3 resultados para polymer optical flber (POF)

em eResearch Archive - Queensland Department of Agriculture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical peanut yield monitor was developed, fabricated, and field-tested. The overall system includes an optical mass-flow sensor, a GPS receiver, and a data acquisition system. The concept for the mass-flow sensor is based on that of the cotton yield-monitor sensor developed previously by Thomasson and Sui (2000). A modified version of the sensor was designed to be specific to peanut mass-flow measurement. Field testing of the peanut yield monitor was conducted in Australia during the May 2003 harvest. After subsequent minor modifications, the system was more extensively tested in Mississippi in October of 2003 and November of 2004. Test results showed that the output of the peanut mass-flow sensor was very strongly correlated with the harvested load weight, and the system's performance was stable and reliable during the tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sorghum ergot, caused by Claviceps africana, has remained a major disease problem in Australia since it was first recorded in 1996, and is the focus of a range of biological and integrated management research. Artificial inoculation using conidial suspensions is an important tool in this research. Ergot infection is greatly influenced by environmental factors, so it is important to reduce controllable sources of variation such as inoculum concentration. The use of optical density was tested as a method of quantifying conidial suspensions of C. africana, as an alternative to haemocytometer counts. This method was found to be accurate and time efficient, with possible applications in other disease systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A commercial non-specific gas sensor array system was evaluated in terms of its capability to monitor the odour abatement performance of a biofiltration system developed for treating emissions from a commercial piggery building. The biofiltration system was a modular system comprising an inlet ducting system, humidifier and closed-bed biofilter. It also included a gravimetric moisture monitoring and water application system for precise control of moisture content of an organic woodchip medium. Principal component analysis (PCA) of the sensor array measurements indicated that the biofilter outlet air was significantly different to both inlet air of the system and post-humidifier air. Data pre-processing techniques including normalising and outlier handling were applied to improve the odour discrimination performance of the non-specific gas sensor array. To develop an odour quantification model using the sensor array responses of the non-specific sensor array, PCA regression, artificial neural network (ANN) and partial least squares (PLS) modelling techniques were applied. The correlation coefficient (r(2)) values of the PCA, ANN, and PLS models were 0.44, 0.62 and 0.79, respectively.