4 resultados para 480
em Helda - Digital Repository of University of Helsinki
Resumo:
Dietary habits have changed during the past decades towards an increasing consumption of processed foods, which has notably increased not only total dietary phosphorus (P) intake, but also intake of P from phosphate additives. While the intake of calcium (Ca) in many Western countries remains below recommended levels (800 mg/d), the usual daily P intake in a typical Western diet exceeds by 2- to 3-fold the dietary guidelines (600 mg/d). The effects of high P intake in healthy humans have been investigated seldom. In this thesis healthy 20- to 43-year-old women were studied. In the first controlled study (n = 14), we examined the effects of P doses, and in a cross-sectional study (n = 147) the associations of habitual P intakes with Ca and bone metabolism. In this same cross-sectional study, we also investigated whether differences exist between dietary P originating from natural P sources and phosphate additives. The second controlled study (n = 12) investigated whether by increasing the Ca intake, the effects of a high P intake could be reduced. The associations of habitual dietary calcium-to-phosphorus ratios (Ca:P ratio) with Ca and bone metabolism were determined in a cross-sectional study design (n = 147). In the controlled study, the oral intake of P doses (495, 745, 1245 and 1995 mg/d) with a low Ca intake (250 mg/d) increased serum parathyroid hormone (S-PTH) concentration in a dose-dependent manner. In addition, the highest P dose decreased serum ionized calcium (S-iCa) concentration and bone formation and increased bone resorption. In the second controlled study with a dietary P intake of 1850 mg/d, by increasing the Ca intake from 480 mg/d to 1080 mg/d and then to 1680 mg/d, the S-PTH concentration decreased, the S-iCa concentration increased and bone resorption decreased dose-dependently. However, not even the highest Ca intake could counteract the effect of high dietary P on bone formation, as indicated by unchanged bone formation activity. In the cross-sectional studies, a higher habitual dietary P intake (>1650 mg/d) was associated with lower S-iCa and higher S-PTH concentrations. The consumption of phosphate additive-containing foods was associated with a higher S-PTH concentration. Moreover, habitual low dietary Ca:P ratios (≤0.50, molar ratio) were associated with higher S-PTH concentrations and 24-h urinary Ca excretions, suggesting that low dietary Ca:P ratios may interfere with homeostasis of Ca metabolism and increase bone resorption. In summary, excessive dietary P intake in healthy Finnish women seems to be detrimental to Ca and bone metabolism, especially when dietary Ca intake is low. The results indicate that by increasing dietary Ca intake to the recommended level, the negative effects of high P intake could be diminished, but not totally prevented. These findings imply that phosphate additives may be more harmful than natural P. Thus, reduction of an excessively high dietary P intake is also beneficial for healthy individuals.
Resumo:
The methods for estimating patient exposure in x-ray imaging are based on the measurement of radiation incident on the patient. In digital imaging, the useful dose range of the detector is large and excessive doses may remain undetected. Therefore, real-time monitoring of radiation exposure is important. According to international recommendations, the measurement uncertainty should be lower than 7% (confidence level 95%). The kerma-area product (KAP) is a measurement quantity used for monitoring patient exposure to radiation. A field KAP meter is typically attached to an x-ray device, and it is important to recognize the effect of this measurement geometry on the response of the meter. In a tandem calibration method, introduced in this study, a field KAP meter is used in its clinical position and calibration is performed with a reference KAP meter. This method provides a practical way to calibrate field KAP meters. However, the reference KAP meters require comprehensive calibration. In the calibration laboratory it is recommended to use standard radiation qualities. These qualities do not entirely correspond to the large range of clinical radiation qualities. In this work, the energy dependence of the response of different KAP meter types was examined. According to our findings, the recommended accuracy in KAP measurements is difficult to achieve with conventional KAP meters because of their strong energy dependence. The energy dependence of the response of a novel large KAP meter was found out to be much lower than with a conventional KAP meter. The accuracy of the tandem method can be improved by using this meter type as a reference meter. A KAP meter cannot be used to determine the radiation exposure of patients in mammography, in which part of the radiation beam is always aimed directly at the detector without attenuation produced by the tissue. This work assessed whether pixel values from this detector area could be used to monitor the radiation beam incident on the patient. The results were congruent with the tube output calculation, which is the method generally used for this purpose. The recommended accuracy can be achieved with the studied method. New optimization of radiation qualities and dose level is needed when other detector types are introduced. In this work, the optimal selections were examined with one direct digital detector type. For this device, the use of radiation qualities with higher energies was recommended and appropriate image quality was achieved by increasing the low dose level of the system.
Resumo:
This paper analyses the impact of the launch of the European Monetary Union (EMU) on the allocation of international portfolio investments. The initiation of the EMU provides an opportunity for comparison of competing theoretical explanations for investment behavior. Models stressing the diversification motive would predict that the increased dependence between countries participating in the EMU should reduce the attractiveness of portfolio holdings in other EMU countries. Models based on asymmetric information would instead emphasize the increased intensity in the flow of information resulting from an increase in cross border transactions between the EMU countries. The consequent decline in information asymmetry should increase, rather than reduce portfolio holdings in other EMU countries. Our results based on the allocation of Finnish foreign portfolio investment support the information-based explanation against predictions based on the diversification motive.
Resumo:
Suomessa on viime vuosina keskusteltu 1900-luvun historiamme eräiden vaiheiden moraalisesta (uudelleen)arvioinnista. Tällöin on myös väitelty siitä, pitäisikö jonkin tahon esimerkiksi pyytää anteeksi mahdollisia tehtyjä vääryyksiä. Tässä artikkelissa tarkastellaan suomalaisnuorten ajatuksia historiallisista hyvityksistä, tulkitaan niitä suhteessa suomalaisnuorten historiatietoisuutta koskevaan aiempaan tutkimukseen sekä pohditaan lyhyesti havaintojen historiandidaktisia implikaatioita.