3 resultados para metrological reliability

em Universidade Complutense de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to analyze the internal consistency and the external and structure validity of the 12-Item General Health Questionnaire (GHQ-12) in the Spanish general population. A stratified sample of 1001 subjects, ages between 25 and 65 years, taken from the general Spanish population was employed. The GHQ-12 and the Inventory of Situations and Responses of Anxiety-ISRA were administered. A Cronbach’s alpha of .76 (Standardized Alpha: .78) and a 3-factor structure (with oblique rotation and maximum likelihood procedure) were obtained. External validity of Factor I (Successful Coping) with the ISRA is very robust (.82; Factor II, .70; Factor III, .75). The GHQ-12 shows adequate reliability and validity in the Spanish population. Therefore, the GHQ-12 can be used with efficacy to assess people’s overall psychological well-being and to detect non-psychotic psychiatric problems. Additionally, our results confirm that the GHQ-12 can best be thought of as a multidimensional scale that assesses several distinct aspects of distress, rather than just a unitary screening measure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Cronbach's alpha is the most widely used method for estimating internal consistency reliability. This procedure has proved very resistant to the passage of time, even if its limitations are well documented and although there are better options as omega coefficient or the different versions of glb, with obvious advantages especially for applied research in which the ítems differ in quality or have skewed distributions. In this paper, using Monte Carlo simulation, the performance of these reliability coefficients under a one-dimensional model is evaluated in terms of skewness and no tau-equivalence. The results show that omega coefficient is always better choice than alpha and in the presence of skew items is preferable to use omega and glb coefficients even in small samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several studies have reported changes in spontaneous brain rhythms that could be used asclinical biomarkers or in the evaluation of neuropsychological and drug treatments in longitudinal studies using magnetoencephalography (MEG). There is an increasing necessity to use these measures in early diagnosis and pathology progression; however, there is a lack of studies addressing how reliable they are. Here, we provide the first test-retest reliability estimate of MEG power in resting-state at sensor and source space. In this study, we recorded 3 sessions of resting-state MEG activity from 24 healthy subjects with an interval of a week between each session. Power values were estimated at sensor and source space with beamforming for classical frequency bands: delta (2–4 Hz), theta (4–8 Hz), alpha (8–13 Hz), low beta (13–20 Hz), high beta (20–30 Hz), and gamma (30–45 Hz). Then, test-retest reliability was evaluated using the intraclass correlation coefficient (ICC). We also evaluated the relation between source power and the within-subject variability. In general, ICC of theta, alpha, and low beta power was fairly high (ICC > 0.6) while in delta and gamma power was lower. In source space, fronto-posterior alpha, frontal beta, and medial temporal theta showed the most reliable profiles. Signal-to-noise ratio could be partially responsible for reliability as low signal intensity resulted inhigh within-subject variability, but also the inherent nature of some brain rhythms in resting-state might be driving these reliability patterns. In conclusion, our results described the reliability of MEG power estimates in each frequency band, which could be considered in disease characterization or clinical trials.