3 resultados para 1995_12110742 Optics-13

em eResearch Archive - Queensland Department of Agriculture


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent decreases in costs, and improvements in performance, of silicon array detectors open a range of potential applications of relevance to plant physiologists, associated with spectral analysis in the visible and short-wave near infra-red (far-red) spectrum. The performance characteristics of three commercially available ‘miniature’ spectrometers based on silicon array detectors operating in the 650–1050-nm spectral region (MMS1 from Zeiss, S2000 from Ocean Optics, and FICS from Oriel, operated with a Larry detector) were compared with respect to the application of non-invasive prediction of sugar content of fruit using near infra-red spectroscopy (NIRS). The FICS–Larry gave the best wavelength resolution; however, the narrow slit and small pixel size of the charge-coupled device detector resulted in a very low sensitivity, and this instrumentation was not considered further. Wavelength resolution was poor with the MMS1 relative to the S2000 (e.g. full width at half maximum of the 912 nm Hg peak, 13 and 2 nm for the MMS1 and S2000, respectively), but the large pixel height of the array used in the MMS1 gave it sensitivity comparable to the S2000. The signal-to-signal standard error ratio of spectra was greater by an order of magnitude with the MMS1, relative to the S2000, at both near saturation and low light levels. Calibrations were developed using reflectance spectra of filter paper soaked in range of concentrations (0–20% w/v) of sucrose, using a modified partial least squares procedure. Calibrations developed with the MMS1 were superior to those developed using the S2000 (e.g. coefficient of correlation of 0.90 and 0.62, and standard error of cross-validation of 1.9 and 5.4%, respectively), indicating the importance of high signal to noise ratio over wavelength resolution to calibration accuracy. The design of a bench top assembly using the MMS1 for the non-invasive assessment of mesocarp sugar content of (intact) melon fruit is reported in terms of light source and angle between detector and light source, and optimisation of math treatment (derivative condition and smoothing function).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To assist in the development of safe piggery effluent re-use guidelines by determining the level of selected pathogens and indicator organisms in the effluent ponds of 13 south-east Queensland piggeries. Methods and Results: The numbers of thermotolerant coliforms, Campylobacter jejuni/coli, Erysipelothrix rhusiopathiae, Escherichia coli, Salmonella and rotavirus were determined in 29 samples derived from the 13 piggeries. The study demonstrated that the 13 final effluent ponds contained an average of 1Æ2 · 105 colony-forming units (CFU) 100 ml)1 of thermotolerant coliforms and 1Æ03 · 105 CFU 100 ml)1 of E. coli. The Campylobacter level varied from none detectable (two of 13 piggeries) to a maximum of 930 most probable number (MPN) 100 ml)1 (two of 13 piggeries). Salmonella was detected in the final ponds of only four of the 13 piggeries and then only at a low level (highest level being 51 MPN 100 ml)1). No rotavirus and no Erysip. rhusiopathiae were detected. The average log10 reductions across the ponding systems to the final irrigation pond were 1Æ77 for thermotolerant coliforms, 1Æ71 for E. coli and 1Æ04 for Campylobacter. Conclusions: This study has provided a baseline knowledge on the levels of indicator organisms and selected pathogens in piggery effluent. Significance and Impact of the Study: The knowledge gained in this study will assist in the development of guidelines to ensure the safe and sustainable re-use of piggery effluent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

General Index Vol 13 Parts 1-6, pages 1-81