2 resultados para EMBRYO IMPLANTATION

em Universidade Complutense de Madrid


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ontogenic development of the sphincter iris has been studied by immunocytochemistry and standard staining on chick embryos from stage 25 HH to the time of hatching. We have used the monoclonal antibody 13F4, a highly specific marker of muscular cells. We have observed three different regions in the iris. Tn the pupillary region, immunoreactive cells are in continuous contact with the inner epithelium of the pupillary margin. In the intermediate region, the outer epithelium forms buds of pigmented cells that emigrate toward the stroma. In this epithelium cells that are totally or partially unpigmented exist, and they are 13F4 positive. In the sphincter we have observed 13F4 positive cells with melanin granules. In the ciliary region, the immunoreactivity appears in dispersed mesenchymal cells. The present findings are consistent with a triple origin of the sphincter iris in the chick embryo. This muscle is derived from the inner epithelium of the pupillary margin, the intermediate region of the outer epithelium, and from the mesenchymal cells. The cells of the inner epithelium of the pupillary margin are differentiated into smooth muscle cells, and the remaining cells form striated muscle cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.