5 resultados para CATARACT-SURGERY

em Universidade Complutense de Madrid


Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To compare disk halo size in response to a glare source in eyes with an aspheric apodized diffractive multifocal intraocular lens (IOL) or aspheric monofocal IOL. SETTING: Rementeria Ophthalmological Clinic, Madrid, Spain. DESIGN: Prospective randomized masked study. METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in eyes that had cataract surgery and bilateral implantion of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were recorded. Monocular uncorrected distance visual acutity (UDVA) and corrected distance visual acuity (CDVA) were measured using high-contrast (96%) and low-contrast (10%) logMAR letter charts. RESULTS: The study comprised 39 eyes of 39 subjects (aged 70 to 80 years); 21 eyes had a multifocal IOL and 18 eyes a monofocal IOL. The mean halo radius was 35 arcmin larger in the multifocal IOL group than the monofocal group (P<.05). Greater halo effects were reported in the multifocal IOL group (P<.05). The mean monocular high-contrast UDVA and low-contrast UDVA did not vary significantly between groups, whereas the mean monocular high-contrast CDVA and low-contrast CDVA were significantly worse at 0.12 logMAR and 0.13 logMAR in the multifocal than in the monofocal IOL group, respectively (P <.01). A significant positive correlation was detected by multiple linear regression between the halo radius and low-contrast UDVA in the multifocal IOL group (r = 0.72, P<.001). CONCLUSIONS: The diffractive multifocal IOL gave rise to a larger disk halo size, which was correlated with a worse low-contrast UDVA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To compare visual outcomes, rotational stability, and centration in a randomized controlled trial in patients undergoing cataract surgery who were bilaterally implanted with two different trifocal intraocular lenses (IOLs) with a similar optical zone but different haptic shape. METHODS: Twenty-one patients (42 eyes) with cataract and less than 1.50 D of corneal astigmatism underwent implantation of one FineVision/MicoF IOL in one eye and one POD FineVision IOL in the contralateral eye (PhysIOL, Liège, Belgium) at IOA Madrid Innova Ocular, Madrid, Spain. IOL allocation was random. Outcome measures, all evaluated 3 months postoperatively, included monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), distance-corrected intermediate (DCIVA), and near (DCNVA) visual acuity (at 80, 40, and 25 cm) under photopic conditions, refraction, IOL centration, haptic rotation, dysphotopsia, objective quality of vision and aberration quantification, patient satisfaction, and spectacle independence. RESULTS: Three months postoperatively, mean monocular UDVA, CDVA, DCIVA, and DCNVA (40 cm) under photopic conditions were 0.04 ± 0.07, 0.01 ± 0.04, 0.15 ± 0.11, and 0.16 ± 0.08 logMAR for the eyes implanted with the POD FineVision IOL and 0.03 ± 0.05, 0.01 ± 0.02, 0.17 ± 0.12, and 0.14 ± 0.08 logMAR for those receiving the FineVision/MicroF IOL. Moreover, the POD FineVision IOL showed similar centration (P > .05) and better rotational stability (P < .05) than the FineVision/MicroF IOL. Regarding halos, there was a minimal but statistically significant difference, obtaining better results with FineVision/MicroF. Full spectacle independence was reported by all patients. CONCLUSIONS: This study revealed similar visual outcomes for both trifocal IOLs under test (POD FineVision and FineVision/MicroF). However, the POD FineVision IOL showed better rotational stability, as afforded by its design.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: to determine whether pupil dilation affects biometric measurements and intraocular lens (IOL) power calculation made using the new swept-source optical coherence tomography-based optical biometer (IOLMaster 700©; Carl Zeiss Meditec, Jena, Germany). Procedures: eighty-one eyes of 81 patients evaluated for cataract surgery were prospectively examined using the IOLMaster 700© before and after pupil dilation with tropicamide 1%. The measurements made were: axial length (AL), central corneal thickness (CCT), aqueous chamber depth (ACD), lens thickness (LT), mean keratometry (MK), white-to-white distance (WTW) and pupil diameter (PD). Holladay II and SRK/T formulas were used to calculate IOL power. Agreement between measurement modes (with and without dilation) was assessed through intraclass correlation coefficients (ICC) and Bland-Altman plots. Results: mean patient age was 75.17 ± 7.54 years (range: 57–92). Of the variables determined, CCT, ACD, LT and WTW varied significantly according to pupil dilation. Excellent intraobserver correlation was observed between measurements made before and after pupil dilation. Mean IOL power calculation using the Holladay 2 and SRK/T formulas were unmodified by pupil dilation. Conclusions: the use of pupil dilation produces statistical yet not clinically significant differences in some IOLMaster 700© measurements. However, it does not affect mean IOL power calculation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose To compare measurements taken using a swept-source optical coherence tomography-based optical biometer (IOLmaster 700) and an optical low-coherence reflectometry biometer (Lenstar 900), and to determine the clinical impacts of differences in their measurements on intraocular lens (IOL) power predictions. Methods Eighty eyes of 80 patients scheduled to undergo cataract surgery were examined with both biometers. The measurements made using each device were axial length (AL), central corneal thickness (CCT), aqueous depth (AQD), lens thickness (LT), mean keratometry (MK), white-to-white distance (WTW), and pupil diameter (PD). Holladay 2 and SRK/T formulas were used to calculate IOL power. Differences in measurement between the two biometers were determined using the paired t-test. Agreement was assessed through intraclass correlation coefficients (ICC) and Bland–Altman plots. Results Mean patient age was 76.3±6.8 years (range 59–89). Using the Lenstar, AL and PD could not be measured in 12.5 and 5.25% of eyes, respectively, while IOLMaster 700 took all measurements in all eyes. The variables CCT, AQD, LT, and MK varied significantly between the two biometers. According to ICCs, correlation between measurements made with both devices was excellent except for WTW and PD. Using the SRK/T formula, IOL power prediction based on the data from the two devices were statistically different, but differences were not clinically significant. Conclusions No clinically relevant differences were detected between the biometers in terms of their measurements and IOL power predictions. Using the IOLMaster 700, it was easier to obtain biometric measurements in eyes with less transparent ocular media or longer AL.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background In recent years new models of intraocular lenses are appearing on the market to reduce requirements for additional optical correction. The purpose of this study is to assess visual outcomes following bilateral cataract surgery and the implant of a FineVision® trifocal intraocular lens (IOL). Methods Prospective, nonrandomized, observational study. Vision was assessed in 44 eyes of 22 patients (mean age 68.4 ± 5.5 years) before and 3 months after surgery. Aberrations were determined using the Topcon KR-1 W wave-front analyzer. LogMAR visual acuity was measured at distance (corrected distance visual acuity, CDVA 4 m), intermediate (distance corrected intermediate visual acuity, DCIVA 60 cm) and near (distance corrected near visual acuity, DCNVA 40 cm). The Pelli-Robson letter chart and the CSV-1000 test were used to estimate contrast sensitivity (CS). Defocus curve testing was performed in photopic and mesopic conditions. Adverse photic phenomena were assessed using the Halo v1.0 program. Results Mean aberration values for a mesopic pupil diameter were: total HOA RMS: 0.41 ± 0.30 μm, coma: 0.32 ± 0.22 μm and spherical aberration: 0.21 ± 0.20 μm. Binocular logMAR measurements were: CDVA −0.05 ± 0.05, DCIVA 0.15 ± 0.10, and DCNVA 0.06 ± 0.10. Mean Pelli-Robson CS was 1.40 ± 0.14 log units. Mean CSV100 CS for the 4 frequencies examined (A: 3 cycles/degree (cpd), B: 6 cpd, C: 12 cpd, D: 18 cpd) were 1.64 ± 0.14, 1.77 ± 0.18, 1.44 ± 0.24 and 0.98 ± 0.24 log units, respectively. Significant differences were observed in defocus curves for photopic and mesopic conditions (p < 0.0001). A mean disturbance index of 0.28 ± 0.22 was obtained. Conclusions Bilateral FineVision IOL implant achieved a full range of adequate vision, satisfactory contrast sensitivity, and a lack of significant adverse photic phenomena. Trial registration Eudract Clinical Trials Registry Number: 2014-003266-2.