5 resultados para PN

em Universidade Complutense de Madrid


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The azimuthal asymmetry in the risetime of signals in Auger surface detector stations is a source of information on shower development. The azimuthal asymmetry is due to a combination of the longitudinal evolution of the shower and geometrical effects related to the angles of incidence of the particles into the detectors. The magnitude of the effect depends upon the zenith angle and state of development of the shower and thus provides a novel observable, (sec theta)(max), sensitive to the mass composition of cosmic rays above 3 x 10(18) eV. By comparing measurements with predictions from shower simulations, we find for both of our adopted models of hadronic physics (QGSJETII-04 and EPOS-LHC) an indication that the mean cosmic-ray mass increases slowly with energy, as has been inferred from other studies. However, the mass estimates are dependent on the shower model and on the range of distance from the shower core selected. Thus the method has uncovered further deficiencies in our understanding of shower modeling that must be resolved before the mass composition can be inferred from (sec theta)(max).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para comparar la eficacia para dejar de fumar de la terapia cognitiva conductual intensiva (TCC/I), la TCC/I con parches de nicotina (TCC/I+PN) y la terapia cognitiva conductual no intensiva con parches de nicotina (TCC/NI+PN) se realizó un estudio experimental de medidas repetidas con 235 fumadores adultos asignados aleatoriamente a uno de esos tres tratamientos. Entre los pacientes que completaron el tratamiento (n = 152) la TCC/I+PN mostró tasas de abstinencia a los 6 meses y al año, mayores que la TCC/NI+PN, mientras que la TCC/I mostró tasas de abstinencia que no eran significativamente diferentes de las de los otros dos tratamientos. Estos resultados sugieren que los parches de nicotina se deberían utilizar siempre con una terapia cognitiva conductual lo más intensiva posible y que la utilización de esta última terapia en solitario debería gozar de mayor relevancia en las guías clínicas para dejar de fumar.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Las redes de Petri son un lenguaje formal muy adecuado para la modelizacíon, ańalisis y verificacíon de sistemas concurrentes con infinitos estados. En particular, son muy apropiadas para estudiar las propiedades de seguridad de dichos sistemas, dadas sus buenas propiedades de decidibilidad. Sin embargo, en muchas ocasiones las redes de Petri carecen de la expresividad necesaria para representar algunas caracteŕısticas fundamentales de los sistemas que se manejan hoy en d́ıa, como el manejo de tiempo real, costes reales, o la presencia de varios procesos con un ńumero no acotado de estados ejecut́andose en paralelo. En la literatura se han definido y estudiado algunas extensiones de las redes de Petri para la representaci ́on de las caracteŕısticas anteriores. Por ejemplo, las “Redes de Petri Temporizadas” [83, 10](TPN) incluyen el manejo de tiempo real y las ν-redes de Petri [78](ν-PN) son capaces de representar un ńumero no acotado de procesos con infinitos estados ejecut́andose concurrentemente. En esta tesis definimos varias extensiones que réunen estas dos caracteŕısticas y estudiamos sus propiedades de decidibilidad. En primer lugar definimos las “ν-Redes de Petri Temporizadas”, que réunen las caracteŕısticas expresivas de las TPN y las ν-PN. Este nuevo modelo es capaz de representar sistemas con un ńumero no acotado de procesos o instancias, donde cada proceso es representado por un nombre diferente, y tiene un ńumero no acotado de relojes reales. En este modelo un reloj de una instancia debe satisfacer ciertas condiciones (pertenecer a un intervalo dado) para formar parte en el disparo de una transicíon. Desafortunadamente, demostramos que la verificacíon de propiedades de seguridad es indecidible para este modelo...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30-80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy-corrected for geometrical effects-is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 +/- 0.7 (stat) +/- 6.7 (syst) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principles calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.