4 resultados para Time-Lapse Imaging

em Glasgow Theses Service


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents quantitative studies of T cell and dendritic cell (DC) behaviour in mouse lymph nodes (LNs) in the naive state and following immunisation. These processes are of importance and interest in basic immunology, and better understanding could improve both diagnostic capacity and therapeutic manipulations, potentially helping in producing more effective vaccines or developing treatments for autoimmune diseases. The problem is also interesting conceptually as it is relevant to other fields where 3D movement of objects is tracked with a discrete scanning interval. A general immunology introduction is presented in chapter 1. In chapter 2, I apply quantitative methods to multi-photon imaging data to measure how T cells and DCs are spatially arranged in LNs. This has been previously studied to describe differences between the naive and immunised state and as an indicator of the magnitude of the immune response in LNs, but previous analyses have been generally descriptive. The quantitative analysis shows that some of the previous conclusions may have been premature. In chapter 3, I use Bayesian state-space models to test some hypotheses about the mode of T cell search for DCs. A two-state mode of movement where T cells can be classified as either interacting to a DC or freely migrating is supported over a model where T cells would home in on DCs at distance through for example the action of chemokines. In chapter 4, I study whether T cell migration is linked to the geometric structure of the fibroblast reticular network (FRC). I find support for the hypothesis that the movement is constrained to the fibroblast reticular cell (FRC) network over an alternative 'random walk with persistence time' model where cells would move randomly, with a short-term persistence driven by a hypothetical T cell intrinsic 'clock'. I also present unexpected results on the FRC network geometry. Finally, a quantitative method is presented for addressing some measurement biases inherent to multi-photon imaging. In all three chapters, novel findings are made, and the methods developed have the potential for further use to address important problems in the field. In chapter 5, I present a summary and synthesis of results from chapters 3-4 and a more speculative discussion of these results and potential future directions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Glioblastoma (GBM) is a highly aggressive and fatal brain cancer that is associated with a number of diagnostic, therapeutic, and treatment monitoring challenges. At the time of writing, inhibition of a protein called poly (ADP-ribose) polymerase-1 (PARP-1) in combination with chemotherapy was being investigated as a novel approach for the treatment of these tumours. However, human studies have encountered toxicity problems due to sub-optimal PARP-1 inhibitor and chemotherapeutic dosing regiments. Nuclear imaging of PARP-1 could help to address these issues and provide additional insight into potential PARP-1 inhibitor resistance mechanisms. Furthermore, nuclear imaging of the translocator protein (TSPO) could be used to improve GBM diagnosis, pre-surgical planning, and treatment monitoring as TSPO is overexpressed by GBM lesions in good contrast to surrounding brain tissue. To date, relatively few nuclear imaging radiotracers have been discovered for PARP-1. On the other hand, numerous tracers exist for TSPO many of which have been investigated in humans. However, these TSPO radiotracers suffer from either poor pharmacokinetic properties or high sensitivity to human TSPO polymorphism that can affect their binding to TSPO. Bearing in mind the above and the high attrition rates associated with advancement of radiotracers to the clinic, there is a need for novel radiotracers that can be used to image PARP-1 and TSPO. This thesis reports the pre-clinical discovery programme that led to the identification of two potent PARP-1 inhibitors, 4 and 17, that were successfully radiolabelled to generate the potential SPECT and PET imaging agents [123I]-4 and [18F]-17 respectively. Evaluation of these radiotracers in mice bearing subcutaneous human GBM xenografts using ex vivo biodistribution techniques revealed that the agents were retained in tumour tissue due to specific PARP-1 binding. This thesis also describes the pre-clinical in vivo evaluation of [18F]-AB5186, which is a novel radiotracer discovered previously within the research group with potential for PET imaging of TSPO. Using ex vivo autoradiography and PET imaging the agent was revealed to accumulate in intracranial human GBM tumour xenografts in good contrast to surrounding brain tissue, which was due to specific binding to TSPO. The in vivo data for all three radiolabelled compounds warrants further pre-clinical investigations with potential for clinical advancement in mind.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Intravenous thrombolysis in acute ischaemic stroke with alteplase improves clinical outcomes, but it has limited efficacy and is associated with increased risk of intracranial haemorrhage. An improved tissue plasminogen activator, tenecteplase, was evidenced to be at least equally effective with lower risk of haemorrhage in acute myocardial infarction thrombolysis. To date, two completed phase II randomised controlled studies comparing tenecteplase and alteplase in acute ischaemic strokes showed variable results. Methods: A literature review of thrombolytic agents used in myocardial infarction and acute ischaemic stroke was performed, followed by a retrospective investigation of the bolus-to- infusion delay of alteplase administration. The main focus of this thesis is the report of our single centre phase II randomised controlled trial that compared tenecteplase (0.25mg/kg, maximum 25mg) and alteplase (0.9mg/kg, maximum 90mg, 10% as the initial bolus, following by one hour infusion with the rest of the dose) in acute ischaemic stroke thrombolysis using advanced imaging as biomarkers. Imaging comprised baseline computed tomography (CT), CT perfusion (CTP) and CT angiography (CTA), and CT+CTA at 24-48 hours. The primary end-point was penumbral salvage (CTP-defined penumbra volume minus follow-up CT infarct volume). A sub-study of coagulation and fibrinolysis analysis of the two agents was performed by comparing a group of coagulation variables measured pre-treatment, 3-12 hours, and 24±3 hours post thrombolysis. An individual patient data (IPD) meta-analysis was carried out using all three completed tenecteplase/alteplase comparison studies in stroke thrombolysis. We compared clinical outcomes including modified Rankin scale at 3 months, early neurological improvement at 24 hours, intracerebral haemorrhage rate and mortality at 3 months between all three tenecteplase doses (0.1mg/kg, 0.25 mg/kg, and 0.4mg/kg) examined and standard alteplase. Imaging outcomes including penumbra salvage, recanalisation rates were also compared using the data from the two studies that had advance imaging carried out. Results: Delay between the initial bolus and the subsequent infusion in administration of alteplase is common. This may reduce the likelihood of achieving a good functional outcome. Among the 104 patients recruited in ATTEST trial, 71 contributed to the imaging primary outcome. No significant differences were observed for penumbral salvage [68 (SD 28) % tenecteplase vs 68 (SD 23) % alteplase], mean difference 1% (95% confidence interval -10%, 12%, p=0·81) or for any secondary end-point. The SICH incidence (1/52, 2% vs 2/51, 4%, by SITS-MOST definition, p=0·55; by ECASS-2 definition, 3/52, 6% tenecteplase vs 4/51, 8% alteplase, p=0.59) did not differed significantly. There was a trend towards lower ICH risk in the tenecteplase group (8/52 tenecteplase, 15% vs 14/51 alteplase, 29%, p=0·091). Compared to baseline, alteplase caused significant hypofibrinogenaemia (p=0.002), prolonged Prothrombin Time (PT) (p=0.011), hypoplasminogenaemia (p=0.001) and lower Factor V (p=0.002) at 3-12 hours after administration with persistent hypofibrinogenaemia at 24h (p=0.011), while only minor hypoplasminogenaemia (P=0.029) was seen in the tenecteplase group. Tenecteplase consumed less plasminogen (p<0.001) and fibrinogen (p=0.002) compared with alteplase. In a pooled analysis, tenecteplase 0.25mg/kg had the greatest odds to achieve early neurological improvement (OR [95%CI] 3.3 [1.5, 7.2], p=0.093), excellent functional outcome (mRS 0-1) at three months (OR [95%CI] 1.9 [0.8, 4.4], p= 0.28), with reduced odds of ICH (OR [95%CI] 0.6 [0.2, 1.8], P=0.43) compared with alteplase. Only 19 patients were treated with tenecteplase 0.4mg/kg, which showed increased odds of SICH compared with alteplase (OR [95% CI] 6.2 [0.7, 56.3]). In the two studies where advanced imaging was performed, the imaging outcomes did not differ in the IPD analysis. Conclusion: Tenecteplase 0.25 mg/kg has the potential to be a better alternative to alteplase. It can be given as a single bolus, does not cause disruption to systemic coagulation, and is possibly safer and more effective in clot lysis. Further phase III study to compare tenecteplase and alteplase in acute ischaemic stroke is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis describes the application of multispectral imaging to several novel oximetry applications. Chapter 1 motivates optical microvascular oximetry, outlines oxygen transport in the body, describes the theory of oximetry, and describes the challenges associated with in vivo oximetry, in particular imaging through tissue. Chapter 2 reviews various imaging techniques for quantitative in vivo oximetry of the microvasculature, including multispectral and hyperspectral imaging, photoacoustic imaging, optical coherence tomography, and laser speckle techniques. Chapter 3 describes a two-wavelength oximetry study of two microvascular beds in the anterior segment of the eye: the bulbar conjunctival and episcleral microvasculature. This study reveals previously unseen oxygen diffusion from ambient air into the bulbar conjunctival microvasculature, altering the oxygen saturation of the bulbar conjunctiva. The response of the bulbar conjunctival and episcleral microvascular beds to acute mild hypoxia is quantified and the rate at which oxygen diffuses into bulbar conjunctival vessels is measured. Chapter 4 describes the development and application of a highly novel non-invasive retinal angiography technique: Oximetric Ratio Contrast Angiography (ORCA). ORCA requires only multispectral imaging and a small perturbation of blood oxygen saturation to produce angiographic sequences. A pilot study of ORCA in human subjects was conducted. This study demonstrates that ORCA can produce angiographic sequences with features such as sequential vessel filling and laminar flow. The application and challenges of ORCA are discussed, with emphasis on comparison with other angiography techniques, such as fluorescein angiography. Chapter 5 describes the development of a multispectral microscope for oximetry in the spinal cord dorsal vein of rats. Measurements of blood oxygen saturation are made in the dorsal vein of both healthy rats, and in rats with the Experimental autoimmune encephalomyelitis (EAE) disease model of multiple sclerosis. The venous blood oxygen saturation of EAE disease model rats was found to be significantly lower than that of healthy controls, indicating increased oxygen uptake from blood in the EAE disease model of multiple sclerosis. Chapter 6 describes the development of video-rate red eye oximetry; a technique which could enable stand-off oximetry of the blood-supply of the eye with high temporal resolution. The various challenges associated with video-rate red eye oximetry are investigated and their influence quantified. The eventual aim of this research is to track circulating deoxygenation perturbations as they arrive in both eyes, which could provide a screening method for carotid artery stenosis, which is major risk-factor for stroke. However, due to time constraints, it was not possible to thoroughly investigate if video-rate red eye can detect such perturbations. Directions and recommendations for future research are outlined.