5 resultados para assessment method
em Glasgow Theses Service
Resumo:
Introduction: Free tissue transfer using an abdominal tissue flap is a commonly used method of breast reconstruction. However, there are well recognised complications including venous congestion, fat necrosis and flap loss associated with the perfusion of these flaps. Post-operative aesthetic outcome assessment of such breast reconstructions have also proven to be difficult with current methods displaying poor inter-rater reliability and patient correlation. The aim of this research was to investigate potential improvements to the post-operative outcome of free abdominal tissue transfer breast reconstruction by assessing the effects of vascular augmentation interventions on flap perfusion and to assess the use of real-time digital video as a post-operative assessment tool. Methods: An in-vivo pilot study carried out on 12 patients undergoing DIEP flap breast reconstruction assessed the effect on Zone IV perfusion, using LDI and ICG angiography, of vascular augmentation of the flap using the contralateral SIEA and SIEV. A further animal experimental study was carried out on 12 Sprague Dawley rats to assess the effects on main pedicle arterial blood flow and on Zone I and Zone IV perfusion of vascular augmentation of the abdominal flap using the contralateral vascular system. A separate post-operative assessment study was undertaken on 35 breast reconstruction patients who evaluated their own reconstructions via patient questionnaire and underwent photograph and real-time digital video capture of their reconstructions with subsequent panel assessment. Results: Our results showed that combined vascular augmentation of DIEP flaps, using both the SIEA and SIEV together, led to an increase in Zone IV perfusion. Vascular augmentation of the rat abdominal flaps also led to a significant increase in Zone I/IV perfusion, but the augmentation procedure resulted in a decreased main pedicle arterial blood flow. Our post-operative assessment study revealed that real-time digital video footage led to greater inter-rater agreement with regards to cosmesis and shape than photography and also correlated more with patient self-assessment. Conclusion: Vascular augmentation of abdominal free tissue flaps using the contralateral vascular system results in an increase to Zone IV perfusion, however this may lead to decreased main pedicle arterial blood flow. Real-time digital video is a valid post-operative aesthetic assessment method of breast reconstruction outcome and is superior to static photography when coupled with panel assessment.
Resumo:
Congenital vertebral malformations are common in brachycephalic “screw-tailed” dog breeds such as French bulldogs, English bulldogs, Boston terriers, and Pugs. Those vertebral malformations disrupt the normal vertebral column anatomy and biomechanics, potentially leading to deformity of the vertebral column and subsequent neurological dysfunction. The initial aim of this work was to study and determine whether the congenital vertebral malformations identified in those breeds could be translated in a radiographic classification scheme used in humans to give an improved classification, with clear and well-defined terminology, with the expectation that this would facilitate future study and clinical management in the veterinary field. Therefore, two observers who were blinded to the neurologic status of the dogs classified each vertebral malformation based on the human classification scheme of McMaster and were able to translate them successfully into a new classification scheme for veterinary use. The following aim was to assess the nature and the impact of vertebral column deformity engendered by those congenital vertebral malformations in the target breeds. As no gold standard exists in veterinary medicine for the calculation of the degree of deformity, it was elected to adapt the human equivalent, termed the Cobb angle, as a potential standard reference tool for use in veterinary practice. For the validation of the Cobb angle measurement method, a computerised semi-automatic technique was used and assessed by multiple independent observers. They observed not only that Kyphosis was the most common vertebral column deformity but also that patients with such deformity were found to be more likely to suffer from neurological deficits, more especially if their Cobb angle was above 35 degrees.
Resumo:
The geography of Scotland, with a highly undulating hinterland, long and indented coastline, together with a large number of islands, means that much social and economic activity is largely located at the coast. The importance of the coast is further highlighted by the large number of ecosystem services derived from the coast. The threat posed by climate change, particularly current and future sea level rise, is of considerable concern and the associated coastal erosion and coastal flooding has the potential to have a substantial effect on the socioeconomic activity of the whole country. Currently, the knowledge base of coastal erosion is poor, which serves to hinder the current and future management of the coast. This research reported here aimed to establish four key aspects of coastal erosion within Scotland: the physical susceptibility of the coast to erosion; the assets exposed to coastal erosion; the vulnerability of communities to coastal erosion; and the coastal erosion risk to those communities. Coastal erosion susceptibility was modelled here within a GIS, using data for ground elevation, rockhead elevation, wave exposure and proximity to the open coast. Combining these data produced the Underlying Physical Susceptibility Model (UPSM), in the form of a 50 m2 raster of national coverage. The Coastal Erosion Susceptibility Model (CESM) was produced with the addition of sediment supply and coastal defence data, which then moderates the outputs of the UPSM. Asset data for dwellings, key assets, transport infrastructure, historic assets, and natural assets were used along with the UPSM and CESM to assess their degree of exposure to coastal erosion. A Coastal Erosion Vulnerability Model (CEVM) was produced using Experian Mosaic Scotland (a geodemographic classification which identifies 44 different social groups within Scotland) to classify populations based upon 11 vulnerability variables. Dwellings were assigned a CESM and CEVM score in order to establish their coastal erosion risk. This research demonstrated that the issue of coastal erosion will impact on a relatively low number of properties compared to those impacted by flooding (both coastal and fluvial) as many dwellings are already protected by coastal defences. There is therefore, a considerable future liability, and great pressure for coastal defences to be maintained and upgraded in their current form. The use of the CEVM is a novel inclusion within a coastal erosion assessment for Scotland. Use of the CEVM established that coastal erosion risk is not distributed equally amongst the Scottish coastal population and highlighted that risk can be reduced by either reducing exposure or reducing vulnerability. Thus far in Scotland, reducing exposure has been the primary management approach, which has a number of implications with regards social justice. This research identified the existing data gaps that should be addressed by future research in order to further improve coastal management in Scotland. Future research should focus on assessing historical coastal change rates on a national scale, improve modelling of national scale wave exposure, enhance the information held about current coastal defences and, determine the direct and indirect economic cost associated with the loss of different asset types. It is also necessary to clarify the social justice implications of using adaptation approaches to manage coastal erosion as well as establishing a method to communicate the susceptibility, exposure, vulnerability and risk aspects whilst minimising the potential negative impacts (e.g. property blight) of releasing such information.
Resumo:
Measuring the extent to which a piece of structural timber has distorted at a macroscopic scale is fundamental to assessing its viability as a structural component. From the sawmill to the construction site, as structural timber dries, distortion can render it unsuitable for its intended purposes. This rejection of unusable timber is a considerable source of waste to the timber industry and the wider construction sector. As such, ensuring accurate measurement of distortion is a key step in addressing ineffciencies within timber processing. Currently, the FRITS frame method is the established approach used to gain an understanding of timber surface profile. The method, while reliable, is dependent upon relatively few measurements taken across a limited area of the overall surface, with a great deal of interpolation required. Further, the process is unavoidably slow and cumbersome, the immobile scanning equipment limiting where and when measurements can be taken and constricting the process as a whole. This thesis seeks to introduce LiDAR scanning as a new, alternative approach to distortion feature measurement. In its infancy as a measurement technique within timber research, the practicalities of using LiDAR scanning as a measurement method are herein demonstrated, exploiting many of the advantages the technology has over current approaches. LiDAR scanning creates a much more comprehensive image of a timber surface, generating input data multiple magnitudes larger than that of the FRITS frame. Set-up and scanning time for LiDAR is also much quicker and more flexible than existing methods. With LiDAR scanning the measurement process is freed from many of the constraints of the FRITS frame and can be done in almost any environment. For this thesis, surface scans were carried out on seven Sitka spruce samples of dimensions 48.5x102x3000mm using both the FRITS frame and LiDAR scanner. The samples used presented marked levels of distortion and were relatively free from knots. A computational measurement model was created to extract feature measurements from the raw LiDAR data, enabling an assessment of each piece of timber to be carried out in accordance with existing standards. Assessment of distortion features focused primarily on the measurement of twist due to its strong prevalence in spruce and the considerable concern it generates within the construction industry. Additional measurements of surface inclination and bow were also made with each method to further establish LiDAR's credentials as a viable alternative. Overall, feature measurements as generated by the new LiDAR method compared well with those of the established FRITS method. From these investigations recommendations were made to address inadequacies within existing measurement standards, namely their reliance on generalised and interpretative descriptions of distortion. The potential for further uses of LiDAR scanning within timber researches was also discussed.
Resumo:
Nanotechnology has revolutionised humanity's capability in building microscopic systems by manipulating materials on a molecular and atomic scale. Nan-osystems are becoming increasingly smaller and more complex from the chemical perspective which increases the demand for microscopic characterisation techniques. Among others, transmission electron microscopy (TEM) is an indispensable tool that is increasingly used to study the structures of nanosystems down to the molecular and atomic scale. However, despite the effectivity of this tool, it can only provide 2-dimensional projection (shadow) images of the 3D structure, leaving the 3-dimensional information hidden which can lead to incomplete or erroneous characterization. One very promising inspection method is Electron Tomography (ET), which is rapidly becoming an important tool to explore the 3D nano-world. ET provides (sub-)nanometer resolution in all three dimensions of the sample under investigation. However, the fidelity of the ET tomogram that is achieved by current ET reconstruction procedures remains a major challenge. This thesis addresses the assessment and advancement of electron tomographic methods to enable high-fidelity three-dimensional investigations. A quality assessment investigation was conducted to provide a quality quantitative analysis of the main established ET reconstruction algorithms and to study the influence of the experimental conditions on the quality of the reconstructed ET tomogram. Regular shaped nanoparticles were used as a ground-truth for this study. It is concluded that the fidelity of the post-reconstruction quantitative analysis and segmentation is limited, mainly by the fidelity of the reconstructed ET tomogram. This motivates the development of an improved tomographic reconstruction process. In this thesis, a novel ET method was proposed, named dictionary learning electron tomography (DLET). DLET is based on the recent mathematical theorem of compressed sensing (CS) which employs the sparsity of ET tomograms to enable accurate reconstruction from undersampled (S)TEM tilt series. DLET learns the sparsifying transform (dictionary) in an adaptive way and reconstructs the tomogram simultaneously from highly undersampled tilt series. In this method, the sparsity is applied on overlapping image patches favouring local structures. Furthermore, the dictionary is adapted to the specific tomogram instance, thereby favouring better sparsity and consequently higher quality reconstructions. The reconstruction algorithm is based on an alternating procedure that learns the sparsifying dictionary and employs it to remove artifacts and noise in one step, and then restores the tomogram data in the other step. Simulation and real ET experiments of several morphologies are performed with a variety of setups. Reconstruction results validate its efficiency in both noiseless and noisy cases and show that it yields an improved reconstruction quality with fast convergence. The proposed method enables the recovery of high-fidelity information without the need to worry about what sparsifying transform to select or whether the images used strictly follow the pre-conditions of a certain transform (e.g. strictly piecewise constant for Total Variation minimisation). This can also avoid artifacts that can be introduced by specific sparsifying transforms (e.g. the staircase artifacts the may result when using Total Variation minimisation). Moreover, this thesis shows how reliable elementally sensitive tomography using EELS is possible with the aid of both appropriate use of Dual electron energy loss spectroscopy (DualEELS) and the DLET compressed sensing algorithm to make the best use of the limited data volume and signal to noise inherent in core-loss electron energy loss spectroscopy (EELS) from nanoparticles of an industrially important material. Taken together, the results presented in this thesis demonstrates how high-fidelity ET reconstructions can be achieved using a compressed sensing approach.