19 resultados para newborn screening
Resumo:
This thesis describes current and past n-in-one methods and presents three early experimental studies using mass spectrometry and the triple quadrupole instrument on the application of n-in-one in drug discovery. N-in-one strategy pools and mix samples in drug discovery prior to measurement or analysis. This allows the most promising compounds to be rapidly identified and then analysed. Nowadays properties of drugs are characterised earlier and in parallel with pharmacological efficacy. Studies presented here use in vitro methods as caco-2 cells and immobilized artificial membrane chromatography for drug absorption and lipophilicity measurements. The high sensitivity and selectivity of liquid chromatography mass spectrometry are especially important for new analytical methods using n-in-one. In the first study, the fragmentation patterns of ten nitrophenoxy benzoate compounds, serial homology, were characterised and the presence of the compounds was determined in a combinatorial library. The influence of one or two nitro substituents and the alkyl chain length of methyl to pentyl on collision-induced fragmentation was studied, and interesting structurefragmentation relationships were detected. Two nitro group compounds increased fragmentation compared to one nitro group, whereas less fragmentation was noted in molecules with a longer alkyl chain. The most abundant product ions were nitrophenoxy ions, which were also tested in the precursor ion screening of the combinatorial library. In the second study, the immobilized artificial membrane chromatographic method was transferred from ultraviolet detection to mass spectrometric analysis and a new method was developed. Mass spectra were scanned and the chromatographic retention of compounds was analysed using extract ion chromatograms. When changing detectors and buffers and including n-in-one in the method, the results showed good correlation. Finally, the results demonstrated that mass spectrometric detection with gradient elution can provide a rapid and convenient n-in-one method for ranking the lipophilic properties of several structurally diverse compounds simultaneously. In the final study, a new method was developed for caco-2 samples. Compounds were separated by liquid chromatography and quantified by selected reaction monitoring using mass spectrometry. This method was used for caco-2 samples, where absorption of ten chemically and physiologically different compounds was screened using both single and nin- one approaches. These three studies used mass spectrometry for compound identification, method transfer and quantitation in the area of mixture analysis. Different mass spectrometric scanning modes for the triple quadrupole instrument were used in each method. Early drug discovery with n-in-one is area where mass spectrometric analysis, its possibilities and proper use, is especially important.
Resumo:
We demonstrate how endogenous information acquisition in credit markets creates lending cycles when competing banks undertake their screening decisions in an uncoordinated way, thereby highlighting the role of intertemporal screening externalities induced by lending market competition as a structural source of instability. We show that uncoordinated screening behavior of competing banks may be not only the source of an important financial multiplier, but also an independent source of fluctuations inducing business cycles. The screening cycle mechanism is robust to generalizations along many dimensions such as the lending market structure, the lending rate determination and the imperfections in the screening technology.
Resumo:
Drug induced liver injury is one of the frequent reasons for the drug removal from the market. During the recent years there has been a pressure to develop more cost efficient, faster and easier ways to investigate drug-induced toxicity in order to recognize hepatotoxic drugs in the earlier phases of drug development. High Content Screening (HCS) instrument is an automated microscope equipped with image analysis software. It makes the image analysis faster and decreases the risk for an error caused by a person by analyzing the images always in the same way. Because the amount of drug and time needed in the analysis are smaller and multiple parameters can be analyzed from the same cells, the method should be more sensitive, effective and cheaper than the conventional assays in cytotoxicity testing. Liver cells are rich in mitochondria and many drugs target their toxicity to hepatocyte mitochondria. Mitochondria produce the majority of the ATP in the cell through oxidative phosphorylation. They maintain biochemical homeostasis in the cell and participate in cell death. Mitochondria is divided into two compartments by inner and outer mitochondrial membranes. The oxidative phosphorylation happens in the inner mitochondrial membrane. A part of the respiratory chain, a protein called cytochrome c, activates caspase cascades when released. This leads to apoptosis. The aim of this study was to implement, optimize and compare mitochondrial toxicity HCS assays in live cells and fixed cells in two cellular models: human HepG2 hepatoma cell line and rat primary hepatocytes. Three different hepato- and mitochondriatoxic drugs (staurosporine, rotenone and tolcapone) were used. Cells were treated with the drugs, incubated with the fluorescent probes and then the images were analyzed using Cellomics ArrayScan VTI reader. Finally the results obtained after optimizing methods were compared to each other and to the results of the conventional cytotoxicity assays, ATP and LDH measurements. After optimization the live cell method and rat primary hepatocytes were selected to be used in the experiments. Staurosporine was the most toxic of the three drugs and caused most damage to the cells most quickly. Rotenone was not that toxic, but the results were more reproducible and thus it would serve as a good positive control in the screening. Tolcapone was the least toxic. So far the conventional analysis of cytotoxicity worked better than the HCS methods. More optimization needs to be done to get the HCS method more sensitive. This was not possible in this study due to time limit.
Resumo:
"In rats, sucking milk reduces anxiety and promotes non-rapid eye movement (NREM) sleep, and in calves it induces resting but the effect on sleep is unknown. Here, we investigated how calves' sleep was affected by colostrum feeding methods. Forty-one calves were blocked by birth date and randomly allotted within blocks to the experimental treatments. Calves were housed for four days either with their dam (DAM) or individually with warm colostrum feeding (2 L four times a day) from either a teat bucket (TEAT) or an open bucket (BUCKET). DAM calves suckled their dam freely. Calves' sleeping and sucking behaviour was filmed continuously for 48 h at the ages of two and three days. Behavioural sleep (BS) was defined as calves resting at least 30 s with their head still and raised (non-rapid eye movement) or with their head against their body or the ground (rapid eye movement, REM). Latency from the end of colostrum feeding to the start of BS was recorded. We compared behaviour of TEAT calves with that of DAM and BUCKET calves using mixed models. Milk meal duration was significantly longer for TEAT calves than for BUCKET calves (mean +/- S.E.M.; 8.3 +/- 0.6 min vs. 5.2 +/- 0.6 min), but equal to that of DAM calves. We found no effect of feeding method on the duration of daily BS (12 h 59 min I h 38 min) but we found a tendency for the daily amount of NREM sleep; BUCKET calves had less NREM sleep per day than TEAT calves (6 h 18 min vs. 7 h 48 min, S.E.M. = 45 min) and also longer latencies from milk ingestion to BS (21.9 +/- 2.0 min vs. 16.2 +/- 2.0 min). DAM calves slept longer bouts than TEAT calves (10.8 +/- 1.0 min vs. 8.3 +/- 1.0 min) and less often (78 +/- 4 vs. 92 +/- 4). Sucking colostrum from a teat bucket compared with drinking from an open"