2 resultados para Silica-on-silicon

em eResearch Archive - Queensland Department of Agriculture


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent decreases in costs, and improvements in performance, of silicon array detectors open a range of potential applications of relevance to plant physiologists, associated with spectral analysis in the visible and short-wave near infra-red (far-red) spectrum. The performance characteristics of three commercially available ‘miniature’ spectrometers based on silicon array detectors operating in the 650–1050-nm spectral region (MMS1 from Zeiss, S2000 from Ocean Optics, and FICS from Oriel, operated with a Larry detector) were compared with respect to the application of non-invasive prediction of sugar content of fruit using near infra-red spectroscopy (NIRS). The FICS–Larry gave the best wavelength resolution; however, the narrow slit and small pixel size of the charge-coupled device detector resulted in a very low sensitivity, and this instrumentation was not considered further. Wavelength resolution was poor with the MMS1 relative to the S2000 (e.g. full width at half maximum of the 912 nm Hg peak, 13 and 2 nm for the MMS1 and S2000, respectively), but the large pixel height of the array used in the MMS1 gave it sensitivity comparable to the S2000. The signal-to-signal standard error ratio of spectra was greater by an order of magnitude with the MMS1, relative to the S2000, at both near saturation and low light levels. Calibrations were developed using reflectance spectra of filter paper soaked in range of concentrations (0–20% w/v) of sucrose, using a modified partial least squares procedure. Calibrations developed with the MMS1 were superior to those developed using the S2000 (e.g. coefficient of correlation of 0.90 and 0.62, and standard error of cross-validation of 1.9 and 5.4%, respectively), indicating the importance of high signal to noise ratio over wavelength resolution to calibration accuracy. The design of a bench top assembly using the MMS1 for the non-invasive assessment of mesocarp sugar content of (intact) melon fruit is reported in terms of light source and angle between detector and light source, and optimisation of math treatment (derivative condition and smoothing function).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fusarium wilt, caused by Fusarium oxysporum f. sp. cubense (Foc), is one of the most destructive diseases of banana. One potential method to manage fusarium wilt of banana is by manipulating the nutrient status in the soil. This study was conducted to determine the quality of Foc suppressive and conducive soil, the influence of soil application of silica and manure on the incidence of fusarium wilt of banana. Surveys were conducted in five banana plantations in three provinces in Indonesia: Lampung-Sumatra, West Java and Central Java. From the five locations, one location (Sala-man-Central Java) was heavily infected by Foc, another location (NTF Lampung-Sumatera) was slightly infected by Foc, while the rest (Sarampad-West Java, Talaga-West Java and GGP Lampung-Sumatra) were healthy banana plantations without Foc infection. Labile carbon analysis showed that the Foc suppressive soil had greater labile carbon content than conducive soil. Also, the analysis of fluorescein diacetate hydrolysis (FDA) and ?-glucosidase showed greater microbial activity in suppressive soil than the conducive soil. Observations of the incidence of necrotic rhizome of Foc susceptible 'Ambon Kuning' (AAA) banana cultivar showed that in the suppressive soil taken from Sarampad West Java, the application of silica and manure helped suppress fusarium wilt disease development. In the conducive soil taken from Salaman-Central Java, silica and manure applications were not able to suppress disease incidence. The result of this study indicated that in suppressive soil, the application of silica can increase plant resistance to Foc infection, while manure application can increase soil microbial activity, and suppress Foc development.