23 resultados para intraocular pressure
Resumo:
X-ray Raman scattering and x-ray emission spectroscopies were used to study the electronic properties and phase transitions in several condensed matter systems. The experimental work, carried out at the European Synchrotron Radiation Facility, was complemented by theoretical calculations of the x-ray spectra and of the electronic structure. The electronic structure of MgB2 at the Fermi level is dominated by the boron σ and π bands. The high density of states provided by these bands is the key feature of the electronic structure contributing to the high critical temperature of superconductivity in MgB2. The electronic structure of MgB2 can be modified by atomic substitutions, which introduce extra electrons or holes into the bands. X ray Raman scattering was used to probe the interesting σ and π band hole states in pure and aluminum substituted MgB2. A method for determining the final state density of electron states from experimental x-ray Raman scattering spectra was examined and applied to the experimental data on both pure MgB2 and on Mg(0.83)Al(0.17)B2. The extracted final state density of electron states for the pure and aluminum substituted samples revealed clear substitution induced changes in the σ and π bands. The experimental work was supported by theoretical calculations of the electronic structure and x-ray Raman spectra. X-ray emission at the metal Kβ line was applied to the studies of pressure and temperature induced spin state transitions in transition metal oxides. The experimental studies were complemented by cluster multiplet calculations of the electronic structure and emission spectra. In LaCoO3 evidence for the appearance of an intermediate spin state was found and the presence of a pressure induced spin transition was confirmed. Pressure induced changes in the electronic structure of transition metal monoxides were studied experimentally and were analyzed using the cluster multiplet approach. The effects of hybridization, bandwidth and crystal field splitting in stabilizing the high pressure spin state were discussed. Emission spectroscopy at the Kβ line was also applied to FeCO3 and a pressure induced iron spin state transition was discovered.
Resumo:
Linear optimization model was used to calculate seven wood procurement scenarios for years 1990, 2000 and 2010. Productivity and cost functions for seven cutting, five terrain transport, three long distance transport and various work supervision and scaling methods were calculated from available work study reports. All method's base on Nordic cut to length system. Finland was divided in three parts for description of harvesting conditions. Twenty imaginary wood processing points and their wood procurement areas were created for these areas. The procurement systems, which consist of the harvesting conditions and work productivity functions, were described as a simulation model. In the LP-model the wood procurement system has to fulfil the volume and wood assortment requirements of processing points by minimizing the procurement cost. The model consists of 862 variables and 560 restrictions. Results show that it is economical to increase the mechanical work in harvesting. Cost increment alternatives effect only little on profitability of manual work. The areas of later thinnings and seed tree- and shelter wood cuttings increase on cost of first thinnings. In mechanized work one method, 10-tonne one grip harvester and forwarder, is gaining advantage among other methods. Working hours of forwarder are decreasing opposite to the harvester. There is only little need to increase the number of harvesters and trucks or their drivers from today's level. Quite large fluctuations in level of procurement and cost can be handled by constant number of machines, by alternating the number of season workers and by driving machines in two shifts. It is possible, if some environmental problems of large scale summer time harvesting can be solved.
Resumo:
Hypertension is one of the major risk factors for cardiovascular morbidity. The advantages of antihypertensive therapy have been clearly demonstrated, but only about 30% of hypertensive patients have their blood pressure (BP) controlled by such treatment. One of the reasons for this poor BP control may lie in the difficulty in predicting BP response to antihypertensive treatment. The average BP reduction achieved is similar for each drug in the main classes of antihypertensive agents, but there is a marked individual variation in BP responses to any given drug. The purpose of the present study was to examine BP response to four different antihypertensive monotherapies with regard to demographic characteristics, laboratory test results and common genetic polymorphisms. The subjects of the present study are participants in the pharmacogenetic GENRES Study. A total of 208 subjects completed the whole study protocol including four drug treatment periods of four weeks, separated by four-week placebo periods. The study drugs were amlodipine, bisoprolol, hydrochlorothiazide and losartan. Both office (OBP) and 24-hour ambulatory blood pressure (ABP) measurements were carried out. BP response to study drugs were related to basic clinical characteristics, pretreatment laboratory test results and common polymorphisms in genes coding for components of the renin-angiotensin system, alpha-adducin (ADD1), beta1-adrenergic receptor (ADRB1) and beta2-adrenergic receptor (ADRB2). Age was positively correlated with BP responses to amlodipine and with OBP and systolic ABP responses to hydrochlorothiazide, while body mass index was negatively correlated with ABP responses to amlodipine. Of the laboratory test results, plasma renin activity (PRA) correlated positively with BP responses to losartan, with ABP responses to bisoprolol, and negatively with ABP responses to hydrochlorothiazide. Uniquely to this study, it was found that serum total calcium level was negatively correlated with BP responses to amlodipine, whilst serum total cholesterol level was negatively correlated with ABP responses to amlodipine. There were no significant associations of angiotensin II type I receptor 1166A/C, angiotensin converting enzyme I/D, angiotensinogen Met235Thr, ADD1 Gly460Trp, ADRB1 Ser49Gly and Gly389Arg and ADRB2 Arg16Gly and Gln27Glu polymorphisms with BP responses to the study drugs. In conclusion, this study confirmed the relationship between pretreatment PRA levels and response to three classes of antihypertensive drugs. This study is the first to note a significant inverse relation between serum calcium level and responsiveness to a calcium channel blocker. However, this study could not replicate the observations that common polymorphisms in angiotensin II type I receptor, angiotensin converting enzyme, angiotensinogen, ADD1, ADRB1, or ADRB2 genes can predict BP response to antihypertensive drugs.
Resumo:
This study is focused on the development and evaluation of ion mobility instrumentation with various atmospheric pressure ionization techniques and includes the following work. First, a high-resolution drift tube ion mobility spectrometer (IMS), coupled with a commercial triple quadrupole mass spectrometer (MS), was developed. This drift tube IMS is compatible with the front-end of commercial Sciex mass spectrometers (e.g., Sciex API-300, 365, and 3000) and also allows easy (only minor modifications are needed) installation between the original atmospheric pressure ion source and the triple quadrupole mass spectrometer. Performance haracteristics (e.g.,resolving power, detection limit, transmission efficiency of ions) of this IMS-MS instrument were evaluated. Development of the IMS-MS instrument also led to a study where a proposal was made that tetraalkylammonium ions can be used as chemical standards for ESI-IMS. Second, the same drift tube design was also used to build a standalone ion mobility spectrometer equipped with a Faraday plate detector. For this highresolution (resolving power about 100 shown) IMS device, a multi-ion source platform was built, which allows the use of a range of atmospheric pressure ionization methods, such as: corona discharge chemical ionization (CD-APCI), atmospheric pressure photoionization (APPI), and radioactive atmospheric pressure chemical ionization (R-APCI). The multi-ion source platform provides easy switching between ionization methods and both positive and negative ionization modes can be used. Third, a simple desorpion/ionization on silicon (DIOS) ion source set-up for use with the developed IMS and IMS-MS instruments was built and its operation demonstrated. Fourth, a prototype of a commercial aspiration-type ion mobility spectrometer was mounted in front of a commercial triple quadrupole mass spectrometer. The set-up, which is simple, easy to install, and requires no major modifications to the MS, provides the possibility of gathering fundamental information about aspiration mobility spectrometry.