4 resultados para Heat warning system

em Glasgow Theses Service


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The next generation of vehicles will be equipped with automated Accident Warning Systems (AWSs) capable of warning neighbouring vehicles about hazards that might lead to accidents. The key enabling technology for these systems is the Vehicular Ad-hoc Networks (VANET) but the dynamics of such networks make the crucial timely delivery of warning messages challenging. While most previously attempted implementations have used broadcast-based data dissemination schemes, these do not cope well as data traffic load or network density increases. This problem of sending warning messages in a timely manner is addressed by employing a network coding technique in this thesis. The proposed NETwork COded DissEmination (NETCODE) is a VANET-based AWS responsible for generating and sending warnings to the vehicles on the road. NETCODE offers an XOR-based data dissemination scheme that sends multiple warning in a single transmission and therefore, reduces the total number of transmissions required to send the same number of warnings that broadcast schemes send. Hence, it reduces contention and collisions in the network improving the delivery time of the warnings. The first part of this research (Chapters 3 and 4) asserts that in order to build a warning system, it is needful to ascertain the system requirements, information to be exchanged, and protocols best suited for communication between vehicles. Therefore, a study of these factors along with a review of existing proposals identifying their strength and weakness is carried out. Then an analysis of existing broadcast-based warning is conducted which concludes that although this is the most straightforward scheme, loading can result an effective collapse, resulting in unacceptably long transmission delays. The second part of this research (Chapter 5) proposes the NETCODE design, including the main contribution of this thesis, a pair of encoding and decoding algorithms that makes the use of an XOR-based technique to reduce transmission overheads and thus allows warnings to get delivered in time. The final part of this research (Chapters 6--8) evaluates the performance of the proposed scheme as to how it reduces the number of transmissions in the network in response to growing data traffic load and network density and investigates its capacity to detect potential accidents. The evaluations use a custom-built simulator to model real-world scenarios such as city areas, junctions, roundabouts, motorways and so on. The study shows that the reduction in the number of transmissions helps reduce competition in the network significantly and this allows vehicles to deliver warning messages more rapidly to their neighbours. It also examines the relative performance of NETCODE when handling both sudden event-driven and longer-term periodic messages in diverse scenarios under stress caused by increasing numbers of vehicles and transmissions per vehicle. This work confirms the thesis' primary contention that XOR-based network coding provides a potential solution on which a more efficient AWS data dissemination scheme can be built.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This portfolio thesis describes work undertaken by the author under the Engineering Doctorate program of the Institute for System Level Integration. It was carried out in conjunction with the sponsor company Teledyne Defence Limited. A radar warning receiver is a device used to detect and identify the emissions of radars. They were originally developed during the Second World War and are found today on a variety of military platforms as part of the platform’s defensive systems. Teledyne Defence has designed and built components and electronic subsystems for the defence industry since the 1970s. This thesis documents part of the work carried out to create Phobos, Teledyne Defence’s first complete radar warning receiver. Phobos was designed to be the first low cost radar warning receiver. This was made possible by the reuse of existing Teledyne Defence products, commercial off the shelf hardware and advanced UK government algorithms. The challenges of this integration are described and discussed, with detail given of the software architecture and the development of the embedded application. Performance of the embedded system as a whole is described and qualified within the context of a low cost system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The value of integrating a heat storage into a geothermal district heating system has been investigated. The behaviour of the system under a novel operational strategy has been simulated focusing on the energetic, economic and environmental effects of the new strategy of incorporation of the heat storage within the system. A typical geothermal district heating system consists of several production wells, a system of pipelines for the transportation of the hot water to end-users, one or more re-injection wells and peak-up devices (usually fossil-fuel boilers). Traditionally in these systems, the production wells change their production rate throughout the day according to heat demand, and if their maximum capacity is exceeded the peak-up devices are used to meet the balance of the heat demand. In this study, it is proposed to maintain a constant geothermal production and add heat storage into the network. Subsequently, hot water will be stored when heat demand is lower than the production and the stored hot water will be released into the system to cover the peak demands (or part of these). It is not intended to totally phase-out the peak-up devices, but to decrease their use, as these will often be installed anyway for back-up purposes. Both the integration of a heat storage in such a system as well as the novel operational strategy are the main novelties of this thesis. A robust algorithm for the sizing of these systems has been developed. The main inputs are the geothermal production data, the heat demand data throughout one year or more and the topology of the installation. The outputs are the sizing of the whole system, including the necessary number of production wells, the size of the heat storage and the dimensions of the pipelines amongst others. The results provide several useful insights into the initial design considerations for these systems, emphasizing particularly the importance of heat losses. Simulations are carried out for three different cases of sizing of the installation (small, medium and large) to examine the influence of system scale. In the second phase of work, two algorithms are developed which study in detail the operation of the installation throughout a random day and a whole year, respectively. The first algorithm can be a potentially powerful tool for the operators of the installation, who can know a priori how to operate the installation on a random day given the heat demand. The second algorithm is used to obtain the amount of electricity used by the pumps as well as the amount of fuel used by the peak-up boilers over a whole year. These comprise the main operational costs of the installation and are among the main inputs of the third part of the study. In the third part of the study, an integrated energetic, economic and environmental analysis of the studied installation is carried out together with a comparison with the traditional case. The results show that by implementing heat storage under the novel operational strategy, heat is generated more cheaply as all the financial indices improve, more geothermal energy is utilised and less fuel is used in the peak-up boilers, with subsequent environmental benefits, when compared to the traditional case. Furthermore, it is shown that the most attractive case of sizing is the large one, although the addition of the heat storage most greatly impacts the medium case of sizing. In other words, the geothermal component of the installation should be sized as large as possible. This analysis indicates that the proposed solution is beneficial from energetic, economic, and environmental perspectives. Therefore, it can be stated that the aim of this study is achieved in its full potential. Furthermore, the new models for the sizing, operation and economic/energetic/environmental analyses of these kind of systems can be used with few adaptations for real cases, making the practical applicability of this study evident. Having this study as a starting point, further work could include the integration of these systems with end-user demands, further analysis of component parts of the installation (such as the heat exchangers) and the integration of a heat pump to maximise utilisation of geothermal energy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different types of base fluids, such as water, engine oil, kerosene, ethanol, methanol, ethylene glycol etc. are usually used to increase the heat transfer performance in many engineering applications. But these conventional heat transfer fluids have often several limitations. One of those major limitations is that the thermal conductivity of each of these base fluids is very low and this results a lower heat transfer rate in thermal engineering systems. Such limitation also affects the performance of different equipments used in different heat transfer process industries. To overcome such an important drawback, researchers over the years have considered a new generation heat transfer fluid, simply known as nanofluid with higher thermal conductivity. This new generation heat transfer fluid is a mixture of nanometre-size particles and different base fluids. Different researchers suggest that adding spherical or cylindrical shape of uniform/non-uniform nanoparticles into a base fluid can remarkably increase the thermal conductivity of nanofluid. Such augmentation of thermal conductivity could play a more significant role in enhancing the heat transfer rate than that of the base fluid. Nanoparticles diameters used in nanofluid are usually considered to be less than or equal to 100 nm and the nanoparticles concentration usually varies from 5% to 10%. Different researchers mentioned that the smaller nanoparticles concentration with size diameter of 100 nm could enhance the heat transfer rate more significantly compared to that of base fluids. But it is not obvious what effect it will have on the heat transfer performance when nanofluids contain small size nanoparticles of less than 100 nm with different concentrations. Besides, the effect of static and moving nanoparticles on the heat transfer of nanofluid is not known too. The idea of moving nanoparticles brings the effect of Brownian motion of nanoparticles on the heat transfer. The aim of this work is, therefore, to investigate the heat transfer performance of nanofluid using a combination of smaller size of nanoparticles with different concentrations considering the Brownian motion of nanoparticles. A horizontal pipe has been considered as a physical system within which the above mentioned nanofluid performances are investigated under transition to turbulent flow conditions. Three different types of numerical models, such as single phase model, Eulerian-Eulerian multi-phase mixture model and Eulerian-Lagrangian discrete phase model have been used while investigating the performance of nanofluids. The most commonly used model is single phase model which is based on the assumption that nanofluids behave like a conventional fluid. The other two models are used when the interaction between solid and fluid particles is considered. However, two different phases, such as fluid and solid phases is also considered in the Eulerian-Eulerian multi-phase mixture model. Thus, these phases create a fluid-solid mixture. But, two phases in the Eulerian-Lagrangian discrete phase model are independent. One of them is a solid phase and the other one is a fluid phase. In addition, RANS (Reynolds Average Navier Stokes) based Standard κ-ω and SST κ-ω transitional models have been used for the simulation of transitional flow. While the RANS based Standard κ-ϵ, Realizable κ-ϵ and RNG κ-ϵ turbulent models are used for the simulation of turbulent flow. Hydrodynamic as well as temperature behaviour of transition to turbulent flows of nanofluids through the horizontal pipe is studied under a uniform heat flux boundary condition applied to the wall with temperature dependent thermo-physical properties for both water and nanofluids. Numerical results characterising the performances of velocity and temperature fields are presented in terms of velocity and temperature contours, turbulent kinetic energy contours, surface temperature, local and average Nusselt numbers, Darcy friction factor, thermal performance factor and total entropy generation. New correlations are also proposed for the calculation of average Nusselt number for both the single and multi-phase models. Result reveals that the combination of small size of nanoparticles and higher nanoparticles concentrations with the Brownian motion of nanoparticles shows higher heat transfer enhancement and thermal performance factor than those of water. Literature suggests that the use of nanofluids flow in an inclined pipe at transition to turbulent regimes has been ignored despite its significance in real-life applications. Therefore, a particular investigation has been carried out in this thesis with a view to understand the heat transfer behaviour and performance of an inclined pipe under transition flow condition. It is found that the heat transfer rate decreases with the increase of a pipe inclination angle. Also, a higher heat transfer rate is found for a horizontal pipe under forced convection than that of an inclined pipe under mixed convection.