41 resultados para PROBE 2`,7`-DICHLOROFLUORESCIN
Resumo:
We report the most restrictive direct limits on masses of fourth-generation down-type quarks $b^{\prime}$, and quark-like composite fermions ($B$ or $T_{5/3}$), decaying promptly to $t W^{\mp}$. We search for a significant excess of events with two same-charge leptons ($e$, $\mu$), several hadronic jets, and missing transverse energy. An analysis of data from $p\overline{p}$ collisions with an integrated luminosity of 2.7 fb$^{-1}$ collected with the CDF II detector at Fermilab yields no evidence for such a signal, setting mass limits $m_{b^{\prime}}, m_{B} >$ 338 $\mathrm{GeV}/c^2$ and $m_{T_{5/3}} >$ 365 $\mathrm{GeV}/c^2$ at 95% confidence level.
Resumo:
We report a measurement of the ratio of the tt̅ to Z/γ* production cross sections in √s=1.96 TeV pp̅ collisions using data corresponding to an integrated luminosity of up to 4.6 fb-1, collected by the CDF II detector. The tt̅ cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/γ*→ll cross section predicted by the standard model, the extracted tt̅ cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result σtt̅ =7.70±0.52 pb, for a top-quark mass of 172.5 GeV/c2.
Resumo:
We report a measurement of the ratio of the top-antitop to Z/gamma* production cross sections in sqrt(s) = 1.96 TeV proton-antiproton collisions using data corresponding to an integrated luminosity of up to 4.6 fb-1, collected by the CDF II detector. The top-antitop cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/gamma*->ll cross section, the extracted top-antitop cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result sigma_(top-antitop) = 7.70 +/- 0.52 pb, for a top-quark mass of 172.5 GeV/c^2.
Resumo:
Evidence is reported for a narrow structure near the $J/\psi\phi$ threshold in exclusive $B^+\to J/\psi\phi K^+$ decays produced in $\bar{p} p $ collisions at $\sqrt{s}=1.96 \TeV$. A signal of $14\pm5$ events, with statistical significance in excess of 3.8 standard deviations, is observed in a data sample corresponding to an integrated luminosity of $2.7 \ifb$, collected by the CDF II detector. The mass and natural width of the structure are measured to be $4143.0\pm2.9(\mathrm{stat})\pm1.2(\mathrm{syst}) \MeVcc$ and $11.7^{+8.3}_{-5.0}(\mathrm{stat})\pm3.7(\mathrm{syst}) \MeVcc$.
Resumo:
We present a measurement of the $\ttbar$ differential cross section with respect to the $\ttbar$ invariant mass, dSigma/dMttbar, in $\ppbar$ collisions at $\sqrt{s}=1.96$ TeV using an integrated luminosity of $2.7\invfb$ collected by the CDF II experiment. The $\ttbar$ invariant mass spectrum is sensitive to a variety of exotic particles decaying into $\ttbar$ pairs. The result is consistent with the standard model expectation, as modeled by \texttt{PYTHIA} with \texttt{CTEQ5L} parton distribution functions.
Resumo:
We report a measurement of the top quark mass $M_t$ in the dilepton decay channel $t\bar{t}\to b\ell'^{+}\nu'_\ell\bar{b}\ell^{-}\bar{\nu}_{\ell}$. Events are selected with a neural network which has been directly optimized for statistical precision in top quark mass using neuroevolution, a technique modeled on biological evolution. The top quark mass is extracted from per-event probability densities that are formed by the convolution of leading order matrix elements and detector resolution functions. The joint probability is the product of the probability densities from 344 candidate events in 2.0 fb$^{-1}$ of $p\bar{p}$ collisions collected with the CDF II detector, yielding a measurement of $M_t= 171.2\pm 2.7(\textrm{stat.})\pm 2.9(\textrm{syst.})\mathrm{GeV}/c^2$.
Resumo:
Tutkimuksessa mitataan porsastuotannon tuottavuuden kehitystä ProAgrian sikatilinpäätöstiloilla vuosina 2003–2008. Tuottavuutta mitataan Fisher-tuottavuusindeksillä, joka dekomponoidaan tekniseen, allokatiiviseen ja skaalatehokkuuteen sekä teknologiseen kehitykseen ja hintavaikutukseen. Koko aineistosta aggregoidulla tuottavuusindeksillä mitattuna tuottavuus kasvoi viidessä vuodessa yhteensä 14,3 % vuotuisen kasvun ollessa 2,7 %. Tuottajien keskimääräinen tuottavuusindeksi antaa lähes saman tuloksen: sen mukaan tuottavuus kasvaa yhteensä 14,7 %, mikä tekee 2,8 % vuodessa. Skaalatehokkuuden paraneminen havaitaan merkittävimmäksi tuottavuuskasvun lähteeksi. Skaalatehokkuus paranee aggregoidusti mitattuna 1,6 % vuodessa ja tiloilla keskimäärin 2,1 % vuodessa. Teknisen tehokkuuden koheneminen on toinen tuottavuuskasvua edistävä tekijä tutkimusjaksolla. Molemmilla mittaustavoilla nousu on keskimäärin 1,4 % vuodessa. Allokatiivinen tehokkuus laskee hieman: aggregoidusti mitattuna 0,1 % ja keskimäärin 0,4 % vuodessa. Teknologinen kehitys tutkimusjaksolla on lievästi negatiivista, keskimäärin -0,1 % vuodessa. Vuosittaiset vaihtelut ovat kuitenkin voimakkaita. Hintojen muutokset eivät juuri ole vaikuttaneet tuottavuuden tasoon, sillä hintavaikutuksen vuotuiset muutokset jäävät jokaisena vuonna alle puoleen prosenttiin ja keskimääräinen vuotuinen muutos on -0,1 %. Keskeinen tuottavuuskasvua edistänyt tekijä näyttää olleen tilakoon kasvu, joka on parantanut rakenteellista tehokkuutta. Teknologisen kehityksen jääminen negatiiviseksi kuitenkin tarkoittaa, että paras havaittu tuottavuuden taso ei ole noussut lainkaan.
Resumo:
Although the first procedure in a seeing human eye using excimer laser was reported in 1988 (McDonald et al. 1989, O'Connor et al. 2006) just three studies (Kymionis et al. 2007, O'Connor et al. 2006, Rajan et al. 2004) with a follow-up over ten years had been published when this thesis was started. The present thesis aims to investigate 1) the long-term outcomes of excimer laser refractive surgery performed for myopia and/or astigmatism by photorefractive keratectomy (PRK) and laser-in situ- keratomileusis (LASIK), 2) the possible differences in postoperative outcomes and complications when moderate-to-high astigmatism is treated with PRK or LASIK, 3) the presence of irregular astigmatism that depend exclusively on the corneal epithelium, and 4) the role of corneal nerve recovery in corneal wound healing in PRK enhancement. Our results revealed that in long-term the number of eyes that achieved uncorrected visual acuity (UCVA)≤0.0 and ≤0.5 (logMAR) was higher after PRK than after LASIK. Postoperative stability was slightly better after PRK than after LASIK. In LASIK treated eyes the incidence of myopic regression was more pronounced when the intended correction was over >6.0 D and in patients aged <30 years.Yet the intended corrections in our study were higher for LASIK than for PRK eyes. No differences were found in percentages of eyes with best corrected visual acuity (BCVA) or loss of two or more lines of visual acuity between PRK and LASIK in the long-term. The postoperative long-term outcomes of PRK with two different delivery systems broad beam and scanning laser were compared and revealed no differences. Postoperative outcomes of moderate-to-high astigmatism yielded better results in terms of UCVA and less compromise or loss of two more lines of BCVA after LASIK that after PRK.Similar stability for both procedures was revealed. Vector analysis showed that LASIK outcomes tended to be more accurate than PRK outcomes, yet no statistically differences were found. Irregular astigmatism secondary to recurrent corneal erosion due to map-dot-fingerprint was successfully treated with phototherapeutic keratectomy (PTK). Preoperative videokeratographies (VK) showed irregular astigmatism. However, postoperatively, all eyes showed a regular pattern. No correlation was found between pre- and postoperative VK patterns. Postoperative outcomes of late PRK in eyes originally subjected to LASIK showed that all (7/7) eyes achieved UCVA ≤0.5 at last follow-up (range 3 — 11 months), and no eye lost lines of BCVA. Postoperatively all eyes developed and initial mild haze (0.5 — 1) into the first month. Yet, at last follow-up 5/7 eyes showed a haze of 0.5 and this was no longer evident in 2/7 eyes. Based on these results, we demonstrated that the long-term outcomes after PRK and LASIK were safe and efficient, with similar stability for both procedures. The PRK outcomes were similar when treated by broad-beam or scanning slit laser. LASIK was better than PRK to correct moderate-to-high astigmatism, yet both procedures showed a tendency of undercorrection. Irregular astigmatism was proven to be able to depend exclusively from the corneal epithelium. If this kind of astigmatism is present in the cornea and a customized PRK/LASIK correction is done based on wavefront measurements an irregular astigmatism may be produced rather than treated. Corneal sensory nerve recovery should have an important role in the modulation of the corneal wound healing and post-operative anterior stromal scarring. PRK enhancement may be an option in eyes with previous LASIK after a sufficient time interval that in at least 2 years.
Resumo:
Sanukitoid series intrusions can be found throughout the Archean Karelian Province of the Fennoscandian shield. All sanukitoids share the same controversial elemental characteristics: they have high content of incompatible elements such as K, Ba, and Sr as well as high content of the compatible elements Mg, Cr, and Ni, and high Mg#. This composition is explained by an enriched mantle wedge origin in a Neoarchean subduction setting. This study concentrates on sanukitoid intrusions and tonalite-trondhjemite-granodiorite series (TTGs) from Finnish part of the Karelian Province. The collected rock samples have been studied in the field and under microscope as well as for their whole-rock (including isotopes) and mineral compositions. The new data together with previously published analyses help us to better understand the petrogenesis, tectonic setting and reworking of the Archean rock units. TTGs from the Karelian Province form a voluminous series of granitoids and reworked migmatites. This study divides TTG series into two subgroups based on their elemental composition: low-HREE (heavy rare earth element) TTGs and high-HREE TTGs indicating pressure differences in their source. Sanukitoid series is a minor, divergent group of intrusions. These intrusions are variable sized, and the texture varies from even-grained to K-feldspar porphyritic. The elemental composition differentiates sanukitoids from more voluminous TTG groups, the SiO2 in sanukitoids varies to include series of gabbro, diorite, and granodiorite. U Pb age determinations from sanukitoid series show temporally limited emplacement between ~ 2745 2715 Ma after the main crust forming period in the area. Hafnium, neodymium, common lead, and oxygene isotopes indicate well homogenized characteristics. Recycled crust has made a variable, yet minor, contribution to sanukitoids, as evidenced by oxygene isotopes and inherited zircon cores. A proposed tectonic setting for the formation of the sanukitoid series is slab breakoff of oceanic lithosphere in subduction setting, with sanukitoids deriving from an enriched mantle wedge. The proposed setting explains some of the peculiar features of sanukitoids, such as their temporally limited occurrence and controversial elemental composition. Sanukitoids would occur after cessation of the regional growth of Archean crust, and they could be derived from mantle wedge previously enriched by melts and fluids from oceanic crust and sediments. A subsequent event during the Paleoproterozoic Svecofennian orogeny at ~1.9 Ga affected the appearance and microstructures of the rocks as well as caused redistribution of lead between minerals and whole rock. However, the deformation was not able to obliterate the original geochemical characteristics of these sanukitoids.
Resumo:
New chemical entities with unfavorable water solubility properties are continuously emerging in drug discovery. Without pharmaceutical manipulations inefficient concentrations of these drugs in the systemic circulation are probable. Typically, in order to be absorbed from the gastrointestinal tract, the drug has to be dissolved. Several methods have been developed to improve the dissolution of poorly soluble drugs. In this study, the applicability of different types of mesoporous (pore diameters between 2 and 50 nm) silicon- and silica-based materials as pharmaceutical carriers for poorly water soluble drugs was evaluated. Thermally oxidized and carbonized mesoporous silicon materials, ordered mesoporous silicas MCM-41 and SBA-15, and non-treated mesoporous silicon and silica gel were assessed in the experiments. The characteristic properties of these materials are the narrow pore diameters and the large surface areas up to over 900 m²/g. Loading of poorly water soluble drugs into these pores restricts their crystallization, and thus, improves drug dissolution from the materials as compared to the bulk drug molecules. In addition, the wide surface area provides possibilities for interactions between the loaded substance and the carrier particle, allowing the stabilization of the system. Ibuprofen, indomethacin and furosemide were selected as poorly soluble model drugs in this study. Their solubilities are strongly pH-dependent and the poorest (< 100 µg/ml) at low pH values. The pharmaceutical performance of the studied materials was evaluated by several methods. In this work, drug loading was performed successfully using rotavapor and fluid bed equipment in a larger scale and in a more efficient manner than with the commonly used immersion methods. It was shown that several carrier particle properties, in particular the pore diameter, affect the loading efficiency (typically ~25-40 w-%) and the release rate of the drug from the mesoporous carriers. A wide pore diameter provided easier loading and faster release of the drug. The ordering and length of the pores also affected the efficiency of the drug diffusion. However, these properties can also compensate the effects of each other. The surface treatment of porous silicon was important in stabilizing the system, as the non-treated mesoporous silicon was easily oxidized at room temperature. Different surface chemical treatments changed the hydrophilicity of the porous silicon materials and also the potential interactions between the loaded drug and the particle, which further affected the drug release properties. In all of the studies, it was demonstrated that loading into mesoporous silicon and silica materials improved the dissolution of the poorly soluble drugs as compared to the corresponding bulk compounds (e.g. after 30 min ~2-7 times more drug was dissolved depending on the materials). The release profile of the loaded substances remained similar also after 3 months of storage at 30°C/56% RH. The thermally carbonized mesoporous silicon did not compromise the Caco-2 monolayer integrity in the permeation studies and improved drug permeability was observed. The loaded mesoporous silica materials were also successfully compressed into tablets without compromising their characteristic structural and drug releasing properties. The results of this research indicated that mesoporous silicon/silica-based materials are promising materials to improve the dissolution of poorly water soluble drugs. Their feasibility in pharmaceutical laboratory scale processes was also confirmed in this thesis.
Resumo:
Syövän diagnostiikassa ja hoidossa nanopartikkelit voivat toimia kuljetinaineina lääke- ja diagnostisille aineille tai nukleiinihappojaksoille. Kantaja-aineeseen voidaan liittää kohdennusmolekyylejä partikkelien passiivista tai aktiivista kohdennusta varten tai radioleima kuvantamista tai radioterapiaa varten. Kantaja-aineiden avulla voidaan parantaa lääkeaineen fysikaalis-kemiallisia ominaisuuksia ja biologista hyötyosuutta, vähentää systeemisiä sivuvaikutuksia, pidentää lääkeaineen puoliintumisaikaa ja siten harventaa annosteluväliä, sekä parantaa lääkeaineen pääsyä kohdekudokseen. Näin voidaan parantaa kemo- ja radioterapian tehoa ja hoidon onnistumisen todennäköisyyttä. Kirjallisuuskatsauksessa perehdytään nanokantajien rooliin syövän hoidossa. Vuosikymmeniä jatkuneesta tutkimuksesta huolimatta vain kaksi (Eurooppa) tai kolme (Yhdysvallat) nanopartikkeliformulaatiota on hyväksytty markkinoille syövän hoidossa. Ongelmina ovat riittämätön hakeutuminen kohdekudokseen, immunogeenisyys ja nanopartikkelien labiilius. Kokeellisessa osassa tutkitaan in vitro ja hiirillä in vivo 99mTc-leimattujen, PEG-verhoiltujen biotiiniliposomien kaksivaiheista kohdennusta ihmisen munasarjan adenokarsinoomasoluihin. Kohdentamiseen käytetään biotinyloitua setuksimabi-(Erbitux®) vasta-ainetta, joka sitoutuu solujen yli-ilmentämiin EGF-reseptoreihin. Kaksivaiheista kohdennusta verrataan suoraan ja/tai passiiviseen kohdennukseen. Tehokkaampien kuvantamismenetelmien kehitys on vauhdittanut kohdennettujen nanopartikkelien tutkimusta. Isotooppikuvantamista käyttäen pystytään seuraamaan radioleiman jakautumista elimistössä ja kuvantamaan solutasolla tapahtuvia ilmiöitä. Kirjallisuuskatsauksessa perehdytään SPECT- ja PET-kuvantamiseen syövän hoidossa, sekä niiden hyödyntämiseen lääkekehityksessä nanopartikkelien kuvantamisessa. Kyseiset kuvantamismenetelmät erottuvat muista menetelmistä korkean erotuskyvyn, herkkyyden ja helppokäyttöisyyden suhteen. Kokeellisessa osassa 99mTc-leimattujen liposomien distribuutiota hiirissä tutkittiin SPECT-CT-laitteen avulla. Aktiivisuus kasvaimessa, pernassa ja maksassa kvantifioitiin InVivoScope-ohjelman ja gammalaskijan avulla. Tuloksia verrattiin keskenään. In vitro-kokeessa saavutettiin kaksivaiheisella kohdennuksella 2,7- 3,5-kertainen (solulinjasta riippuen) hakeutuminen soluihin kontrolliliposomeihin verrattuna. Kuitenkin suora kohdennus toimi kaksivaiheista kohdennusta paremmin in vitro. In vivo –kokeissa liposomit jakautuivat kasvaimeen tehokkaammin i.p.-annosteltuna kuin i.v.-annosteltuna. Kaksivaiheisella kohdennuksella saavutettiin 1,24-kertainen jakautuminen kasvaimeen (% ID/g kudosta) passiivisesti kohdennettuihin liposomeihin verrattuna. %ID/elin oli kohdennetuilla liposomeilla 5,9 % ja passiivisesti kohdennetuilla 5,4%. Todellinen ero oli siis pieni. InVivoScope:n ja gammalaskijan tulokset eivät korreloineet keskenään. Lisätutkimuksia ja menetelmän optimointia vaaditaan liposomien kohdennuksessa kasvaimeen.