2 resultados para 1 Corinthians 13:12

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. In Finland, the incidence of type 1 diabetes mellitus (T1DM) is the highest in the world, and it continues to increase steadily. No effective preventative interventions exist either for individuals at high risk or for the population as a whole. In addition to problems with daily lifelong insulin replacement therapy, T1DM patients with long-lasting disease suffer from various diabetes related complications. The complications can lead to severe impairments and reductions in functional capacity and quality of life and in the worst case they can be fatal. Longitudinal studies on the costs of T1DM are extremely rare, especially in Finland. Typically, in these studies, distinctions between the various types of diabetes have not been made, and costs have not been calculated separately for the sexes. Aims. The aim of this study was to describe inpatient hospital care and costs of inpatient care in a cohort of 5,166 T1DM patients by sex during 1973-1998 in Finland. Inpatient care and costs of care due to T1DM without complications, due to T1DM with complications and due to other causes were calculated separately. Material and Methods. The study population consisted of all Finnish T1DM patients diagnosed before the age of 18 years between January 1st in 1965 and December 31st in 1979 and derived from the Finnish population based T1DM register (N=5,120 in 1979 and N=4,701 in 1997). Data on hospitalisations were obtained from the Finnish Hospital Discharge Register. Results. In the early stages of T1DM, the majority of the use of inpatient care was due to the treatment of T1DM without complications. There were enormous increases in the use of inpatient care for certain complications when T1DM lasted longer (from 9.5 years to 16.5 years). For women, the yearly number of bed-days for renal complications increased 4.8-fold, for peripheral vascular disease 4.3-fold and for ophthalmic complications 2.5-fold. For men, the corresponding increases were as follows: 5-fold, 6.9-fold and 2.5-fold. The yearly bed-days for glaucoma increased 8-fold, nephropathy 7-fold and microangiopathy 6-fold in the total population. During these 7 years, the yearly numbers of bed-days for T1DM without complications dropped dramatically. The length of stay in inpatient care decreased notably, but hospital visits became more frequent when the length of duration of T1DM increased from 9.5 years to 16.5 years. The costs of treatments due to complications increased when T1DM lasted longer. Costs due to inpatient care of complications in the cohort 2.5-folded as duration of T1DM increased from 9.5 years to 16.5 years, while the total costs of inpatient care in the cohort dropped by 22% due to an 80% decrease in the costs of care of T1DM without complications. Treating complications of female patients was more expensive than treating complications of men when T1DM had lasted 9.5 years; the mean annual costs for inpatient care of a female diabetic (any cause) were 1,642 , and the yearly costs of care of complications were 237 . The corresponding yearly mean costs for a male patient were 1,198 and 167 . Treating complications of female patients was more expensive than that of male patients also when the duration of diabetes was 16.5 years, although the difference in average annual costs between sexes was somewhat smaller. Conclusions. In the early phases of T1DM, the treatment of T1DM without complications causes a considerable amount of hospital bed-days. The use of inpatient care due to complications of T1DM strongly increases with ageing of patients. The economic burden of inpatient care of T1DM is substantial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research has been prompted by an interest in the atmospheric processes of hydrogen. The sources and sinks of hydrogen are important to know, particularly if hydrogen becomes more common as a replacement for fossil fuel in combustion. Hydrogen deposition velocities (vd) were estimated by applying chamber measurements, a radon tracer method and a two-dimensional model. These three approaches were compared with each other to discover the factors affecting the soil uptake rate. A static-closed chamber technique was introduced to determine the hydrogen deposition velocity values in an urban park in Helsinki, and at a rural site at Loppi. A three-day chamber campaign to carry out soil uptake estimation was held at a remote site at Pallas in 2007 and 2008. The atmospheric mixing ratio of molecular hydrogen has also been measured by a continuous method in Helsinki in 2007 - 2008 and at Pallas from 2006 onwards. The mean vd values measured in the chamber experiments in Helsinki and Loppi were between 0.0 and 0.7 mm s-1. The ranges of the results with the radon tracer method and the two-dimensional model were 0.13 - 0.93 mm s-1 and 0.12 - 0.61 mm s-1, respectively, in Helsinki. The vd values in the three-day campaign at Pallas were 0.06 - 0.52 mm s-1 (chamber) and 0.18 - 0.52 mm s-1 (radon tracer method and two-dimensional model). At Kumpula, the radon tracer method and the chamber measurements produced higher vd values than the two-dimensional model. The results of all three methods were close to each other between November and April, except for the chamber results from January to March, while the soil was frozen. The hydrogen deposition velocity values of all three methods were compared with one-week cumulative rain sums. Precipitation increases the soil moisture, which decreases the soil uptake rate. The measurements made in snow seasons showed that a thick snow layer also hindered gas diffusion, lowering the vd values. The H2 vd values were compared to the snow depth. A decaying exponential fit was obtained as a result. During a prolonged drought in summer 2006, soil moisture values were lower than in other summer months between 2005 and 2008. Such conditions were prevailing in summer 2006 when high chamber vd values were measured. The mixing ratio of molecular hydrogen has a seasonal variation. The lowest atmospheric mixing ratios were found in the late autumn when high deposition velocity values were still being measured. The carbon monoxide (CO) mixing ratio was also measured. Hydrogen and carbon monoxide are highly correlated in an urban environment, due to the emissions originating from traffic. After correction for the soil deposition of H2, the slope was 0.49±0.07 ppb (H2) / ppb (CO). Using the corrected hydrogen-to-carbon-monoxide ratio, the total hydrogen load emitted by Helsinki traffic in 2007 was 261 t (H2) a-1. Hydrogen, methane and carbon monoxide are connected with each other through the atmospheric methane oxidation process, in which formaldehyde is produced as an important intermediate. The photochemical degradation of formaldehyde produces hydrogen and carbon monoxide as end products. Examination of back-trajectories revealed long-range transportation of carbon monoxide and methane. The trajectories can be grouped by applying cluster and source analysis methods. Thus natural and anthropogenic emission sources can be separated by analyzing trajectory clusters.