6 resultados para 1113 Ophthalmology and Optometry
em Universidade Complutense de Madrid
Resumo:
Purpose: To study the concentrations of diadenosine polyphosphates in the ocular surface after PRK and LASIK. Methods: Sixty-one patients (30 males and 31 females) with ages ranging from 20 to 63 (34.04 ± 9.13 years) were recruited in Balear Institute of Ophthalmology, Palma de Mallorca, Spain. LASIK was performed in 92 eyes of 46 patients and PRK in 25 eyes of 15 patients. Variations in the levels of diadenosine polyphosphate (Ap4A and Ap5A), Schirmer I (Jones test), TBUT, corneal staining together with the Dry Eye Questionnaire to evaluate discomfort and dryness were studied. All tests were performed at the preoperative visit and at 1-day, 2-week, 1-month and 3-month postoperative visits. Results: Ap4A showed a 5 and 3.5 fold increase at the 1-day visit for LASIK and PRK, respectively. LASIK patients continued having higher statistically significant concentrations (p = 0.01) all over the follow-up. Ap5A showed no significant differences at any visit. Tear volume decreased during the 3 months in LASIK. The PRK cases had a normal volume at 1 month. TBUT in LASIK increased at the 1-day visit (p = 0,002) and decreased from the 2 weeks onwards and for the PRK, decreased by a 35% at the 1-day visit and kept reduced for a month. Discomfort only increased at the 1-day visit (p = 0.007). Dryness frequency was similar in all visits. Conclusions: Ap4A levels only are increased in refractive surgery patients during the first day after the surgery. This increasing suggests that Ap4A may help accelerating the healing process.
Resumo:
Purpose. To investigate the role of ERK1/2 and RhoA/ROCK intracellular pathways in the modification of corneal re-epithelialization when stimulated by the diadenosine polyphosphates Ap4A and Ap3A. Methods. In wounded confluent SIRC (Statens Seruminstitut rabbit cornea) cell monolayers and in the presence or absence of Ap4A or Ap3A 100 μM, a battery of P2 receptor antagonists and inhibitors of tyrosin kinases, MAPK, and cytoskeleton pathways (AG1478 100 μM, U0126 100 μM, Y27632 100 nM, and (−)-blebbistatin 10 μM; n = 8 each) were assayed. Also, the activation of ERK1/2 and ROCK-I was examined by Western blot assay after treatment with Ap4A and Ap3A (100 μM), with or without suramin, RB-2, U0126, and Y27632. The intracellular distribution of pERK and ROCK-I was examined in the presence of Ap4A or Ap3A (100 μM) with U0126 and Y27632 (100 nM). Results. In the presence of Ap4A, U0126, Y27632, AG1478, and (−)-blebbistatin, reduced the migration rate compared to the effect of Ap4A alone (P < 0.0001, P < 0.001, P < 0.01, and P < 0.1 versus Ap4A, respectively). In the presence of Ap3A 100 μM, U0126 and Y27632 accelerated the migration rate when compared with the effect of Ap3A alone, whereas AG1478 and (−)-blebbistatin (P < 0.0001 versus Ap3A) slowed the migration rate. Western blot assays demonstrated that both dinucleotides activated the ERK1/2 pathway but only Ap4A activated the ROCK-I pathway. The intracellular distribution of pERK1/2 and ROCK-I reflected cross-talk between these two pathways. Conclusions. The activation of the Ap4A/P2Y2 receptor, accelerates corneal epithelial cell migration during wound healing with the activation of MAPK and cytoskeleton pathways, whereas activation of the Ap3A/P2Y6 receptor signals only the MAPK pathway.
Resumo:
Purpose. To measure the increase in tear secretion evoked by selective stimulation of the different populations of sensory receptors of the cornea and conjunctiva by using moderate and intense mechanical, chemical, and cold stimuli. Methods. Six healthy subjects participated in the study. Tear secretion was measured in both eyes by the Schirmer’s test conducted under control conditions and after stimulation of the center of the cornea and the temporal conjunctiva with a gas esthesiometer. Mechanical stimulation consisted in three pulses of 3 seconds’ duration of warmed air (at 34°C on the eye surface) applied at moderate (170 mL/min) and high (260 mL/min) flow rates. Cold thermal stimulation was made with cooled air that produced a corneal temperature drop of −1°C or −4.5°C. Chemical (acidic) stimulation was performed with a jet of gas containing a mixture of 80% CO2 in air. Results. The basal volume of tear secretion increased significantly (P < 0.05, paired t-test) after stimulation of the cornea with high-flow mechanical stimuli (260 mL/min), intense cooling pulses (−4.5°C), and chemical stimulation (80% CO2). The same stimuli were ineffective when applied to the conjunctiva. Moderate mechanical (170 mL/min) and cold (−1°C) stimulation of the cornea or the conjunctiva did not change significantly the volume of tear secretion. Conclusions. Reflex tear secretion caused by corneal stimulation seems to be chiefly due to activation of corneal polymodal nociceptors, whereas selective excitation of corneal mechanonociceptors or cold receptors appears to be less effective in evoking an augmented lacrimal secretion. Conjunctival receptors stimulated at equivalent levels do not evoke an increased tear secretion.
Resumo:
Purpose.: To evaluate the levels of dinucleotides diadenosine tetraphosphate (Ap4A) and diadenosine pentaphosphate (Ap5A) in tears of patients wearing rigid gas permeable (RGP) contact lenses on a daily wear basis and of patients wearing reverse-geometry RGP lenses overnight for orthokeratology treatment. Methods.: Twenty-two young volunteers (10 females, 12 males; 23.47 ± 4.49 years) were fitted with an alignment-fit RGP lens (paflufocon B) for a month, and after a 15-day washout period they were fitted with reverse-geometry RGP lenses for corneal reshaping (paflufocon D) for another month. During each period, tears were collected at baseline day 1, 7, 15, and 28. Ap4A and Ap5A were measured by high-pressure liquid chromatography (HPLC). Additionally, corneal staining, break-up time (BUT), Schirmer test, and dryness symptoms were evaluated. Results.: Ap4A concentrations increased significantly from baseline during the whole period of daily wear of RGP lenses (P < 0.001); concentration was also significantly higher than in the orthokeratology group, which remained at baseline levels during the study period except at day 1 (P < 0.001) and day 28 (P = 0.041). While BUT and Schirmer remained unchanged in both groups, discomfort and dryness were significantly increased during alignment-fit RGP daily wear but not during the orthokeratology period. Conclusions.: Daily wear of RGP lenses increased the levels of Ap4A due to mechanical stimulation by blinking of the corneal epithelium, and this is associated with discomfort. Also, orthokeratology did not produce symptoms or signs of ocular dryness, which could be a potential advantage over soft contact lenses in terms of contact lens-induced dryness.
Resumo:
·AIM: To determine the repeatability and agreement of stereoacuity measurements made using some of the most widely used clinical tests: Frisby, TNO, Randot and Titmus. ·METHODS: Stereoacuity was measured in two different sessions separated by a time interval of at least 24h but no longer than 1wk in 74 subjects of mean age 20.6y using the four methods. The study participants were divided into two groups: subjects with normal binocular vision and subjects with abnormal binocular vision. ·RESULTS: Best repeatability was shown by the Frisby and Titmus [coefficient of repeatability (COR): 依13 and 依12s arc respectively] in the subjects with normal binocular vision though a clear ceiling effect was noted. In the subjects with abnormal binocular vision, best repeatability was shown by the Frisby (COR: 依69s arc) and Randot (COR: 依72s arc). In both groups, the TNO test showed poorest agreement with the other tests. ·CONCLUSION: Therepeatabilityof stereoacuitymeasures was low in subjects with poor binocular vision yet fairly good in subjects with normal binocular vision with the exception of the TNO test. The reduced agreement detected between the tests indicates they cannot be used interchangeably.
Resumo:
Purpose: The purpose of this study was to develop and validate a multivariate predictive model to detect glaucoma by using a combination of retinal nerve fiber layer (RNFL), retinal ganglion cell-inner plexiform (GCIPL), and optic disc parameters measured using spectral-domain optical coherence tomography (OCT). Methods: Five hundred eyes from 500 participants and 187 eyes of another 187 participants were included in the study and validation groups, respectively. Patients with glaucoma were classified in five groups based on visual field damage. Sensitivity and specificity of all glaucoma OCT parameters were analyzed. Receiver operating characteristic curves (ROC) and areas under the ROC (AUC) were compared. Three predictive multivariate models (quantitative, qualitative, and combined) that used a combination of the best OCT parameters were constructed. A diagnostic calculator was created using the combined multivariate model. Results: The best AUC parameters were: inferior RNFL, average RNFL, vertical cup/disc ratio, minimal GCIPL, and inferior-temporal GCIPL. Comparisons among the parameters did not show that the GCIPL parameters were better than those of the RNFL in early and advanced glaucoma. The highest AUC was in the combined predictive model (0.937; 95% confidence interval, 0.911–0.957) and was significantly (P = 0.0001) higher than the other isolated parameters considered in early and advanced glaucoma. The validation group displayed similar results to those of the study group. Conclusions: Best GCIPL, RNFL, and optic disc parameters showed a similar ability to detect glaucoma. The combined predictive formula improved the glaucoma detection compared to the best isolated parameters evaluated. The diagnostic calculator obtained good classification from participants in both the study and validation groups.