22 resultados para Tests accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present challenge in drug discovery is to synthesize new compounds efficiently in minimal time. The trend is towards carefully designed and well-characterized compound libraries because fast and effective synthesis methods easily produce thousands of new compounds. The need for rapid and reliable analysis methods is increased at the same time. Quality assessment, including the identification and purity tests, is highly important since false (negative or positive) results, for instance in tests of biological activity or determination of early-ADME parameters in vitro (the pharmacokinetic study of drug absorption, distribution, metabolism, and excretion), must be avoided. This thesis summarizes the principles of classical planar chromatographic separation combined with ultraviolet (UV) and mass spectrometric (MS) detection, and introduces powerful, rapid, easy, low-cost, and alternative tools and techniques for qualitative and quantitative analysis of small drug or drug-like molecules. High performance thin-layer chromatography (HPTLC) was introduced and evaluated for fast semi-quantitative assessment of the purity of synthesis target compounds. HPTLC methods were compared with the liquid chromatography (LC) methods. Electrospray ionization mass spectrometry (ESI MS) and atmospheric pressure matrix-assisted laser desorption/ionization MS (AP MALDI MS) were used to identify and confirm the product zones on the plate. AP MALDI MS was rapid, and easy to carry out directly on the plate without scraping. The PLC method was used to isolate target compounds from crude synthesized products and purify them for bioactivity and preliminary ADME tests. Ultra-thin-layer chromatography (UTLC) with AP MALDI MS and desorption electrospray ionization mass spectrometry (DESI MS) was introduced and studied for the first time. Because of the thinner adsorbent layer, the monolithic UTLC plate provided 10 100 times better sensitivity in MALDI analysis than did HPTLC plates. The limits of detection (LODs) down to low picomole range were demonstrated for UTLC AP MALDI and UTLC DESI MS. In a comparison of AP and vacuum MALDI MS detection for UTLC plates, desorption from the irregular surface of the plates with the combination of an external AP MALDI ion source and an ion trap instrument provided clearly less variation in mass accuracy than the vacuum MALDI time-of-flight (TOF) instrument. The performance of the two-dimensional (2D) UTLC separation with AP MALDI MS method was studied for the first time. The influence of the urine matrix on the separation and the repeatability was evaluated with benzodiazepines as model substances in human urine. The applicability of 2D UTLC AP MALDI MS was demonstrated in the detection of metabolites in an authentic urine sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Helicobacter pylori infection, although the prevalence is declining in Western world, is still responsible for several clinically important diseases. None of the diagnostic tests is perfect and in this study, the performance of three stool antigen tests was assessed. In areas of high H. pylori prevalence, the definition of patients with the greatest benefit from eradication therapy may be a problem; the role of duodenal gastric metaplasia in categorizing patients at risk for duodenal ulcer was evaluated in this respect. Whether persistent chronic inflammation and elevated H. pylori antibodies after successful eradication are associated with each other or with atrophic gastritis, a long term sequelae of H. pylori infection, were also studied. Patients and methods: The three stool antigen tests were assessed in pre- and post-eradication settings among 364 subjects in two studies as compared to the rapid urease test (RUT), histology, culture, the 13C-urea breath test (UBT) and enzyme immunoassay (EIA) based H. pylori serology. The association between duodenal gastric metaplasia with duodenal ulcer was evaluated in a retrospective study including 1054 patients gastroscopied due to clinical indications and 154 patients previously operated for duodenal ulcer. The extent of duodenal gastric metaplasia was assessed from histological specimens in different patient groups formed on the basis of gastroscopy findings and H. pylori infection. Chronic gastric inflammation (108 patients) and H. pylori antibodies and serum markers for atrophy (77 patients) were assessed in patients earlier treated for H. pylori. Results: Of the stool antigen tests studied, the monoclonal antibody-based EIA-test showed the highest sensitivity and specificity both in the pre-treatment setting (96.9% and 95.9%) and after therapy (96.9% and 97.8%). The polyclonal stool antigen test and the in-office test had at baseline a sensitivity of 91% and 94%, and a specificity of 96% and 89%, respectively and in a post-treatment setting, a sensitivity of 78% and 91%, and a specificity of 97%, respectively. Duodenal gastric metaplasia was strongly associated with H. pylori positive duodenal ulcer (odds ratio 42). Although common still five years after eradication, persistent chronic gastric inflammation (21%) and elevated H. pylori antibodies (33%) were neither associated with each other nor with atrophic gastritis. Conclusions: Current H. pylori infection can feasibly be diagnosed by a monoclonal antibody-based EIA test with the accuracy comparable to that of reference methods. The performance of the polyclonal test as compared to the monoclonal test was inferior especially in the post-treatment setting. The in-office test had a low specificity for primary diagnosis and hence positive test results should probably be confirmed with another test before eradication therapy is prescribed. The presence of widespread duodenal gastric metaplasia showed promising results in detecting patients who should be treated for H. pylori due to an increased risk of duodenal ulcer. If serology is used later on in patients with earlier successfully treated for H. pylori, it should be taken into account that H. pylori antibodies may persist elevated for years for unknown reason. However, this phenomenon was not found to be associated with persistent chronic inflammation or atrophic changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Helicobacter pylorin (helikobakteeri) tartunta saadaan yleensä lapsena ja tauti jää tavallisesti pysyväksi ilman täsmähoitoa. Onnistunut hoito parantaa pysyvästi helikobakteerista aiheutuvan mahan haavataudin ja näyttää ehkäisevän mahalaukun pahanlaatuisten muutosten kehittymistä. Aloitimme Vammalassa terveyskeskuksessa toteutetun kansainvälisesti ainutlaatuisen väestöpohjaisen helikobakteeritulehduksen seulonta- ja hoito-ohjelman pilottitutkimuksella 1994. 1996 kaikki 15-40-vuotiaat ja 1997-2000 15- ja 45-vuotiaat vammalalaiset kutsuttiin verinäyteseulontaan. Yhteensä 4626 henkilöä (75% kutsutuista) osallistui seulontaan. Vasta-ainepositiivisille tarjottiin helikobakteeritulehduksen lopettava lääkekuuri. Toiminnan seurauksena helikobakteeritulehduksen esiintyvyyden laskettiin vähentyneen 12%:sta 4%:iin 15-40-vuotiaiden ikäryhmässä. Tutkimme myös helikobakteerivasta-ainepositiivisten ja -negatiivisten eroja sekä helikobakteeritulehduksen riskitekijöitä kyselytutkimuksella. Lapsuudenkodin asumisahtauden, äidin matalan koulutusasteen, tupakoinnin, alkoholinkäytön, huonojen asunto-olojen ja ylävatsavaivoista johtuvien sairauslomien todettiin liittyvän helikobakteeritulehdukseen monimuuttuja-analyysissa. Tutkimme seulontaohjelmassa käyttämiemme IgG- ja IgA-luokan helikobakteeri-vasta-ainetestien luotettavuutta eri ikäryhmissä ottaen huomioon atrofisen gastriitin esiintyvyyden. 561 kliinisin perustein gastroskopoidun potilaan aineistossa IgG-testi osoittautui erittäin herkäksi kaikissa ikäryhmissä (99%). Tarkkuus oli myös vanhemmissa ikäryhmissä hyvä (97-93%), kun atrofista gastriittia sairastavat suljettiin pois. IgA- ja CagA-helikobakteerivasta-aineiden on todettu liittyvän lisääntyneeseen mahahaava- ja mahasyöpäriskiin. Analysoimme 560 henkilön pariseeruminäytteet, jotka oli otettu kahden vuosikymmenen välein, ja totesimme, että IgA-vasta-aineiden esiintyvyyden lisääntyyminen iän myötä johtuu paitsi syntymäajankohdasta ja uusista infektioista myös IgA-vasta-ainetasojen kohoamisesta helikobakteeritulehduksen aikana. Selvitimme myös CagA-vasta-ainetasojen muuttumista analysoimalla seeruminäytteet, jotka oli otettu kahden vuosikymmenen välein. Totesimme, että samanaikaisesti kun helikobakteerin esiintyvyys väestössä on alentunut, erityisesti CagA-positiiviset infektiot ovat vähentyneet. Tutkimuksemme osoittaa, että Suomessa terveyskeskuksen yhteydessä voidaan toteuttaa näin laajamittainen seulonta- ja hoito-ohjelma, johon suomalaiset osallistuvat aktiivisesti. Nähtäväksi jää, kuinka paljon ohjelma kykeni vähentämään helikobakteeritulehdukseen liittyviä myöhäisseuraamuksia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The type A lantibiotic nisin produced by several Lactococcus lactis strains, and one Streptococcus uberis strainis a small antimicrobial peptide that inhibits the growth of a wide range of gram-positive bacteria, such as Bacillus, Clostridium, Listeria and Staphylococcus species. It is nontoxic to humans and used as a food preservative (E234) in more than 50 countries including the EU, the USA, and China. National legislations concerning maximum addition levels of nisin in different foods vary greatly. Therefore, there is a demand for non-laborious and sensitive methods to identify and quantify nisin reliably from different food matrices. The horizontal inhibition assay, based on the inhibitory effect of nisin to Micrococcus luteus is the base for most quantification methods developed so far. However, the sensitivity and accuracy of the agar diffusion method is affected by several parameters. Immunological tests have also been described. Taken into account the sensitivity of immunological methods to interfering substances within sample matrices, and possible cross-reactivities with lantibiotics structurally close to nisin, their usefulness for nisin detection from food samples remains limited. The proteins responsible for nisin biosynthesis, and producer self-immunity are encoded by genes arranged into two inducible operons, nisA/Z/QBTCIPRK and nisFEG, which also contain internal, constitutive promoters PnisI and PnisR. The transmembrane histidine kinase NisK and the response regulator NisR form a two-component signal transduction system, in which NisK autophosphorylates after exposure to extra cellular nisin, and subsequently transfers the phosphate to NisR. The phosphorylated NisR then relays the signal downstream by binding to two regulated promoters in the nisin gene cluster, i.e the nisA/Z/Qand the nisF promoters, thus activating transcription of the structural gene nisA/Z/Q and the downstream genes nisBTCIPRK from the nisA/Z/Q promoter, and the genes nisFEG from the nisF promoter. In this work two novel and highly sensitive nisin bioassays were developed. Both of these quantification methods were based on NisRK mediated, nisin induced Green Fluorescent Protein (GFP) fluorescence. The suitabilities of these assays for quantifica¬tion of nisin from food samples were evaluated in several food matrices. These bioassays had nisin sensitivities in the nanogram or picogram levels. In addition, shelf life of nisin in cooked sausages and retainment of the induction activity of nisin in intestinal chyme (intestinal content) was assessed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ALICE (A Large Ion Collider Experiment) is an experiment at CERN (European Organization for Nuclear Research), where a heavy-ion detector is dedicated to exploit the unique physics potential of nucleus-nucleus interactions at LHC (Large Hadron Collider) energies. In a part of that project, 716 so-called type V4 modules were assembles in Detector Laboratory of Helsinki Institute of Physics during the years 2004 - 2006. Altogether over a million detector strips has made this project the most massive particle detector project in the science history of Finland. One ALICE SSD module consists of a double-sided silicon sensor, two hybrids containing 12 HAL25 front end readout chips and some passive components, such has resistors and capacitors. The components are connected together by TAB (Tape Automated Bonding) microcables. The components of the modules were tested in every assembly phase with comparable electrical tests to ensure the reliable functioning of the detectors and to plot the possible problems. The components were accepted or rejected by the limits confirmed by ALICE collaboration. This study is concentrating on the test results of framed chips, hybrids and modules. The total yield of the framed chips is 90.8%, hybrids 96.1% and modules 86.2%. The individual test results have been investigated in the light of the known error sources that appeared during the project. After solving the problems appearing during the learning-curve of the project, the material problems, such as defected chip cables and sensors, seemed to induce the most of the assembly rejections. The problems were typically seen in tests as too many individual channel failures. Instead, the bonding failures rarely caused the rejections of any component. One sensor type among three different sensor manufacturers has proven to have lower quality than the others. The sensors of this manufacturer are very noisy and their depletion voltage are usually outside of the specification given to the manufacturers. Reaching 95% assembling yield during the module production demonstrates that the assembly process has been highly successful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary biliary cirrhosis (PBC) is caused by an autoimmune inflammation of the small bile ducts. It results to destruction of bile ducts, accumulation of the bile in the liver, and cirrhosis. The prevalence and incidence of PBC is increasing in the Western world. The prevalence is highest in the USA (402 per million) and incidence in Scotland (49/million/year). Our aim was to assess the epidemiology of PBC in Finland. Patients for the epidemiological study were searched from the hospital discharge records from year 1988 to 1999.The prevalence rose from 103 to 180/million from 1988 to 1999, an annual increase of 5.1%. The incidence rose from 12 to 17 /million/year, an annual increase of 3.5%. The age at death increased markedly from 65 to 76 years. The risk of liver related deaths diminished over time. The treatment of PBC is based on Ursodeoxycholic acid (UDCA). During 20 years 50% of patients end up with cirrhosis. Our treatment option was to combine budesonide, a potent corticosteroid with a high first pass metabolism in the liver, to UDCA and evaluate the liver effects and systemic effects such as bone mass density (BMD) changes. Our aim was to find out if combination of laboratory tests would serve as a surrogate marker for PBC and help reducing the need for liver biopsy. Non-cirrhotic PBC patients were randomized to receive budesonide 6 mg/day combined to UDCA 15 mg /kg/day or UDCA alone for three years. The combination therapy with UDCA and budesonide was effective: stage improved 22%, fibrosis 25%, and inflammation 32%. In the UDCA group the changes were: 20% deterioriation in stage and 70% in fibrosis, but a 10% improvement in inflammation. BMD in femoral neck decreased by 3.6% in the combination group and by 1.9% in the UDCA group. The reductions in lumbar spine were 2.8% and 0.7%. Pharmacokinetics did not differ between the stages of PBC. HA, PIIINP, bile acids, and AST were significantly different within stages I-III and could differentiate the mild fibrosis (F0F1) from the moderate (F2F3). The combination of these individual markers (PBC-score) further improved the accuracy. The area under the ROC of the PBC score, using a cut of value 66, had a sensitivity of 81.4% and a specificity of 65.2% to classify the stage of PBC. The prevalence of PBC in Finland increases, which results from increasing incidence and improved survival. The combination of budesonide and UDCA improves liver histology compared to UDCA alone in non-cirrhotic stages of PBC. The treatment may reduce BMD. Hyaluronic acid, PIIINP, AST, and bile acids may serve as tools to monitor the treatment response in the early stages of PBC. The budesonide and UDCA combination therapy is an option for those patients who do not receive full response from UDCA and are still at the non-cirrhotic stage of PBC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the applicability of visual feedback posturography (VFP) for quantification of postural control, and to characterize the horizontal angular vestibulo-ocular reflex (AVOR) by use of a novel motorized head impulse test (MHIT). Methods: In VFP, subjects standing on a platform were instructed to move their center of gravity to symmetrically placed peripheral targets as fast and accurately as possible. The active postural control movements were measured in healthy subjects (n = 23), and in patients with vestibular schwannoma (VS) before surgery (n = 49), one month (n = 17), and three months (n = 36) after surgery. In MHIT we recorded head and eye position during motorized head impulses (mean velocity of 170º/s and acceleration of 1 550º/s²) in healthy subjects (n = 22), in patients with VS before surgery (n = 38) and about four months afterwards (n = 27). The gain, asymmetry and latency in MHIT were calculated. Results: The intraclass correlation coefficient for VFP parameters during repeated tests was significant (r = 0.78-0.96; p < 0.01), although two of four VFP parameters improved slightly during five test sessions in controls. At least one VFP parameter was abnormal pre- and postoperatively in almost half the patients, and these abnormal preoperative VFP results correlated significantly with abnormal postoperative results. The mean accuracy in postural control in patients was reduced pre- and postoperatively. A significant side difference with VFP was evident in 10% of patients. In the MHIT, the normal gain was close to unity, the asymmetry in gain was within 10%, and the latency was a mean ± standard deviation 3.4 ± 6.3 milliseconds. Ipsilateral gain or asymmetry in gain was preoperatively abnormal in 71% of patients, whereas it was abnormal in every patient after surgery. Preoperative gain (mean ± 95% confidence interval) was significantly lowered to 0.83 ± 0.08 on the ipsilateral side compared to 0.98 ± 0.06 on the contralateral side. The ipsilateral postoperative mean gain of 0.53 ± 0.05 was significantly different from preoperative gain. Conclusion: The VFP is a repeatable, quantitative method to assess active postural control within individual subjects. The mean postural control in patients with VS was disturbed before and after surgery, although not severely. Side difference in postural control in the VFP was rare. The horizontal AVOR results in healthy subjects and in patients with VS, measured with MHIT, were in agreement with published data achieved using other techniques with head impulse stimuli. The MHIT is a non-invasive method which allows reliable clinical assessment of the horizontal AVOR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis focuses on the issue of testing sleepiness quantitatively. The issue is relevant to policymakers concerned with traffic- and occupational safety; such testing provides a tool for safety legislation and -surveillance. The findings of this thesis provide guidelines for a posturographic sleepiness tester. Sleepiness ensuing from staying awake merely 17 h impairs our performance as much as the legally proscribed blood alcohol concentration 0.5 does. Hence, sleepiness is a major risk factor in transportation and occupational accidents. The lack of convenient, commercial sleepiness tests precludes testing impending sleepiness levels contrary to simply breath testing for alcohol intoxication. Posturography is a potential sleepiness test, since clinical diurnal balance testing suggests the hypothesis that time awake could be posturographically estimable. Relying on this hypothesis this thesis examines posturographic sleepiness testing for instrumentation purposes. Empirical results from 63 subjects for whom we tested balance with a force platform during wakefulness for maximum 36 h show that sustained wakefulness impairs balance. The results show that time awake is posturographically estimable with 88% accuracy and 97% precision which validates our hypothesis. Results also show that balance scores tested at 13:30 hours serve as a threshold to detect excessive sleepiness. Analytical results show that the test length has a marked effect on estimation accuracy: 18 s tests suffice to identify sleepiness related balance changes, but trades off some of the accuracy achieved with 30 s tests. The procedure to estimate time awake relies on equating the subject s test score to a reference table (comprising balance scores tested during sustained wakefulness, regressed against time awake). Empirical results showed that sustained wakefulness explains 60% of the diurnal balance variations, whereas the time of day explains 40% of the balance variations. The latter fact implies that time awake estimations also must rely on knowing the local times of both test and reference scores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiation therapy (RT) plays currently significant role in curative treatments of several cancers. External beam RT is carried out mostly by using megavoltage beams of linear accelerators. Tumor eradication and normal tissue complications correlate to dose absorbed in tissues. Normally this dependence is steep and it is crucial that actual dose within patient accurately correspond to the planned dose. All factors in a RT procedure contain uncertainties requiring strict quality assurance. From hospital physicist´s point of a view, technical quality control (QC), dose calculations and methods for verification of correct treatment location are the most important subjects. Most important factor in technical QC is the verification that radiation production of an accelerator, called output, is within narrow acceptable limits. The output measurements are carried out according to a locally chosen dosimetric QC program defining measurement time interval and action levels. Dose calculation algorithms need to be configured for the accelerators by using measured beam data. The uncertainty of such data sets limits for best achievable calculation accuracy. All these dosimetric measurements require good experience, are workful, take up resources needed for treatments and are prone to several random and systematic sources of errors. Appropriate verification of treatment location is more important in intensity modulated radiation therapy (IMRT) than in conventional RT. This is due to steep dose gradients produced within or close to healthy tissues locating only a few millimetres from the targeted volume. The thesis was concentrated in investigation of the quality of dosimetric measurements, the efficacy of dosimetric QC programs, the verification of measured beam data and the effect of positional errors on the dose received by the major salivary glands in head and neck IMRT. A method was developed for the estimation of the effect of the use of different dosimetric QC programs on the overall uncertainty of dose. Data were provided to facilitate the choice of a sufficient QC program. The method takes into account local output stability and reproducibility of the dosimetric QC measurements. A method based on the model fitting of the results of the QC measurements was proposed for the estimation of both of these factors. The reduction of random measurement errors and optimization of QC procedure were also investigated. A method and suggestions were presented for these purposes. The accuracy of beam data was evaluated in Finnish RT centres. Sufficient accuracy level was estimated for the beam data. A method based on the use of reference beam data was developed for the QC of beam data. Dosimetric and geometric accuracy requirements were evaluated for head and neck IMRT when function of the major salivary glands is intended to be spared. These criteria are based on the dose response obtained for the glands. Random measurement errors could be reduced enabling lowering of action levels and prolongation of measurement time interval from 1 month to even 6 months simultaneously maintaining dose accuracy. The combined effect of the proposed methods, suggestions and criteria was found to facilitate the avoidance of maximal dose errors of up to even about 8 %. In addition, their use may make the strictest recommended overall dose accuracy level of 3 % (1SD) achievable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar UV radiation is harmful for life on planet Earth, but fortunately the atmospheric oxygen and ozone absorb almost entirely the most energetic UVC radiation photons. However, part of the UVB radiation and much of the UVA radiation reaches the surface of the Earth, and affect human health, environment, materials and drive atmospheric and aquatic photochemical processes. In order to quantify these effects and processes there is a need for ground-based UV measurements and radiative transfer modeling to estimate the amounts of UV radiation reaching the biosphere. Satellite measurements with their near-global spatial coverage and long-term data conti-nuity offer an attractive option for estimation of the surface UV radiation. This work focuses on radiative transfer theory based methods used for estimation of the UV radiation reaching the surface of the Earth. The objectives of the thesis were to implement the surface UV algorithm originally developed at NASA Goddard Space Flight Center for estimation of the surface UV irradiance from the meas-urements of the Dutch-Finnish built Ozone Monitoring Instrument (OMI), to improve the original surface UV algorithm especially in relation with snow cover, to validate the OMI-derived daily surface UV doses against ground-based measurements, and to demonstrate how the satellite-derived surface UV data can be used to study the effects of the UV radiation. The thesis consists of seven original papers and a summary. The summary includes an introduction of the OMI instrument, a review of the methods used for modeling of the surface UV using satellite data as well as the con-clusions of the main results of the original papers. The first two papers describe the algorithm used for estimation of the surface UV amounts from the OMI measurements as well as the unique Very Fast Delivery processing system developed for processing of the OMI data received at the Sodankylä satellite data centre. The third and the fourth papers present algorithm improvements related to the surface UV albedo of the snow-covered land. Fifth paper presents the results of the comparison of the OMI-derived daily erythemal doses with those calculated from the ground-based measurement data. It gives an estimate of the expected accuracy of the OMI-derived sur-face UV doses for various atmospheric and other conditions, and discusses the causes of the differences between the satellite-derived and ground-based data. The last two papers demonstrate the use of the satellite-derived sur-face UV data. Sixth paper presents an assessment of the photochemical decomposition rates in aquatic environment. Seventh paper presents use of satellite-derived daily surface UV doses for planning of the outdoor material weathering tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis studies quantile residuals and uses different methodologies to develop test statistics that are applicable in evaluating linear and nonlinear time series models based on continuous distributions. Models based on mixtures of distributions are of special interest because it turns out that for those models traditional residuals, often referred to as Pearson's residuals, are not appropriate. As such models have become more and more popular in practice, especially with financial time series data there is a need for reliable diagnostic tools that can be used to evaluate them. The aim of the thesis is to show how such diagnostic tools can be obtained and used in model evaluation. The quantile residuals considered here are defined in such a way that, when the model is correctly specified and its parameters are consistently estimated, they are approximately independent with standard normal distribution. All the tests derived in the thesis are pure significance type tests and are theoretically sound in that they properly take the uncertainty caused by parameter estimation into account. -- In Chapter 2 a general framework based on the likelihood function and smooth functions of univariate quantile residuals is derived that can be used to obtain misspecification tests for various purposes. Three easy-to-use tests aimed at detecting non-normality, autocorrelation, and conditional heteroscedasticity in quantile residuals are formulated. It also turns out that these tests can be interpreted as Lagrange Multiplier or score tests so that they are asymptotically optimal against local alternatives. Chapter 3 extends the concept of quantile residuals to multivariate models. The framework of Chapter 2 is generalized and tests aimed at detecting non-normality, serial correlation, and conditional heteroscedasticity in multivariate quantile residuals are derived based on it. Score test interpretations are obtained for the serial correlation and conditional heteroscedasticity tests and in a rather restricted special case for the normality test. In Chapter 4 the tests are constructed using the empirical distribution function of quantile residuals. So-called Khmaladze s martingale transformation is applied in order to eliminate the uncertainty caused by parameter estimation. Various test statistics are considered so that critical bounds for histogram type plots as well as Quantile-Quantile and Probability-Probability type plots of quantile residuals are obtained. Chapters 2, 3, and 4 contain simulations and empirical examples which illustrate the finite sample size and power properties of the derived tests and also how the tests and related graphical tools based on residuals are applied in practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The TOTEM collaboration has developed and tested the first prototype of its Roman Pots to be operated in the LHC. TOTEM Roman Pots contain stacks of 10 silicon detectors with strips oriented in two orthogonal directions. To measure proton scattering angles of a few microradians, the detectors will approach the beam centre to a distance of 10 sigma + 0.5 mm (= 1.3 mm). Dead space near the detector edge is minimised by using two novel "edgeless" detector technologies. The silicon detectors are used both for precise track reconstruction and for triggering. The first full-sized prototypes of both detector technologies as well as their read-out electronics have been developed, built and operated. The tests took place first in a fixed-target muon beam at CERN's SPS, and then in the proton beam-line of the SPS accelerator ring. We present the test beam results demonstrating the successful functionality of the system despite slight technical shortcomings to be improved in the near future.