5 resultados para visual research

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This research is focused on the contribution of area 7 to the short-term visual spatial memory. Three rhesus monkeys (Macaca mulatta) were trained in the direct delayed response task in which 5 delay intervals were used in each session. When each monkey reached the criterion of 90% correct responses in 5 successive sessions, two monkeys underwent a surgery while the other one received a sham operation as a control. In the first stage of the surgery, bilateral areas 7a, 7b and 7ip of the parietal cortex of two monkeys were precisely lesioned. After 7 days of recuperation, the monkeys were required to do the same task. The average percentage of correct responses in the lesioned animals decreased from 94.7% to 89.3% and 93.3% to 82.0% respectively (no significance, P > 0.05, n = 2). In addition, the monkeys' complex movements were mildly impaired. The lesioned monkeys were found to have difficulty picking up food from the wells. In the second stage, bilateral area 7m was lesioned. In the 5 postoperative sessions, the average percentage of correct responses in one monkey, with a relatively precise 7m lesion, decreased from 94.7% to 92.2% (no significance, P > 0.05), while the other monkey, with widely spread necrosis of lateral parietal cortex, showed an. obvious decline in performance, but still over the chance level. After 240 trials this monkey reattained the normal criterion. The results of this research suggest that the lesions of area 7 of the parietal cortex did not significantly affect the short-term visual spatial memory, which has been shown to be sensitive to lesions of the prefrontal cortex; they also support the notion of dissociation of spatial functions in the prefrontal and parietal cortices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a portable recording system and methods for obtaining chronic recordings of single units and tracking rhesus monkey behavior in an open field. The integrated system consists of four major components: (1) microelectrode assembly; (2) h

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whether mice perceive the depth of space dependent on the visual size of object targets was explored when visual cues such as perspective and partial occlusion in space were excluded. A mouse was placed on a platform the height of which is adjustable. The platform located inside a box in which all other walls were dark exception its bottom through that light was projected as a sole visual cue. The visual object cue was composed of 4x4 grids to allow a mouse estimating the distance of the platform relative to the grids. Three sizes of grids reduced in a proportion of 2/3 and seven distances with an equal interval between the platform and the grids at the bottom were applied in the experiments. The duration of a mouse staying on the platform at each height was recorded when the different sizes of the grids were presented randomly to test whether the Judgment of the mouse for the depth of the platform from the bottom was affected by the size information of the visual target. The results from all conditions of three object sizes show that time of mice staying on the platform became longer with the increase in height. In distance of 20 similar to 30 cm, the mice did not use the size information of a target to judge the depth, while mainly used the information of binocular disparity. In distance less than 20 cm or more than 30 cm, however, especially in much higher distance 50 cm, 60 cm and 70 cm, the mice were able to use the size information to do so in order to compensate the lack of binocular disparity information from both eyes. Because the mice have only 1/3 of the visual field that is binocular. This behavioral paradigm established in the current study is a useful model and can be applied to the experiments using transgenic mouse as an animal model to investigate the relationships between behaviors and gene functions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The detection performance regarding stationary acoustic monitoring of Yangtze finless porpoises Neophocaena phocaenoides asiaeorientalis was compared to visual observations. Three stereo acoustic data loggers (A-tag) were placed at different locations near the confluence of Poyang Lake and the Yangtze River, China. The presence and number of porpoises were determined acoustically and visually during each 1-min time bin. On average, porpoises were acoustically detected 81.7 +/- 9.7% of the entire effective observation time, while the presence of animals was confirmed visually 12.7 +/- 11.0% of the entire time. Acoustic monitoring indicated areas of high and low porpoise densities that were consistent with visual observations. The direction of porpoise movement was monitored using stereo beams, which agreed with visual observations at all monitoring locations. Acoustic and visual methods could determine group sizes up to five and ten individuals, respectively. While the acoustic monitoring method had the advantage of high detection probability, it tended to underestimate group size due to the limited resolution of sound source bearing angles. The stationary acoustic monitoring method proved to be a practical and useful alternative to visual observations, especially in areas of low porpoise density for long-term monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, sonar signals and other sounds produced by cetaceans have been used for acoustic detection of individuals and groups in the wild. However, the detection probability ascertained by concomitant visual survey has not been demonstrated extensively. The finless porpoises (Neophocaena phocaenoides) have narrow band and high-frequency sonar signals, which are distinctive from background noises. Underwater sound monitoring with hydrophones (B&K8103) placed along the sides of a research vessel, concurrent with visual observations was conducted in the Yangtze River from Wuhan to Poyang Lake in 1998 in China. The peak to peak detection threshold was set at 133 dB re 1 mu Pa. With this threshold level, porpoises could be detected reliably within 300 m of the hydrophone. In a total of 774-km cruise, 588 finless porpoises were sighted by visual observation and 44 864 ultrasonic pulses were recorded by the acoustical observation system. The acoustic monitoring system could detect the presence of the finless porpoises 82% of the time. A false alarm in the system occurred with a frequency of 0.9%. The high-frequency acoustical observation is suggested as an effective method for field surveys of small cetaceans, which produce high-frequency sonar signals. (C) 2001 Acoustical Society of America.