13 resultados para Guthrie, Janet , 1938 -

em eResearch Archive - Queensland Department of Agriculture


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Petrifilm(R) (6410) was used directly on lamb carcasses to enumerate coliforms. 10 sites on 30 carcasses were sampled at each of 4 separate meat processing establishments (works). Coliform counts obtained by this technique were statistically analysed using analysis of variance (ANOVA) to select the optimum sampling sites on the carcass and to assess contamination of the carcass by gut flora at a particular establishment. There was a large variation between sites and between works. In general, works 3 and 4 produced cleaner carcasses than works 2, which in turn was cleaner than works 1. Works 1, 2 and 4 used conventional dressing techniques and works 3 used the inverted dressing method, therefore, the coliform counts found at works 3 and 4 are achievable regardless of dressing technique. Coliform bacteria were most concentrated around the posterior pelvic rim and less prevalent at the carcass extremities. The posterior pelvic rim (sites 3 and 4) had higher (P < 0.05) coliform counts than the exterior ventral flank area (sites 5, 6, 7 and 8), which in turn had higher (P < 0.05) counts than the proximal hind and proximal fore limbs (sites 1, 2, 9 and 10) across all works. With in-line routine testing it is recommended that the majority of carcasses sampled should give coliform counts of <50 cfu/20 cm2 for sites 4 and 8. Reprinted with permission from Journal of Food Protection. Copyright held by the International Association of Food Protection, Des Moines, Iowa, USA. Authors affifiation. J.A.Guthrie & K.J.Dunlop International Food Institute of Queensland, Department of Primary Industries, Rockhampton and G.A.Saunders Veterinary Public Health Division, Livestock and Meat Authority of Queensland, Emerald.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aims of this investigation were to enumerate coliforms in fresh mangoes, puree, cheeks, and cheeks-in-puree in order to determine the source of these organisms in the processed products, to determine methods for their control, and to identify coliforms isolated from cheeks-in-puree to determine whether they have any public health significance. Product from four processors was tested on two occasions. The retail packs of cheeks-in-puree having the highest coliform counts were those in which raw puree was added to the cheeks. Coliform counts in these samples ranged between 1.4 × 103 and 5.4 × 104 cfu/g. Pasteurisation reduced the coliform count of raw puree to < 5 cfu/g. Forty-seven percent of the 73 colonies, isolated as coliforms on the basis of their colony morphology on violet red bile agar, were identified as Klebsiella pneumoniae using the ATB 32E Identification System. Klebsiella strains were tested for growth at 10 °C, faecal coliform response, and fermentation of -melizitose, to differentiate the three phenotypically similar strains, K. pneumoniae, K. terrigena and K planticola. Results indicated that 41% of K. pneumoniae isolates gave reactions typical of K. pneumoniae. A further 44% of strains gave an atypical reaction pattern for these tests and were designated ‘psychrotrophic’ K. pneumoniae. Klebsiella pneumoniae counts of between 2.1 × 103 and 4.9 × 104 cfu/g were predicted to occur in the retail packs of mango cheeks-in-puree produced by the processors who constituted this product with raw puree. In view of the opportunistic pathogenic nature of K. pneumoniae, its presence in these products is considered undesirable and steps, such as pasteurisation of puree, should be taken in order to inactivate it

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent decreases in costs, and improvements in performance, of silicon array detectors open a range of potential applications of relevance to plant physiologists, associated with spectral analysis in the visible and short-wave near infra-red (far-red) spectrum. The performance characteristics of three commercially available ‘miniature’ spectrometers based on silicon array detectors operating in the 650–1050-nm spectral region (MMS1 from Zeiss, S2000 from Ocean Optics, and FICS from Oriel, operated with a Larry detector) were compared with respect to the application of non-invasive prediction of sugar content of fruit using near infra-red spectroscopy (NIRS). The FICS–Larry gave the best wavelength resolution; however, the narrow slit and small pixel size of the charge-coupled device detector resulted in a very low sensitivity, and this instrumentation was not considered further. Wavelength resolution was poor with the MMS1 relative to the S2000 (e.g. full width at half maximum of the 912 nm Hg peak, 13 and 2 nm for the MMS1 and S2000, respectively), but the large pixel height of the array used in the MMS1 gave it sensitivity comparable to the S2000. The signal-to-signal standard error ratio of spectra was greater by an order of magnitude with the MMS1, relative to the S2000, at both near saturation and low light levels. Calibrations were developed using reflectance spectra of filter paper soaked in range of concentrations (0–20% w/v) of sucrose, using a modified partial least squares procedure. Calibrations developed with the MMS1 were superior to those developed using the S2000 (e.g. coefficient of correlation of 0.90 and 0.62, and standard error of cross-validation of 1.9 and 5.4%, respectively), indicating the importance of high signal to noise ratio over wavelength resolution to calibration accuracy. The design of a bench top assembly using the MMS1 for the non-invasive assessment of mesocarp sugar content of (intact) melon fruit is reported in terms of light source and angle between detector and light source, and optimisation of math treatment (derivative condition and smoothing function).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Brix content of pineapple fruit can be non-invasively predicted from the second derivative of near infrared reflectance spectra. Correlations obtained using a NIRSystems 6500 spectrophotometer through multiple linear regression and modified partial least squares analyses using a post-dispersive configuration were comparable with that from a pre-dispersive configuration in terms of accuracy (e.g. coefficient of determination, R2, 0.73; standard error of cross validation, SECV, 1.01°Brix). The effective depth of sample assessed was slightly greater using the post-dispersive technique (about 20 mm for pineapple fruit), as expected in relation to the higher incident light intensity, relative to the pre-dispersive configuration. The effect of such environmental variables as temperature, humidity and external light, and instrumental variables such as the number of scans averaged to form a spectrum, were considered with respect to the accuracy and precision of the measurement of absorbance at 876 nm, as a key term in the calibration for Brix, and predicted Brix. The application of post-dispersive near infrared technology to in-line assessment of intact fruit in a packing shed environment is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential of near infra-red (NIR) spectroscopy for non-invasive measurement of fruit quality of pineapple (Ananas comosus var. Smooth Cayenne) and mango (Magnifera indica var. Kensington) fruit was assessed. A remote reflectance fibre optic probe, placed in contact with the fruit skin surface in a light-proof box, was used to deliver monochromatic light to the fruit, and to collect NIR reflectance spectra (760–2500 nm). The probe illuminated and collected reflected radiation from an area of about 16 cm2. The NIR spectral attributes were correlated with pineapple juice Brix and with mango flesh dry matter (DM) measured from fruit flesh directly underlying the scanned area. The highest correlations for both fruit were found using the second derivative of the spectra (d2 log 1/R) and an additive calibration equation. Multiple linear regression (MLR) on pineapple fruit spectra (n = 85) gave a calibration equation using d2 log 1/R at wavelengths of 866, 760, 1232 and 832 nm with a multiple coefficient of determination (R2) of 0.75, and a standard error of calibration (SEC) of 1.21 °Brix. Modified partial least squares (MPLS) regression analysis yielded a calibration equation with R2 = 0.91, SEC = 0.69, and a standard error of cross validation (SECV) of 1.09 oBrix. For mango, MLR gave a calibration equation using d2 log 1/R at 904, 872, 1660 and 1516 nm with R2 = 0.90, and SEC = 0.85% DM and a bias of 0.39. Using MPLS analysis, a calibration equation with R2 = 0.98, SEC = 0.54 and SECV = 1.19 was obtained. We conclude that NIR technology offers the potential to assess fruit sweetness in intact whole pineapple and DM in mango fruit, respectively, to within 1° Brix and 1% DM, and could be used for the grading of fruit in fruit packing sheds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The soluble solids content of intact fruit can be measured non-invasively by near infrared spectroscopy, allowing “sweetness” grading of individual fruit. However, little information is available in the literature with respect to the robustness of such calibrations. We developed calibrations based on a restricted wavelength range (700–1100 nm), suitable for use with low-cost silicon detector systems, using a stepwise multiple linear regression routine. Calibrations for total soluble solids (°Brix) in intact pineapple fruit were not transferable between summer and winter growing seasons. A combined calibration (data of three harvest dates) validated reasonably well against a population set drawn from all harvest dates (r2 = 0.72, SEP = 1.84 °Brix). Calibrations for Brix in melon were transferable between two of the three varieties examined. However, a lack of robustness of calibration was indicated by poor validation within populations of fruit harvested at different times. Further work is planned to investigate the robustness of calibration across varieties, growing districts and seasons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spectral data were collected of intact and ground kernels using 3 instruments (using Si-PbS, Si, and InGaAs detectors), operating over different areas of the spectrum (between 400 and 2500 nm) and employing transmittance, interactance, and reflectance sample presentation strategies. Kernels were assessed on the basis of oil and water content, and with respect to the defect categories of insect damage, rancidity, discoloration, mould growth, germination, and decomposition. Predictive model performance statistics for oil content models were acceptable on all instruments (R2 > 0.98; RMSECV < 2.5%, which is similar to reference analysis error), although that for the instrument employing reflectance optics was inferior to models developed for the instruments employing transmission optics. The spectral positions for calibration coefficients were consistent with absorbance due to the third overtones of CH2 stretching. Calibration models for moisture content in ground samples were acceptable on all instruments (R2 > 0.97; RMSECV < 0.2%), whereas calibration models for intact kernels were relatively poor. Calibration coefficients were more highly weighted around 1360, 740 and 840 nm, consistent with absorbance due to overtones of O-H stretching and combination. Intact kernels with brown centres or rancidity could be discriminated from each other and from sound kernels using principal component analysis. Part kernels affected by insect damage, discoloration, mould growth, germination, and decomposition could be discriminated from sound kernels. However, discrimination among these defect categories was not distinct and could not be validated on an independent set. It is concluded that there is good potential for a low cost Si photodiode array instrument to be employed to identify some quality defects of intact macadamia kernels and to quantify oil and moisture content of kernels in the process laboratory and for oil content in-line. Further work is required to examine the robustness of predictive models across different populations, including growing districts, cultivars and times of harvest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The utility of near infrared spectroscopy as a non-invasive technique for the assessment of internal eating quality parameters of mandarin fruit (Citrus reticulata cv. Imperial) was assessed. The calibration procedure for the attributes of TSS (total soluble solids) and DM (dry matter) was optimised with respect to a reference sampling technique, scan averaging, spectral window, data pre-treatment (in terms of derivative treatment and scatter correction routine) and regression procedure. The recommended procedure involved sampling of an equatorial position on the fruit with 1 scan per spectrum, and modified partial least squares model development on a 720–950-nm window, pre-treated as first derivative absorbance data (gap size of 4 data points) with standard normal variance and detrend scatter correction. Calibration model performance for the attributes of TSS and DM content was encouraging (typical Rc2 of >0.75 and 0.90, respectively; typical root mean squared standard error of calibration of <0.4 and 0.6%, respectively), whereas that for juiciness and total acidity was unacceptable. The robustness of the TSS and DM calibrations across new populations of fruit is documented in a companion study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The robustness of multivariate calibration models, based on near infrared spectroscopy, for the assessment of total soluble solids (TSS) and dry matter (DM) of intact mandarin fruit (Citrus reticulata cv. Imperial) was assessed. TSS calibration model performance was validated in terms of prediction of populations of fruit not in the original population (different harvest days from a single tree, different harvest localities, different harvest seasons). Of these, calibration performance was most affected by validation across seasons (signal to noise statistic on root mean squared error of prediction of 3.8, compared with 20 and 13 for locality and harvest day, respectively). Procedures for sample selection from the validation population for addition to the calibration population (‘model updating’) were considered for both TSS and DM models. Random selection from the validation group worked as well as more sophisticated selection procedures, with approximately 20 samples required. Models that were developed using samples at a range of temperatures were robust in validation for TSS and DM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Predictive models based on near infra-red spectroscopy for the assessment of fruit internal quality attributes must exhibit a degree of robustness across the parameters of variety, district and time to be of practical use in fruit grading. At the time this thesis was initiated, while there were a number of published reports on the development of near infra-red based calibration models for the assessment of internal quality attributes of intact fruit, there were no reports of the reliability ("robustness") of such models across time, cultivars or growing regions. As existing published reports varied in instrumentation employed, a re-analysis of existing data was not possible. An instrument platform, based on partial transmittance optics, a halogen light source and (Zeiss MMS 1) detector operating in the short wavelength near infra-red region was developed for use in the assessment of intact fruit. This platform was used to assess populations of macadamia kernels, melons and mandarin fruit for total soluble solids, dry matter and oil concentration. Calibration procedures were optimised and robustness assessed across growing areas, time of harvest, season and variety. In general, global modified partial least squares regression (MPLS) calibration models based on derivatised absorbance data were better than either multiple linear regression or `local' MPLS models in the prediction of independent validation populations . Robustness was most affected by growing season, relative to the growing district or variety . Various calibration updating procedures were evaluated in terms of calibration robustness. Random selection of samples from the validation population for addition to the calibration population was equivalent to or better than other methods of sample addition (methods based on the Mahalanobis distance of samples from either the centroid of the population or neighbourhood samples). In these exercises the global Mahalanobis distance (GH) was calculated using the scores and loadings from the calibration population on the independent validation population. In practice, it is recommended that model predictive performance be monitored in terms of predicted sample GH, with model updating using as few as 10 samples from the new population undertaken when the average GH value exceeds 1 .0 .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Near infrared spectroscopy (NIRS) can be used for the on-line, non-invasive assessment of fruit for eating quality attributes such as total soluble solids (TSS). The robustness of multivariate calibration models, based on NIRS in a partial transmittance optical geometry, for the assessment of TSS of intact rockmelons (Cucumis melo) was assessed. The mesocarp TSS was highest around the fruit equator and increased towards the seed cavity. Inner mesocarp TSS levels decreased towards both the proximal and distal ends of the fruit, but more so towards the proximal end. The equatorial region of the fruit was chosen as representative of the fruit for near infrared assessment of TSS. The spectral window for model development was optimised at 695-1045 nm, and the data pre-treatment procedure was optimised to second-derivative absorbance without scatter correction. The 'global' modified partial least squares (MPLS) regression modelling procedure of WINISI (ver. 1.04) was found to be superior with respect to root mean squared error of prediction (RMSEP) and bias for model predictions of TSS across seasons, compared with the 'local' MPLS regression procedure. Updating of the model with samples selected randomly from the independent validation population demonstrated improvement in both RMSEP and bias with addition of approximately 15 samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Partial least squares regression models on NIR spectra are often optimised (for wavelength range, mathematical pretreatment and outlier elimination) in terms of calibration terms of validation performance with reference to totally independent populations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phytophthora root rot (PRR), caused by P. cinnamomi, is a primary constraint on avocado productivity in Australia. Numerous field trials at sites in northern NSW and southern QLD have demonstrated significant variation in tree health amongst commercial rootstocks and recently selected material, grown under high PRR disease pressure. Selections 'SHSR-02', 'SHSR-04', ungrafted 'Hass' (rooted cuttings from clonal propagation) and the commercial rootstock 'DusaTM' were significantly healthier over time than other rootstocks, many of which died during the course of the trials. 'Reed' was consistently highly susceptible. In many cases superior tree health was associated with increased tree height and trunk girth. The trials also clearly demonstrate the negative impact of Phytophthora root rot on establishment of new avocado production blocks, and the importance of identifying and selecting avocado rootstock material that can withstand high P. cinnamomi disease pressure.