3 resultados para Accelerometers.
em Glasgow Theses Service
Resumo:
Background Physical activity in children with intellectual disabilities is a neglected area of study, which is most apparent in relation to physical activity measurement research. Although objective measures, specifically accelerometers, are widely used in research involving children with intellectual disabilities, existing research is based on measurement methods and data interpretation techniques generalised from typically developing children. However, due to physiological and biomechanical differences between these populations, questions have been raised in the existing literature on the validity of generalising data interpretation techniques from typically developing children to children with intellectual disabilities. Therefore, there is a need to conduct population-specific measurement research for children with intellectual disabilities and develop valid methods to interpret accelerometer data, which will increase our understanding of physical activity in this population. Methods Study 1: A systematic review was initially conducted to increase the knowledge base on how accelerometers were used within existing physical activity research involving children with intellectual disabilities and to identify important areas for future research. A systematic search strategy was used to identify relevant articles which used accelerometry-based monitors to quantify activity levels in ambulatory children with intellectual disabilities. Based on best practice guidelines, a novel form was developed to extract data based on 17 research components of accelerometer use. Accelerometer use in relation to best practice guidelines was calculated using percentage scores on a study-by-study and component-by-component basis. Study 2: To investigate the effect of data interpretation methods on the estimation of physical activity intensity in children with intellectual disabilities, a secondary data analysis was conducted. Nine existing sets of child-specific ActiGraph intensity cut points were applied to accelerometer data collected from 10 children with intellectual disabilities during an activity session. Four one-way repeated measures ANOVAs were used to examine differences in estimated time spent in sedentary, moderate, vigorous, and moderate to vigorous intensity activity. Post-hoc pairwise comparisons with Bonferroni adjustments were additionally used to identify where significant differences occurred. Study 3: The feasibility on a laboratory-based calibration protocol developed for typically developing children was investigated in children with intellectual disabilities. Specifically, the feasibility of activities, measurements, and recruitment was investigated. Five children with intellectual disabilities and five typically developing children participated in 14 treadmill-based and free-living activities. In addition, resting energy expenditure was measured and a treadmill-based graded exercise test was used to assess cardiorespiratory fitness. Breath-by-breath respiratory gas exchange and accelerometry were continually measured during all activities. Feasibility was assessed using observations, activity completion rates, and respiratory data. Study 4: Thirty-six children with intellectual disabilities participated in a semi-structured school-based physical activity session to calibrate accelerometry for the estimation of physical activity intensity. Participants wore a hip-mounted ActiGraph wGT3X+ accelerometer, with direct observation (SOFIT) used as the criterion measure. Receiver operating characteristic curve analyses were conducted to determine the optimal accelerometer cut points for sedentary, moderate, and vigorous intensity physical activity. Study 5: To cross-validate the calibrated cut points and compare classification accuracy with existing cut points developed in typically developing children, a sub-sample of 14 children with intellectual disabilities who participated in the school-based sessions, as described in Study 4, were included in this study. To examine the validity, classification agreement was investigated between the criterion measure of SOFIT and each set of cut points using sensitivity, specificity, total agreement, and Cohen’s kappa scores. Results Study 1: Ten full text articles were included in this review. The percentage of review criteria met ranged from 12%−47%. Various methods of accelerometer use were reported, with most use decisions not based on population-specific research. A lack of measurement research, specifically the calibration/validation of accelerometers for children with intellectual disabilities, is limiting the ability of researchers to make appropriate and valid accelerometer use decisions. Study 2: The choice of cut points had significant and clinically meaningful effects on the estimation of physical activity intensity and sedentary behaviour. For the 71-minute session, estimations for time spent in each intensity between cut points ranged from: sedentary = 9.50 (± 4.97) to 31.90 (± 6.77) minutes; moderate = 8.10 (± 4.07) to 40.40 (± 5.74) minutes; vigorous = 0.00 (± .00) to 17.40 (± 6.54) minutes; and moderate to vigorous = 8.80 (± 4.64) to 46.50 (± 6.02) minutes. Study 3: All typically developing participants and one participant with intellectual disabilities completed the protocol. No participant met the maximal criteria for the graded exercise test or attained a steady state during the resting measurements. Limitations were identified with the usability of respiratory gas exchange equipment and the validity of measurements. The school-based recruitment strategy was not effective, with a participation rate of 6%. Therefore, a laboratory-based calibration protocol was not feasible for children with intellectual disabilities. Study 4: The optimal vertical axis cut points (cpm) were ≤ 507 (sedentary), 1008−2300 (moderate), and ≥ 2301 (vigorous). Sensitivity scores ranged from 81−88%, specificity 81−85%, and AUC .87−.94. The optimal vector magnitude cut points (cpm) were ≤ 1863 (sedentary), ≥ 2610 (moderate) and ≥ 4215 (vigorous). Sensitivity scores ranged from 80−86%, specificity 77−82%, and AUC .86−.92. Therefore, the vertical axis cut points provide a higher level of accuracy in comparison to the vector magnitude cut points. Study 5: Substantial to excellent classification agreement was found for the calibrated cut points. The calibrated sedentary cut point (ĸ =.66) provided comparable classification agreement with existing cut points (ĸ =.55−.67). However, the existing moderate and vigorous cut points demonstrated low sensitivity (0.33−33.33% and 1.33−53.00%, respectively) and disproportionately high specificity (75.44−.98.12% and 94.61−100.00%, respectively), indicating that cut points developed in typically developing children are too high to accurately classify physical activity intensity in children with intellectual disabilities. Conclusions The studies reported in this thesis are the first to calibrate and validate accelerometry for the estimation of physical activity intensity in children with intellectual disabilities. In comparison with typically developing children, children with intellectual disabilities require lower cut points for the classification of moderate and vigorous intensity activity. Therefore, generalising existing cut points to children with intellectual disabilities will underestimate physical activity and introduce systematic measurement error, which could be a contributing factor to the low levels of physical activity reported for children with intellectual disabilities in previous research.
Resumo:
South Asians migrating to the Western world have a 3 to 5-fold higher risk of developing type 2 diabetes and double the risk of cardiovascular disease (CVD) than the background population of White European descent, without exhibiting a proportional higher prevalence of conventional cardiometabolic risk factors. Notably, women of South Asian descent are more likely to be diagnosed with type 2 diabetes as they grow older compared with South Asian men and, in addition, they have lost the cardio-protective effects of being females. Despite South Asian women in Western countries being a high risk group for developing future type 2 diabetes and CVD, they have been largely overlooked. The aims of this thesis were to compare lifestyle factors, body composition and cardiometabolic risk factors in healthy South Asian and European women who reside in Scotland, to examine whether ethnicity modifies the associations between modifiable environmental factors and cardiometabolic risks and to assess whether vascular reactivity is altered by ethnicity or other conventional and novel CVD risks. I conducted a cross-sectional study and recruited 92 women of South Asian and 87 women of White European descent without diagnosed diabetes or CVD. Women on hormone replacement therapy or hormonal contraceptives were excluded too. Age and body mass index (BMI) did not differ between the two ethnic groups. Physical activity was assessed and with self-reported questionnaires and objectively with the use of accelerometers. Cardiorespiratory fitness was quantified with the predicted maximal oxygen uptake (VO2 max) during a submaximal test (Chester step test). Body composition was assessed with skinfolds measured at seven body sites, five body circumferences, measurement of abdominal subcutaneous (SAT) and visceral adipose tissue (VAT) with the use of magnetic resonance imaging (MRI) and liver fat with the use MR spectroscopy. Dietary density was assessed with food frequency questionnaires. Vascular response was assessed by measuring the response to acetylcholine and sodium nitroprusside with the use of Laser Doppler Imaging with Iontophoresis (LDI-ION) and the response to shear stress with the use of Peripheral Arterial Tonometry (EndoPAT). The South Asian women exhibited a metabolic profile consistent with the insulin resistant phenotype, characterised by greater levels of fasting insulin, lower levels of high density lipoprotein (HDL) and higher levels of triglycerides (TG) compared with their European counterparts. In addition, the South Asians had greater levels of glycated haemoglobin (HbA1c) for any given level of fasting glucose. The South Asian women engaged less time weekly with moderate to vigorous physical activity (MVPA) and had lower levels of cardiorespiratory fitness for any given level of physical activity than the women of White descent. In addition, they accumulated more fat centrally for any given BMI. Notably, the South Asians had equivalent SAT with the European women but greater VAT and hepatic fat for any given BMI. Dietary density did not differ among the groups. Increasing central adiposity had the largest effect on insulin resistance in both ethic groups compared with physical inactivity or decreased cardiorespiratory fitness. Interestingly, ethnicity modified the association between central adiposity and insulin resistance index with a similar increase in central adiposity having a substantially larger effect on insulin resistance index in the South Asian women than in the Europeans. I subsequently examined whether ethnic specific thresholds are required for lifestyle modifications and demonstrated that South Asian women need to engage with MVPA for around 195 min.week-1 in order to equate their cardiometabolic risk with that of the Europeans exercising 150 min.week-1. In addition, lower thresholds of abdominal adiposity and BMI should apply for the South Asians compared with the conventional thresholds. Although the South Asians displayed an adverse metabolic profile, vascular reactivity measured with both methods did not differ among the two groups. An additional finding was that menopausal women with hot flushing of both ethnic groups showed a paradoxical vascular profile with enhanced skin perfusion (measured with LDI-ION) but decreased reactive hyperaemia index (measured with EndoPAT) compared with asymptomatic menopausal women. The latter association was independent of conventional CVD risk factors. To conclude, South Asian women without overt disease who live in Scotland display an adverse metabolic profile with steeper associations between lifestyle risk factors and adverse cardiometabolic outcomes compared with their White counterparts. Further work in exploring ethnic specific thresholds in lifestyle interventions or in disease diagnosis is warranted.
Resumo:
The ability to measure tiny variations in the local gravitational acceleration allows – amongst other applications – the detection of hidden hydrocarbon reserves, magma build-up before volcanic eruptions, and subterranean tunnels. Several technologies are available that achieve the sensitivities required (tens of μGal/√Hz), and stabilities required (periods of days to weeks) for such applications: free-fall gravimeters, spring-based gravimeters, superconducting gravimeters, and atom interferometers. All of these devices can observe the Earth tides; the elastic deformation of the Earth’s crust as a result of tidal forces. This is a universally predictable gravitational signal that requires both high sensitivity and high stability over timescales of several days to measure. All present gravimeters, however, have limitations of excessive cost (£70 k) and high mass (<8 kg). In this thesis, the building of a microelectromechanical system (MEMS) gravimeter with a sensitivity of 40 μGal/√Hz in a package size of only a few cubic centimetres is discussed. MEMS accelerometers – found in most smart phones – can be mass-produced remarkably cheaply, but most are not sensitive enough, and none have been stable enough to be called a ‘gravimeter’. The remarkable stability and sensitivity of the device is demonstrated with a measurement of the Earth tides. Such a measurement has never been undertaken with a MEMS device, and proves the long term stability of the instrument compared to any other MEMS device, making it the first MEMS accelerometer that can be classed as a gravimeter. This heralds a transformative step in MEMS accelerometer technology. Due to their small size and low cost, MEMS gravimeters could create a new paradigm in gravity mapping: exploration surveys could be carried out with drones instead of low-flying aircraft; they could be used for distributed land surveys in exploration settings, for the monitoring of volcanoes; or built into multi-pixel density contrast imaging arrays.