3 resultados para Alternative construction method

em eResearch Archive - Queensland Department of Agriculture


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Weighing lysimeters are the standard method for directly measuring evapotranspiration (ET). This paper discusses the construction, installation, and performance of two (1.52 m × 1.52 m × 2.13-m deep) repacked weighing lysimeters for measuring ET of corn and soybean in West Central Nebraska. The cost of constructing and installing each lysimeter was approximately US $12,500, which could vary depending on the availability and cost of equipment and labor. The resolution of the lysimeters was 0.0001 mV V-1, which was limited by the data processing and storage resolution of the datalogger. This resolution was equivalent to 0.064 and 0.078 mm of ET for the north and south lysimeters, respectively. Since the percent measurement error decreases with the magnitude of the ET measured, this resolution is adequate for measuring ET for daily and longer periods, but not for shorter time steps. This resolution would result in measurement errors of less than 5% for measuring ET values of ≥3 mm, but the percent error rapidly increases for lower ET values. The resolution of the lysimeters could potentially be improved by choosing a datalogger that could process and store data with a higher resolution than the one used in this study.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A restriction analysis of PCR (PCR-REA) amplified apxIVA gene has been suggested as an alternative method for serotyping of Actinobacillus pleuropneumoniae by Jaglic et al. [Jaglic, Z., Svastova, P., Rychlik, I., Nedbalcova, K., Kucerova, Z., Pavlik, I., Bartos, M., 2004. Differentiation of Actinobacillus pleuropneumoniae by PCR-REA based on sequence variability of the apxIVA gene and by ribotyping. Vet. Microbiol. 103, 63-69]. The current study investigated whether this alternative method could distinguish between the reference strains of serovars 13-15 and the value of the method when applied to 47 field isolates representing serovars 1-3, 5, 7-9, 12 and 15 as well as non-typable isolates. The reference strains of serovars 13 and 14 had the same sized product after the apxIVA PCR, while the product for serovar 15 was of different size compared to all the other serovar reference strains. The CfoI digest profiles of the reference serovars 13 and 14 strains were different from each other and from all other serovars. The HpaII digest profiles of these two serovars were very similar to each other, but both were distinctively different from the other serovar profiles. The CfoI digest profile of serovar 15 strain was very similar to the serovars 3 and 12 strains except for two faint extra bands for serovar 15. The HpaII digest profiles of serovars 12 and 15 reference strains were identical. The PCR-REA method correctly recognized the serovar of 21 of 43 field isolates. It was concluded that the method was a useful additional tool to support, but could not replace, conventional serotyping.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Industry acceptance of alternative sulphite treatments for preventing blackspot in prawns is limited. This study demonstrated that dipping prawns (Penaeus monodon and Fenneropenaeus merguiensis) in a less concentrated solution for longer times provides better control of blackspot formation than the recommended 2 minute dip in 50 mg/L 4-hexylresorcinol. Protection improved as modified dipping times and solution concentrations increased. Blackspot protection provided by most of the modified dip methods was more effective than a 1 minute dip in 1% sodium metabisulphite. The recommended 2 minute dip method should be limited to 125 kg when used on consecutive 25-kg batches of prawns. Yields increased by less than 10% even after 72-hour exposure in the modified dip. The new dipping method meets most international residue standards when applying the modified treatments evaluated.