDI MS was rapid, and easy to carry out directly on the plate without scraping. The PLC method was used to isolate target compounds from crude synthesized products and purify them for bioactivity and preliminary ADME tests. Ultra-thin-layer chromatography (UTLC) with AP MALDI MS and desorption electrospray ionization mass spectrometry (DESI MS) was introduced and studied for the first time. Because of the thinner adsorbent layer, the monolithic UTLC plate provided 10 100 times better sensitivity in MALDI analysis than did HPTLC plates. The limits of detection (LODs) down to low picomole range were demonstrated for UTLC AP MALDI and UTLC DESI MS. In a comparison of AP and vacuum MALDI MS detection for UTLC plates, desorption from the irregular surface of the plates with the combination of an external AP MALDI ion source and an ion trap instrument provided clearly less variation in mass accuracy than the vacuum MALDI time-of-flight (TOF) instrument. The performance of the two-dimensional (2D) UTLC separation with AP MALDI MS method was studied for the first time. The influence of the urine matrix on the separation and the repeatability was evaluated with benzodiazepines as model substances in human urine. The applicability of 2D UTLC AP MALDI MS was demonstrated in the detection of metabolites in an authentic urine sample.
Resumo:
This study is based on the multidiciplinary approach of using natural colorants as textile dyes. The author was interested in both the historical and traditional aspects of natural dyeing as well as the modern industrial applications of the pure natural compounds. In the study, the anthraquinone compounds were isolated as aglycones from the ectomycorrhizal fungus Dermocybe sanguinea. The endogenous beta-glucosidase of the fungus was used to catalyse the hydrolysis of the O-glycosyl linkage in emodin- and dermocybin-1-beta-D-glucopyranosides. The method, in which 10.45 kg of fresh fungi was starting material, yielded two fractions: 56.0 g of Fraction 1 (94% of the total amount of pigment,) consisting almost exclusively of the main pigments emodin and dermocybin, and 3.3 g of Fraction 2 (6%) consisting mainly of the anthraquinone carboxylic acids. The anthraquinone compounds in Fractions 1 and 2 were separated by one- and two-dimensional thin-layer-chromatography (TLC) using silica plates. 1D TLC showed that neither an acidic nor a basic solvent system alone separated completely all the anthraquinones isolated from D. sanguinea, in spite of the variation of the rations of the solvent components in the systems. Thus, a new 2D TLC technique was developed, applying n-pentanol-pyridine-methanol (6:4:3, v/v/v) and toluene-ethyl acetate-ethanol-formic acid (10:8:1:2, v/v/v/v) as eluents. Fifteen different anthraquinone derivatives were completely separated from one another. Emodin, physcion, endocrocin, dermolutein, dermorubin, 5-chlorodermorubin, emodin-1-beta-D-glucopyranoside, dermocybin-1-beta-D-glucopyranoside and dermocybin, and five new compounds, not earlier identified in D. sanguinea, 7-chloroemodin, 5,7-dichloroemodin, 5,7-dichloroendocrocin, 4-hydroxyaustrocorticone and austrocorticone, were separated and identified on the basis of their Rf-values, UV/Vis spectra and mass spectra. One substance remained unidentified, because of its very low concentration. The anthraquinones in Fractions 1 and 2 were preparatively separeted by liquid-liquid partition, with isopropylmethyl ketone and aqueous phosphate buffer as the solvent system. Advantage was taken of the principle of stepwise pH-gradient elution. The multiple liquid-liquid partition (MLLP) offered an excellent method for the preparative separation of compounds, which contain acidic groups such as the phenolic OH and COOH groups. Due to their strong aggregation properties, these compounds are, without derivatization, very difficult to separate on a preparative scale by chromatographic methods. By the MLLP method remarkable separations were achieved for the components in each mixture. Emodin and dermocybin were both obtained from Fraction 1 in a purity of at least 99%. Pure emodin and dermocybin were applied as mordant dyes to wool and polyamide and as disperse dyes to polyester and polyamide, using the high temperature (HT) technique. A mixture of dermorubin and 5-chlorodermorubin was applied as an acid dye to wool. In these experiments, synthetic dyes were used as references. Experiments were also performed using water extract of the air-dried fungi as dye liquor for wool and silk. The main colouring compounds in the crude water extract were emodin and dermocybin, which indicated that the O-glycosyl linkages in emodin- and dermocybin-1-beta-D-glucopyranosides were broken by the beta-glucosidase enzyme. Apparently, the hydrolysis occurred during the drying of the fungi and during the soaking of the dried fruit bodies overnight when preparing the dyebath. The colour of each dyed material was investigated in terms of the CIELAB L*, a* and b* values, and the colour fastness to light, washing and rubbing was tested according to the ISO standards. In the mordant dyeing experiments, emodin dyed wool and polyamide yellow and red, depending on the pH of the dyebath. Dermocybin gave purple and violet colours. The colour fastness of the mordant-dyed fabrics varied from good to moderate. The fastness properties of the natural anthraquinone carboxylic acids on wool were good, indicating the strength of the ionic bonds between the COO- groups of the dyes and the NH3+ groups of the fibres. In the disperse dyeing experiments, emodin dyed polyester bright yellow and dermocybin bright reddish-orange, and the fabrics showed excellent colour fastness. In contrast, emodin and dermocybin successfully dyed polyamide brownish-orange and wine-red, respectively, but with only moderate fastness. In industrial dyeing processes, natural anthraquinone aglycone mixtures dyed wool and silk well even at low concentrations of mordants, i.e. with 10% of the weight of the fibre (owf) of KAl(SO4)2 and 1 or 0.5% owf of other mordants. This study showed that purified natural anthraquinone compounds can produce bright hues with good colour-fastness properties in different textile materials. Natural anthraquinones have a significant potential for new dyeing techniques and will provide useful alternatives to synthetic dyes.
Resumo:
The average daily intake of folate, one of the B vitamins, falls below recommendations among the Finnish population. Bread and cereals are the main sources of folate, rye being the most significant single source. Processing is a prerequisite for the consumption of whole grain rye; however, little is known about the effect of processing on folates. Moreover, data on the bioavailability of endogenous cereal folates are scarce. The aim of this study was to examine the variation in as well as the effect of fermentation, germination, and thermal processes on folate contents in rye. Bioavailability of endogenous rye folates was investigated in a four-week human intervention study. One of the objectives throughout the work was to optimise and evaluate analytical methods for determining folate contents in cereals. Affinity chromatographic purification followed by high-performance liquid chromatography (HPLC) was a suitable method for analysing cereal products for folate vitamers, and microbiological assay with Lactobacillus rhamnosus reliably quantified the total folate. However, HPLC gave approximately 30% lower results than the microbiological assay. The folate content of rye was high and could be further increased by targeted processing. The vitamer distribution of whole grain rye was characterised by a large proportion of formylated vitamers followed by 5-methyltetrahydrofolate. In sourdough fermentation of rye, the studied yeasts synthesized and lactic acid bacteria mainly depleted folate. Two endogenous bacteria isolated from rye flour were found to produce folate during fermentation. Inclusion of baker s yeast in sourdough fermentation raised the folate level so that the bread could contain more folate than the flour it was made of. Germination markedly increased the folate content of rye, with particularly high folate concentrations in hypocotylar roots. Thermal treatments caused significant folate losses but the preceding germination compensated well for the losses. In the bioavailability study, moderate amounts of endogenous folates in the form of different rye products and orange juice incorporated in the diet improved the folate status among healthy adults. Endogenous folates from rye and orange juice showed similar bioavailability to folic acid from fortified white bread. In brief, it was shown that the folate content of rye can be enhanced manifold by optimising and combining food processing techniques. This offers some practical means to increase the daily intake of folate in a bioavailable form.
Resumo:
Standards have been placed to regulate the microbial and preservative contents to assure that foods are safe to the consumer. In a case of a food-related disease outbreak, it is crucial to be able to detect and identify quickly and accurately the cause of the disease. In addition, for every day control of food microbial and preservative contents, the detection methods must be easily performed for numerous food samples. In this present study, quicker alternative methods were studied for identification of bacteria by DNA fingerprinting. A flow cytometry method was developed as an alternative to pulsed-field gel electrophoresis, the golden method . DNA fragment sizing by an ultrasensitive flow cytometer was able to discriminate species and strains in a reproducible and comparable manner to pulsed-field gel electrophoresis. This new method was hundreds times faster and 200,000 times more sensitive. Additionally, another DNA fingerprinting identification method was developed based on single-enzyme amplified fragment length polymorphism (SE-AFLP). This method allowed the differentiation of genera, species, and strains of pathogenic bacteria of Bacilli, Staphylococci, Yersinia, and Escherichia coli. These fingerprinting patterns obtained by SE-AFLP were simpler and easier to analyze than those by the traditional amplified fragment length polymorphism by double enzyme digestion. Nisin (E234) is added as a preservative to different types of foods, especially dairy products, around the world. Various detection methods exist for nisin, but they lack in sensitivity, speed or specificity. In this present study, a sensitive nisin-induced green fluorescent protein (GFPuv) bioassay was developed using the Lactococcus lactis two-component signal system NisRK and the nisin-inducible nisA promoter. The bioassay was extremely sensitive with detection limit of 10 pg/ml in culture supernatant. In addition, it was compatible for quantification from various food matrices, such as milk, salad dressings, processed cheese, liquid eggs, and canned tomatoes. Wine has good antimicrobial properties due to its alcohol concentration, low pH, and organic content and therefore often assumed to be microbially safe to consume. Another aim of this thesis was to study the microbiota of wines returned by customers complaining of food-poisoning symptoms. By partial 16S rRNA gene sequence analysis, ribotyping, and boar spermatozoa motility assay, it was identified that one of the wines contained a Bacillus simplex BAC91, which produced a heat-stable substance toxic to the mitochondria of sperm cells. The antibacterial activity of wine was tested on the vegetative cells and spores of B. simplex BAC91, B. cereus type strain ATCC 14579 and cereulide-producing B. cereus F4810/72. Although the vegetative cells and spores of B. simplex BAC91 were sensitive to the antimicrobial effects of wine, the spores of B. cereus strains ATCC 14579 and F4810/72 stayed viable for at least 4 months. According to these results, Bacillus spp., more specifically spores, can be a possible risk to the wine consumer.
Resumo:
Determination of testosterone and related compounds in body fluids is of utmost importance in doping control and the diagnosis of many diseases. Capillary electromigration techniques are a relatively new approach for steroid research. Owing to their electrical neutrality, however, separation of steroids by capillary electromigration techniques requires the use of charged electrolyte additives that interact with the steroids either specifically or non-specifically. The analysis of testosterone and related steroids by non-specific micellar electrokinetic chromatography (MEKC) was investigated in this study. The partial filling (PF) technique was employed, being suitable for detection by both ultraviolet spectrophotometry (UV) and electrospray ionization mass spectrometry (ESI-MS). Efficient, quantitative PF-MEKC UV methods for steroid standards were developed through the use of optimized pseudostationary phases comprising surfactants and cyclodextrins. PF-MEKC UV proved to be a more sensitive, efficient and repeatable method for the steroids than PF-MEKC ESI-MS. It was discovered that in PF-MEKC analyses of electrically neutral steroids, ESI-MS interfacing sets significant limitations not only on the chemistry affecting the ionization and detection processes, but also on the separation. The new PF-MEKC UV method was successfully employed in the determination of testosterone in male urine samples after microscale immunoaffinity solid-phase extraction (IA-SPE). The IA-SPE method, relying on specific interactions between testosterone and a recombinant anti-testosterone Fab fragment, is the first such method described for testosterone. Finally, new data for interactions between steroids and human and bovine serum albumins were obtained through the use of affinity capillary electrophoresis. A new algorithm for the calculation of association constants between proteins and neutral ligands is introduced.
Resumo:
Radioactive particles from three locations were investigated for elemental composition, oxidation states of matrix elements, and origin. Instrumental techniques applied to the task were scanning electron microscopy, X-ray and gamma-ray spectrometry, secondary ion mass spectrometry, and synchrotron radiation based microanalytical techniques comprising X-ray fluorescence spectrometry, X-ray fluorescence tomography, and X-ray absorption near-edge structure spectroscopy. Uranium-containing low activity particles collected from Irish Sea sediments were characterized in terms of composition and distribution of matrix elements and the oxidation states of uranium. Indications of the origin were obtained from the intensity ratios and the presence of thorium, uranium, and plutonium. Uranium in the particles was found to exist mostly as U(IV). Studies on plutonium particles from Runit Island (Marshall Islands) soil indicated that the samples were weapon fuel fragments originating from two separate detonations: a safety test and a low-yield test. The plutonium in the particles was found to be of similar age. The distribution and oxidation states of uranium and plutonium in the matrix of weapon fuel particles from Thule (Greenland) sediments were investigated. The variations in intensity ratios observed with different techniques indicated more than one origin. Uranium in particle matrixes was mostly U(IV), but plutonium existed in some particles mainly as Pu(IV), and in others mainly as oxidized Pu(VI). The results demonstrated that the various techniques were effectively applied in the characterization of environmental radioactive particles. An on-line method was developed for separating americium from environmental samples. The procedure utilizes extraction chromatography to separate americium from light lanthanides, and cation exchange to concentrate americium before the final separation in an ion chromatography column. The separated radiochemically pure americium fraction is measured by alpha spectrometry. The method was tested with certified sediment and soil samples and found to be applicable for the analysis of environmental samples containing a wide range of Am-241 activity. Proceeding from the on-line method developed for americium, a method was also developed for separating plutonium and americium. Plutonium is reduced to Pu(III), and separated together with Am(III) throughout the procedure. Pu(III) and Am(III) are eluted from the ion chromatography column as anionic dipicolinate and oxalate complexes, respectively, and measured by alpha spectrometry.
Application of Modern NMR Spectroscopic Techniques to Structural Studies of Wood and Pulp Components