3 resultados para Induced air
em Universidade Complutense de Madrid
Resumo:
Electromagnetic energy injected into the universe above a few hundred TeV is expected to pile up as γ radiation in a relatively narrow energy interval below 100 TeV due to its interaction with the 2.7^°K background radiation. We present an upper limit (90% C.L.) on the ratio of primary γ to charged cosmic rays in the energy interval 65–160 TeV (80–200 TeV) of 10.3 • 10^−3 (7.8 • 10^−3). Data from the HEGRA cosmic-ray detector complex consisting of a wide angle Čerenkov array (AIROBICC) measuring the lateral distribution of air Čerenkov light and a scintillator array, were used with a novel method to discriminate γ-ray and hadron induced air showers. If the presently unmeasured universal far infrared background radiation is not too intense, the result rules out a topological-defect origin of ultrahigh energy cosmic rays for masses of the X particle released by the defects equal to or larger than about 10^16 GeV.
Resumo:
We describe the measurement of the depth of maximum, X-max, of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10(18) eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are selected for the analysis. The average shower maximum was found to evolve with energy at a rate of (106 +/- 35-21) g/cm(2)/decade below 10(18.24) +/- (0.05) eV, and d24 +/- 3 g/cm(2)/ecade above this energy. The measured shower-to-shower fluctuations decrease from about 55 to 26 g/cm(2). The interpretation of these results in terms of the cosmic ray mass composition is briefly discussed.
Resumo:
Purpose. To measure the increase in tear secretion evoked by selective stimulation of the different populations of sensory receptors of the cornea and conjunctiva by using moderate and intense mechanical, chemical, and cold stimuli. Methods. Six healthy subjects participated in the study. Tear secretion was measured in both eyes by the Schirmer’s test conducted under control conditions and after stimulation of the center of the cornea and the temporal conjunctiva with a gas esthesiometer. Mechanical stimulation consisted in three pulses of 3 seconds’ duration of warmed air (at 34°C on the eye surface) applied at moderate (170 mL/min) and high (260 mL/min) flow rates. Cold thermal stimulation was made with cooled air that produced a corneal temperature drop of −1°C or −4.5°C. Chemical (acidic) stimulation was performed with a jet of gas containing a mixture of 80% CO2 in air. Results. The basal volume of tear secretion increased significantly (P < 0.05, paired t-test) after stimulation of the cornea with high-flow mechanical stimuli (260 mL/min), intense cooling pulses (−4.5°C), and chemical stimulation (80% CO2). The same stimuli were ineffective when applied to the conjunctiva. Moderate mechanical (170 mL/min) and cold (−1°C) stimulation of the cornea or the conjunctiva did not change significantly the volume of tear secretion. Conclusions. Reflex tear secretion caused by corneal stimulation seems to be chiefly due to activation of corneal polymodal nociceptors, whereas selective excitation of corneal mechanonociceptors or cold receptors appears to be less effective in evoking an augmented lacrimal secretion. Conjunctival receptors stimulated at equivalent levels do not evoke an increased tear secretion.