47 resultados para Visual magnitudes measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paradigm of computational vision hypothesizes that any visual function -- such as the recognition of your grandparent -- can be replicated by computational processing of the visual input. What are these computations that the brain performs? What should or could they be? Working on the latter question, this dissertation takes the statistical approach, where the suitable computations are attempted to be learned from the natural visual data itself. In particular, we empirically study the computational processing that emerges from the statistical properties of the visual world and the constraints and objectives specified for the learning process. This thesis consists of an introduction and 7 peer-reviewed publications, where the purpose of the introduction is to illustrate the area of study to a reader who is not familiar with computational vision research. In the scope of the introduction, we will briefly overview the primary challenges to visual processing, as well as recall some of the current opinions on visual processing in the early visual systems of animals. Next, we describe the methodology we have used in our research, and discuss the presented results. We have included some additional remarks, speculations and conclusions to this discussion that were not featured in the original publications. We present the following results in the publications of this thesis. First, we empirically demonstrate that luminance and contrast are strongly dependent in natural images, contradicting previous theories suggesting that luminance and contrast were processed separately in natural systems due to their independence in the visual data. Second, we show that simple cell -like receptive fields of the primary visual cortex can be learned in the nonlinear contrast domain by maximization of independence. Further, we provide first-time reports of the emergence of conjunctive (corner-detecting) and subtractive (opponent orientation) processing due to nonlinear projection pursuit with simple objective functions related to sparseness and response energy optimization. Then, we show that attempting to extract independent components of nonlinear histogram statistics of a biologically plausible representation leads to projection directions that appear to differentiate between visual contexts. Such processing might be applicable for priming, \ie the selection and tuning of later visual processing. We continue by showing that a different kind of thresholded low-frequency priming can be learned and used to make object detection faster with little loss in accuracy. Finally, we show that in a computational object detection setting, nonlinearly gain-controlled visual features of medium complexity can be acquired sequentially as images are encountered and discarded. We present two online algorithms to perform this feature selection, and propose the idea that for artificial systems, some processing mechanisms could be selectable from the environment without optimizing the mechanisms themselves. In summary, this thesis explores learning visual processing on several levels. The learning can be understood as interplay of input data, model structures, learning objectives, and estimation algorithms. The presented work adds to the growing body of evidence showing that statistical methods can be used to acquire intuitively meaningful visual processing mechanisms. The work also presents some predictions and ideas regarding biological visual processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The overall aim of this dissertation was to study the public's preferences for forest regeneration fellings and field afforestations, as well as to find out the relations of these preferences to landscape management instructions, to ecological healthiness, and to the contemporary theories for predicting landscape preferences. This dissertation includes four case studies in Finland, each based on the visualization of management options and surveys. Guidelines for improving the visual quality of forest regeneration and field afforestation are given based on the case studies. The results show that forest regeneration can be connected to positive images and memories when the regeneration area is small and some time has passed since the felling. Preferences may not depend only on the management alternative itself but also on the viewing distance, viewing point, and the scene in which the management options are implemented. The current Finnish forest landscape management guidelines as well as the ecological healthiness of the studied options are to a large extent compatible with the public's preferences. However, there are some discrepancies. For example, the landscape management instructions as well as ecological hypotheses suggest that the retention trees need to be left in groups, whereas people usually prefer individually located retention trees to those trees in groups. Information and psycho-evolutionary theories provide some possible explanations for people's preferences for forest regeneration and field afforestation, but the results cannot be consistently explained by these theories. The preferences of the different stakeholder groups were very similar. However, the preference ratings of the groups that make their living from forest - forest owners and forest professionals - slightly differed from those of the others. These results provide support for the assumptions that preferences are largely consistent at least within one nation, but that knowledge and a reference group may also influence preferences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visual pigments of different animal species must have evolved at some stage to match the prevailing light environments, since all visual functions depend on their ability to absorb available photons and transduce the event into a reliable neural signal. There is a large literature on correlation between the light environment and spectral sensitivity between different fish species. However, little work has been done on evolutionary adaptation between separated populations within species. More generally, little is known about the rate of evolutionary adaptation to changing spectral environments. The objective of this thesis is to illuminate the constraints under which the evolutionary tuning of visual pigments works as evident in: scope, tempo, available molecular routes, and signal/noise trade-offs. Aquatic environments offer Nature s own laboratories for research on visual pigment properties, as naturally occurring light environments offer an enormous range of variation in both spectral composition and intensity. The present thesis focuses on the visual pigments that serve dim-light vision in two groups of model species, teleost fishes and mysid crustaceans. The geographical emphasis is in the brackish Baltic Sea area with its well-known postglacial isolation history and its aquatic fauna of both marine and fresh-water origin. The absorbance spectrum of the (single) dim-light visual pigment were recorded by microspectrophotometry (MSP) in single rods of 26 fish species and single rhabdoms of 8 opossum shrimp populations of the genus Mysis inhabiting marine, brackish or freshwater environments. Additionally, spectral sensitivity was determined from six Mysis populations by electroretinogram (ERG) recording. The rod opsin gene was sequenced in individuals of four allopatric populations of the sand goby (Pomatoschistus minutus). Rod opsins of two other goby species were investigated as outgroups for comparison. Rod absorbance spectra of the Baltic subspecies or populations of the primarily marine species herring (Clupea harengus membras), sand goby (P. minutus), and flounder (Platichthys flesus) were long-wavelength-shifted compared to their marine populations. The spectral shifts are consistent with adaptation for improved quantum catch (QC) as well as improved signal-to-noise ratio (SNR) of vision in the Baltic light environment. Since the chromophore of the pigment was pure A1 in all cases, this has apparently been achieved by evolutionary tuning of the opsin visual pigment. By contrast, no opsin-based differences were evident between lake and sea populations of species of fresh-water origin, which can tune their pigment by varying chromophore ratios. A more detailed analysis of differences in absorbance spectra and opsin sequence between and within populations was conducted using the sand goby as model species. Four allopatric populations from the Baltic Sea (B), Swedish west coast (S), English Channel (E), and Adriatic Sea (A) were examined. Rod absorbance spectra, characterized by the wavelength of maximum absorbance (λmax), differed between populations and correlated with differences in the spectral light transmission of the respective water bodies. The greatest λmax shift as well as the greatest opsin sequence difference was between the Baltic and the Adriatic populations. The significant within-population variation of the Baltic λmax values (506-511 nm) was analyzed on the level of individuals and was shown to correlate well with opsin sequence substitutions. The sequences of individuals with λmax at shorter wavelengths were identical to that of the Swedish population, whereas those with λmax at longer wavelengths additionally had substitution F261F/Y in the sixth transmembrane helix of the protein. This substitution (Y261) was also present in the Baltic common gobies and is known to redshift spectra. The tuning mechanism of the long-wavelength type Baltic sand gobies is assumed to be the co-expression of F261 and Y261 in all rods to produce ≈ 5 nm redshift. The polymorphism of the Baltic sand goby population possibly indicates ambiguous selection pressures in the Baltic Sea. The visual pigments of all lake populations of the opossum shrimp (Mysis relicta) were red-shifted by 25 nm compared with all Baltic Sea populations. This is calculated to confer a significant advantage in both QC and SNR in many humus-rich lakes with reddish water. Since only A2 chromophore was present, the differences obviously reflect evolutionary tuning of the visual protein, the opsin. The changes have occurred within the ca. 9000 years that the lakes have been isolated from the Sea after the most recent glaciation. At present, it seems that the mechanism explaining the spectral differences between lake and sea populations is not an amino acid substitution at any other conventional tuning site, but the mechanism is yet to be found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In anisometropia, the two eyes have unequal refractive power. Anisometropia is a risk factor for amblyopia. The visual deficiencies are thought to be irreversible after the first decade of life. There is, however, accumulating evidence that neural plasticity exists also in adult brains. The aim of this study was to investigate functional outcome of excimer laser refractive surgery in adult anisometropic and visually impaired patients. Additional goal was to examine changes in the primary visual cortex (V1) using multifocal functional magnetic resonance imaging (mffMRI) after laser refractive surgery. Study I comprised of 57 anisometropic patients (anisometropia of ≥3.25 diopters) and 174 isometropic myopic subjects formed the control group. A significant improvement in best-spectacle-corrected visual acuity (BSCVA) among myopic control subjects was evident 3 months postoperatively. The improvement in BSCVA was significantly slower for anisometropic patients and the improvement appeared to persist to the end of the follow-up (24 months). In study II we found that refractive surgery may be also successfully used for iathrogenic anisometropia. In Study III we evaluated mildly visually impaired adult patients after refractive surgery. There was a statistically significant improvement in BSCVA among visually impaired patients and the difference in the mean BSCVA between visually impaired patients and isometropic myopic control subjects diminished during follow-up. Study IV was a prospective follow-up trial examining the changes in the primary visual cortex after refractive surgery. Two anisometropic patients and two isometropic myopic patients were examined with a 61-region mffMRI before refractive surgery and at three, six, nine and twelve months postoperatively. In this study, a dramatic decrease in the number of active voxels in the fovea was found among anisometropic patients. The results presented in this thesis revealed that refractive surgery may be successfully used for the treatment of anisometropic adults with both congenital and iatrogenic anisometropia and for mildly visually impaired adults. The findings in conclusion strengthen our hypothesis of plastic changes in the visual cortex of adult anisometropic and mildly visually impaired patients after refractive surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Opiod dependence is a chronic severe brain disorder associated with enormous health and social problems. The relapse back to opioid abuse is very high especially in early abstinence, but neuropsychological and neurophysiological deficits during opioid abuse or soon after cessation of opioids are scarcely investigated. Also the structural brain changes and their correlations with the length of opioid abuse or abuse onset age are not known. In this study the cognitive functions, neural basis of cognitive dysfunction, and brain structural changes was studied in opioid-dependent patients and in age and sex matched healthy controls. Materials and methods: All subjects participating in the study, 23 opioid dependents of whom, 15 were also benzodiazepine and five cannabis co-dependent and 18 healthy age and sex matched controls went through Structured Clinical Interviews (SCID) to obtain DSM-IV axis I and II diagnosis and to exclude psychiatric illness not related to opioid dependence or personality disorders. Simultaneous magnetoencephalography (MEG) and electroencephalography (EEG) measurements were done on 21 opioid-dependent individuals on the day of hospitalization for withdrawal therapy. The neural basis of auditory processing was studied and pre-attentive attention and sensory memory were investigated. During the withdrawal 15 opioid-dependent patients participated in neuropsychological tests, measuring fluid intelligence, attention and working memory, verbal and visual memory, and executive functions. Fifteen healthy subjects served as controls for the MEG-EEG measurements and neuropsychological assessment. The brain magnetic resonance imaging (MRI) was obtained from 17 patients after approximately two weeks abstinence, and from 17 controls. The areas of different brain structures and the absolute and relative volumes of cerebrum, cerebral white and gray matter, and cerebrospinal fluid (CSF) spaces were measured and the Sylvian fissure ratio (SFR) and bifrontal ratio were calculated. Also correlation between the cerebral measures and neuropsychological performance was done. Results: MEG-EEG measurements showed that compared to controls the opioid-dependent patients had delayed mismatch negativity (MMN) response to novel sounds in the EEG and P3am on the contralateral hemisphere to the stimulated ear in MEG. The equivalent current dipole (ECD) of N1m response was stronger in patients with benzodiazepine co-dependence than those without benzodiazepine co-dependence or controls. In early abstinence the opioid dependents performed poorer than the controls in tests measuring attention and working memory, executive function and fluid intelligence. Test results of the Culture Fair Intelligence Test (CFIT), testing fluid intelligence, and Paced Auditory Serial Addition Test (PASAT), measuring attention and working memory correlated positively with the days of abstinence. MRI measurements showed that the relative volume of CSF was significantly larger in opioid dependents, which could also be seen in visual analysis. Also Sylvian fissures, expressed by SFR were wider in patients, which correlated negatively with the age of opioid abuse onset. In controls the relative gray matter volume had a positive correlation with composite cognitive performance, but this correlation was not found in opioid dependents in early abstinence. Conclusions: Opioid dependents had wide Sylvian fissures and CSF spaces indicating frontotemporal atrophy. Dilatation of Sylvian fissures correlated with the abuse onset age. During early withdrawal cognitive performance of opioid dependents was impaired. While intoxicated the pre-attentive attention to novel stimulus was delayed and benzodiazepine co-dependence impaired sound detection. All these changes point to disturbances on frontotemporal areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to estimate the prevalence and distribution of reduced visual acuity, major chronic eye diseases, and subsequent need for eye care services in the Finnish adult population comprising persons aged 30 years and older. In addition, we analyzed the effect of decreased vision on functioning and need for assistance using the World Health Organization’s (WHO) International Classification of Functioning, Disability, and Health (ICF) as a framework. The study was based on the Health 2000 health examination survey, a nationally representative population-based comprehensive survey of health and functional capacity carried out in 2000 to 2001 in Finland. The study sample representing the Finnish population aged 30 years and older was drawn by a two-stage stratified cluster sampling. The Health 2000 survey included a home interview and a comprehensive health examination conducted at a nearby screening center. If the invited participants did not attend, an abridged examination was conducted at home or in an institution. Based on our finding in participants, the great majority (96%) of Finnish adults had at least moderate visual acuity (VA ≥ 0.5) with current refraction correction, if any. However, in the age group 75–84 years the prevalence decreased to 81%, and after 85 years to 46%. In the population aged 30 years and older, the prevalence of habitual visual impairment (VA ≤ 0.25) was 1.6%, and 0.5% were blind (VA < 0.1). The prevalence of visual impairment increased significantly with age (p < 0.001), and after the age of 65 years the increase was sharp. Visual impairment was equally common for both sexes (OR 1.20, 95% CI 0.82 – 1.74). Based on self-reported and/or register-based data, the estimated total prevalences of cataract, glaucoma, age-related maculopathy (ARM), and diabetic retinopathy (DR) in the study population were 10%, 5%, 4%, and 1%, respectively. The prevalence of all of these chronic eye diseases increased with age (p < 0.001). Cataract and glaucoma were more common in women than in men (OR 1.55, 95% CI 1.26 – 1.91 and OR 1.57, 95% CI 1.24 – 1.98, respectively). The most prevalent eye diseases in people with visual impairment (VA ≤ 0.25) were ARM (37%), unoperated cataract (27%), glaucoma (22%), and DR (7%). One-half (58%) of visually impaired people had had a vision examination during the past five years, and 79% had received some vision rehabilitation services, mainly in the form of spectacles (70%). Only one-third (31%) had received formal low vision rehabilitation (i.e., fitting of low vision aids, receiving patient education, training for orientation and mobility, training for activities of daily living (ADL), or consultation with a social worker). People with low vision (VA 0.1 – 0.25) were less likely to have received formal low vision rehabilitation, magnifying glasses, or other low vision aids than blind people (VA < 0.1). Furthermore, low cognitive capacity and living in an institution were associated with limited use of vision rehabilitation services. Of the visually impaired living in the community, 71% reported a need for assistance and 24% had an unmet need for assistance in everyday activities. Prevalence of ADL, instrumental activities of daily living (IADL), and mobility increased with decreasing VA (p < 0.001). Visually impaired persons (VA ≤ 0.25) were four times more likely to have ADL disabilities than those with good VA (VA ≥ 0.8) after adjustment for sociodemographic and behavioral factors and chronic conditions (OR 4.36, 95% CI 2.44 – 7.78). Limitations in IADL and measured mobility were five times as likely (OR 4.82, 95% CI 2.38 – 9.76 and OR 5.37, 95% CI 2.44 – 7.78, respectively) and self-reported mobility limitations were three times as likely (OR 3.07, 95% CI 1.67 – 9.63) as in persons with good VA. The high prevalence of age-related eye diseases and subsequent visual impairment in the fastest growing segment of the population will result in a substantial increase in the demand for eye care services in the future. Many of the visually impaired, especially older persons with decreased cognitive capacity or living in an institution, have not had a recent vision examination and lack adequate low vision rehabilitation. This highlights the need for regular evaluation of visual function in the elderly and an active dissemination of information about rehabilitation services. Decreased VA is strongly associated with functional limitations, and even a slight decrease in VA was found to be associated with limited functioning. Thus, continuous efforts are needed to identify and treat eye diseases to maintain patients’ quality of life and to alleviate the social and economic burden of serious eye diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modern unilateral surgical treatment of otosclerosis started in 1956. Simultaneous bilateral surgery has not been reported in stapes surgery and in case of bilateral otosclerosis ears are operated in two different sessions. Simultaneous surgery would give the patient the opportunity to gain advantages of bilateral hearing within one session, with less time spent in hospital and on sick leave. The mechanism for vestibular symptoms and the exact end organ affected after surgery is still unveiled. This thesis presents the results of experimental simultaneous bilateral stapes surgery, and vestibular symptoms and findings before and after unilateral stapes surgery. In addition, we explore reasons for outpatient failures in otosclerosis surgery. -- Study I examines the outcome of simultaneous bilateral surgery. Hearing was evaluated with standard pure tone and speech audiograms and vestibular apparatus with visual feedback posturography (VFP) during the one-year follow-up. Subjective symptoms and quality of life were assessed with questionnaires. In study II, reasons for outpatient failures in stapes surgery were explored. Forty-seven consecutive stapedotomies and stapedectomies performed by the same surgeon were included, and the effect of failures on hearing results were analysed. Vestibular symptoms and the end organ(s) affected after stapes surgery were investigated in studies III and IV. With video-oculography (VOG), nystagmus was measured preoperatively, and at one week, one month and 3 months postoperatively in the first phase (III). In the second phase (IV), recordings were obtained some hours postoperatively. The hearing results of the simultaneous bilateral surgery were comparable with unilateral surgeries reported. Recovery from the surgery was fast. Significant improvement in performance and quality of life was noted already month after operation in subjective evaluations. Based on these results, simultaneous bilateral surgery is a suitable approach in bilateral otosclerosis Significantly more outpatient failures occurred for medical reasons in the stapedectomy group (13%) than in the stapedotomy group (2%). Stapedotomy should be favoured if outpatient surgery is planned. However, unplanned admission did not worsen the prognosis. VOG measurements in study III did not show any specific type of nystagmus in patients having vestibular symptoms postoperatively. However, VOG measurements immediately after surgery (IV) revealed nystagmus consistent with a minor disturbance of the semicircular canals in 33% of the patients. Subjectively, half of the patients reported vestibular symptoms that were probably of diverse origin, and could have originated from both otolith and semicircular canal parts of the vestibular organ. Since vestibular symptoms and signs are mild, patients may be safely discharged some hours after stapes surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The adequacy of anesthesia has been studied since the introduction of balanced general anesthesia. Commercial monitors based on electroencephalographic (EEG) signal analysis have been available for monitoring the hypnotic component of anesthesia from the beginning of the 1990s. Monitors measuring the depth of anesthesia assess the cortical function of the brain, and have gained acceptance during surgical anesthesia with most of the anesthetic agents used. However, due to frequent artifacts, they are considered unsuitable for monitoring consciousness in intensive care patients. The assessment of analgesia is one of the cornerstones of general anesthesia. Prolonged surgical stress may lead to increased morbidity and delayed postoperative recovery. However, no validated monitoring method is currently available for evaluating analgesia during general anesthesia. Awareness during anesthesia is caused by an inadequate level of hypnosis. This rare but severe complication of general anesthesia may lead to marked emotional stress and possibly posttraumatic stress disorder. In the present series of studies, the incidence of awareness and recall during outpatient anesthesia was evaluated and compared with that of in inpatient anesthesia. A total of 1500 outpatients and 2343 inpatients underwent a structured interview. Clear intraoperative recollections were rare the incidence being 0.07% in outpatients and 0.13% in inpatients. No significant differences emerged between outpatients and inpatients. However, significantly smaller doses of sevoflurane were administered to outpatients with awareness than those without recollections (p<0.05). EEG artifacts in 16 brain-dead organ donors were evaluated during organ harvest surgery in a prospective, open, nonselective study. The source of the frontotemporal biosignals in brain-dead subjects was studied, and the resistance of bispectral index (BIS) and Entropy to the signal artifacts was compared. The hypothesis was that in brain-dead subjects, most of the biosignals recorded from the forehead would consist of artifacts. The original EEG was recorded and State Entropy (SE), Response Entropy (RE), and BIS were calculated and monitored during solid organ harvest. SE differed from zero (inactive EEG) in 28%, RE in 29%, and BIS in 68% of the total recording time (p<0.0001 for all). The median values during the operation were SE 0.0, RE 0.0, and BIS 3.0. In four of the 16 organ donors, EEG was not inactive, and unphysiologically distributed, nonreactive rhythmic theta activity was present in the original EEG signal. After the results from subjects with persistent residual EEG activity were excluded, SE, RE, and BIS differed from zero in 17%, 18%, and 62% of the recorded time, respectively (p<0.0001 for all). Due to various artifacts, the highest readings in all indices were recorded without neuromuscular blockade. The main sources of artifacts were electrocauterization, electromyography (EMG), 50-Hz artifact, handling of the donor, ballistocardiography, and electrocardiography. In a prospective, randomized study of 26 patients, the ability of Surgical Stress Index (SSI) to differentiate patients with two clinically different analgesic levels during shoulder surgery was evaluated. SSI values were lower in patients with an interscalene brachial plexus block than in patients without an additional plexus block. In all patients, anesthesia was maintained with desflurane, the concentration of which was targeted to maintain SE at 50. Increased blood pressure or heart rate (HR), movement, and coughing were considered signs of intraoperative nociception and treated with alfentanil. Photoplethysmographic waveforms were collected from the contralateral arm to the operated side, and SSI was calculated offline. Two minutes after skin incision, SSI was not increased in the brachial plexus block group and was lower (38 ± 13) than in the control group (58 ± 13, p<0.005). Among the controls, one minute prior to alfentanil administration, SSI value was higher than during periods of adequate antinociception, 59 ± 11 vs. 39 ± 12 (p<0.01). The total cumulative need for alfentanil was higher in controls (2.7 ± 1.2 mg) than in the brachial plexus block group (1.6 ± 0.5 mg, p=0.008). Tetanic stimulation to the ulnar region of the hand increased SSI significantly only among patients with a brachial plexus block not covering the site of stimulation. Prognostic value of EEG-derived indices was evaluated and compared with Transcranial Doppler Ultrasonography (TCD), serum neuron-specific enolase (NSE) and S-100B after cardiac arrest. Thirty patients resuscitated from out-of-hospital arrest and treated with induced mild hypothermia for 24 h were included. Original EEG signal was recorded, and burst suppression ratio (BSR), RE, SE, and wavelet subband entropy (WSE) were calculated. Neurological outcome during the six-month period after arrest was assessed with the Glasgow-Pittsburgh Cerebral Performance Categories (CPC). Twenty patients had a CPC of 1-2, one patient had a CPC of 3, and nine patients died (CPC 5). BSR, RE, and SE differed between good (CPC 1-2) and poor (CPC 3-5) outcome groups (p=0.011, p=0.011, p=0.008, respectively) during the first 24 h after arrest. WSE was borderline higher in the good outcome group between 24 and 48 h after arrest (p=0.050). All patients with status epilepticus died, and their WSE values were lower (p=0.022). S-100B was lower in the good outcome group upon arrival at the intensive care unit (p=0.010). After hypothermia treatment, NSE and S-100B values were lower (p=0.002 for both) in the good outcome group. The pulsatile index was also lower in the good outcome group (p=0.004). In conclusion, the incidence of awareness in outpatient anesthesia did not differ from that in inpatient anesthesia. Outpatients are not at increased risk for intraoperative awareness relative to inpatients undergoing general anesthesia. SE, RE, and BIS showed non-zero values that normally indicate cortical neuronal function, but were in these subjects mostly due to artifacts after clinical brain death diagnosis. Entropy was more resistant to artifacts than BIS. During general anesthesia and surgery, SSI values were lower in patients with interscalene brachial plexus block covering the sites of nociceptive stimuli. In detecting nociceptive stimuli, SSI performed better than HR, blood pressure, or RE. BSR, RE, and SE differed between the good and poor neurological outcome groups during the first 24 h after cardiac arrest, and they may be an aid in differentiating patients with good neurological outcomes from those with poor outcomes after out-of-hospital cardiac arrest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the applicability of visual feedback posturography (VFP) for quantification of postural control, and to characterize the horizontal angular vestibulo-ocular reflex (AVOR) by use of a novel motorized head impulse test (MHIT). Methods: In VFP, subjects standing on a platform were instructed to move their center of gravity to symmetrically placed peripheral targets as fast and accurately as possible. The active postural control movements were measured in healthy subjects (n = 23), and in patients with vestibular schwannoma (VS) before surgery (n = 49), one month (n = 17), and three months (n = 36) after surgery. In MHIT we recorded head and eye position during motorized head impulses (mean velocity of 170º/s and acceleration of 1 550º/s²) in healthy subjects (n = 22), in patients with VS before surgery (n = 38) and about four months afterwards (n = 27). The gain, asymmetry and latency in MHIT were calculated. Results: The intraclass correlation coefficient for VFP parameters during repeated tests was significant (r = 0.78-0.96; p < 0.01), although two of four VFP parameters improved slightly during five test sessions in controls. At least one VFP parameter was abnormal pre- and postoperatively in almost half the patients, and these abnormal preoperative VFP results correlated significantly with abnormal postoperative results. The mean accuracy in postural control in patients was reduced pre- and postoperatively. A significant side difference with VFP was evident in 10% of patients. In the MHIT, the normal gain was close to unity, the asymmetry in gain was within 10%, and the latency was a mean ± standard deviation 3.4 ± 6.3 milliseconds. Ipsilateral gain or asymmetry in gain was preoperatively abnormal in 71% of patients, whereas it was abnormal in every patient after surgery. Preoperative gain (mean ± 95% confidence interval) was significantly lowered to 0.83 ± 0.08 on the ipsilateral side compared to 0.98 ± 0.06 on the contralateral side. The ipsilateral postoperative mean gain of 0.53 ± 0.05 was significantly different from preoperative gain. Conclusion: The VFP is a repeatable, quantitative method to assess active postural control within individual subjects. The mean postural control in patients with VS was disturbed before and after surgery, although not severely. Side difference in postural control in the VFP was rare. The horizontal AVOR results in healthy subjects and in patients with VS, measured with MHIT, were in agreement with published data achieved using other techniques with head impulse stimuli. The MHIT is a non-invasive method which allows reliable clinical assessment of the horizontal AVOR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevalence and the causes of childhood visual impairment in Finland during the 1970s and the 1980s were investigated, with special attention to risk factors and further prevention of visual impairment in children. The primary data on children with visual impairment were obtained from the Finnish Register of Visual Impairment, one of the patient registers kept up by the National Research and Development Centre for Welfare and Health (Stakes). The data were supplemented from other registers in Stakes and from patient records of the children in Finnish central hospitals. Visual impairment had been registered in 556 children from a population of 1,138,326 children between ages 0-17, born from 1972 through 1989. The age-specific prevalence of registered visual impairment was 49/100,000 in total. Of them, 23/100,000 were blind children and 11/100,000 were children born prematurely. Boys were impaired more often and more severely than girls. Congenital malformations (52%), systemic diseases (48%), and multiple impairments (50%) were common. The main ophthalmic groups of visual impairment were retinal diseases (35%), ocular malformations (29%), and neuro-ophthalmological disorders (29%). Optic nerve atrophy was the most common diagnosis of visual impairment (22%), followed by congenital cataract (11%), retinopathy of prematurity (10%), and cerebral visual impairment (8%). Genetic factors (42%) were the most common etiologies of visual impairment, followed by prenatal (30%) and perinatal (21%) factors. The highest rates of blindness were seen in cerebral visual impairment (83%) and retinopathy of prematurity (82%). Retinopathy of prematurity had developed in the children born at a gestational age of 32 weeks or earlier. Significant risks for visual impairment were found in the association with preterm births, prenatal infections, birth asphyxia, neonatal respiratory difficulties, mechanical ventilation lasting over two weeks, and hyperbilirubinemia. A rise in blind and multi-impaired children was seen during the study period, associating with increases in the survival of preterm infants with extremely low birth weight. The incidence of visual impairment in children born prematurely was seven times higher than in children born at full term. A reliable profile of childhood visual impairment was obtained. The importance of highly qualified antenatal, neonatal, and ophthalmological care was clearly proved. The risks associated with pre- and perinatal disorders during pregnancy must be emphasized, e.g. the risks associated with maternal infections and the use of tobacco, alcohol, and drugs during pregnancy. Obvious needs for gene therapies and other new treatments for hereditary diseases were also proved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data assimilation provides an initial atmospheric state, called the analysis, for Numerical Weather Prediction (NWP). This analysis consists of pressure, temperature, wind, and humidity on a three-dimensional NWP model grid. Data assimilation blends meteorological observations with the NWP model in a statistically optimal way. The objective of this thesis is to describe methodological development carried out in order to allow data assimilation of ground-based measurements of the Global Positioning System (GPS) into the High Resolution Limited Area Model (HIRLAM) NWP system. Geodetic processing produces observations of tropospheric delay. These observations can be processed either for vertical columns at each GPS receiver station, or for the individual propagation paths of the microwave signals. These alternative processing methods result in Zenith Total Delay (ZTD) and Slant Delay (SD) observations, respectively. ZTD and SD observations are of use in the analysis of atmospheric humidity. A method is introduced for estimation of the horizontal error covariance of ZTD observations. The method makes use of observation minus model background (OmB) sequences of ZTD and conventional observations. It is demonstrated that the ZTD observation error covariance is relatively large in station separations shorter than 200 km, but non-zero covariances also appear at considerably larger station separations. The relatively low density of radiosonde observing stations limits the ability of the proposed estimation method to resolve the shortest length-scales of error covariance. SD observations are shown to contain a statistically significant signal on the asymmetry of the atmospheric humidity field. However, the asymmetric component of SD is found to be nearly always smaller than the standard deviation of the SD observation error. SD observation modelling is described in detail, and other issues relating to SD data assimilation are also discussed. These include the determination of error statistics, the tuning of observation quality control and allowing the taking into account of local observation error correlation. The experiments made show that the data assimilation system is able to retrieve the asymmetric information content of hypothetical SD observations at a single receiver station. Moreover, the impact of real SD observations on humidity analysis is comparable to that of other observing systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Earth's ecosystems are protected from the dangerous part of the solar ultraviolet (UV) radiation by stratospheric ozone, which absorbs most of the harmful UV wavelengths. Severe depletion of stratospheric ozone has been observed in the Antarctic region, and to a lesser extent in the Arctic and midlatitudes. Concern about the effects of increasing UV radiation on human beings and the natural environment has led to ground based monitoring of UV radiation. In order to achieve high-quality UV time series for scientific analyses, proper quality control (QC) and quality assurance (QA) procedures have to be followed. In this work, practices of QC and QA are developed for Brewer spectroradiometers and NILU-UV multifilter radiometers, which measure in the Arctic and Antarctic regions, respectively. These practices are applicable to other UV instruments as well. The spectral features and the effect of different factors affecting UV radiation were studied for the spectral UV time series at Sodankylä. The QA of the Finnish Meteorological Institute's (FMI) two Brewer spectroradiometers included daily maintenance, laboratory characterizations, the calculation of long-term spectral responsivity, data processing and quality assessment. New methods for the cosine correction, the temperature correction and the calculation of long-term changes of spectral responsivity were developed. Reconstructed UV irradiances were used as a QA tool for spectroradiometer data. The actual cosine correction factor was found to vary between 1.08-1.12 and 1.08-1.13. The temperature characterization showed a linear temperature dependence between the instrument's internal temperature and the photon counts per cycle. Both Brewers have participated in international spectroradiometer comparisons and have shown good stability. The differences between the Brewers and the portable reference spectroradiometer QASUME have been within 5% during 2002-2010. The features of the spectral UV radiation time series at Sodankylä were analysed for the time period 1990-2001. No statistically significant long-term changes in UV irradiances were found, and the results were strongly dependent on the time period studied. Ozone was the dominant factor affecting UV radiation during the springtime, whereas clouds played a more important role during the summertime. During this work, the Antarctic NILU-UV multifilter radiometer network was established by the Instituto Nacional de Meteorogía (INM) as a joint Spanish-Argentinian-Finnish cooperation project. As part of this work, the QC/QA practices of the network were developed. They included training of the operators, daily maintenance, regular lamp tests and solar comparisons with the travelling reference instrument. Drifts of up to 35% in the sensitivity of the channels of the NILU-UV multifilter radiometers were found during the first four years of operation. This work emphasized the importance of proper QC/QA, including regular lamp tests, for the multifilter radiometers also. The effect of the drifts were corrected by a method scaling the site NILU-UV channels to those of the travelling reference NILU-UV. After correction, the mean ratios of erythemally-weighted UV dose rates measured during solar comparisons between the reference NILU-UV and the site NILU-UVs were 1.007±0.011 and 1.012±0.012 for Ushuaia and Marambio, respectively, when the solar zenith angle varied up to 80°. Solar comparisons between the NILU-UVs and spectroradiometers showed a ±5% difference near local noon time, which can be seen as proof of successful QC/QA procedures and transfer of irradiance scales. This work also showed that UV measurements made in the Arctic and Antarctic can be comparable with each other.