22 resultados para strain gauge sensor

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

80.00% 80.00%

Publicador:

Resumo:

对氩弧点焊薄片应变传感器传递性能和疲劳性能进行了试验研究,试验结果表明氩弧点焊薄片应变传感器具有稳定传递性能和可靠的疲劳性能,可以应用于实际工程应变测量.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As we all know, rock-like materials will absolutely show very different mechanical properties under the compressive stress and tensile stress respectively. Similarly, under the dynamic compressive stress or dynamic tensile stress, the characteristics of the dynamics showed by the rock-like materials also have great differences from the mechanical behavior under static force. Studying their similarities and differences in rock mechanics theory and practical engineering will be of great significance. Generally, there are compression modulus of elasticity and tensile modulus of elasticity corresponding to compressive stress state and the tensile stress state in the rock. Both the two kinds of elastic modulus play an extremely important role in calculation of engineering mechanics. Their reliability directly affects the accuracy and reliability of the calculation results of internal stress field and displacement field of engineering rock mass. At present, it is easy to obtain the compression modulus of elasticity in laboratory; but it is very difficult to determine the tensile modulus of elasticity with direct tensile test due to that direct tensile test is difficult to perform in laboratory in general. In order to solve this problem, this thesis invents and develops several indirect test methods to determine the static or dynamic tensile modulus of elasticity of rock-type materials with high reliability and good interoperability. For the static tensile modulus of elasticity, the analytical stress field solution has been given out for the Brazilian disc under the radial and linear concentration load with Airy stress function method. At the same time, the stress field has been modeled for the Brazilian disc test by using the finite element software of ANSYS and ADINA. The analytical stress field solution is verified to be right by comparatively researching the analytical stress field solution and the numerical stress field solution. Based on the analytical stress field solution, this thesis proposes that a strain gauge is pasted at the Brazilian disc center along the direction perpendicular to the applied force to indirectly determine the static tensile modulus of elasticity, and related measurement theory also has been developed. The method proposed here has good feasibility and high accuracy verified by the experimental results. For the dynamic tensile modulus of elasticity, two measuring methods and theories are invented here. The first one is that the Split Hopkinson Pressure Bar is used to attract the Brazilian disc to generate the dynamic load, make the dynamic tensile stress is formed at the Brazilian disc center; and also a strain gauge is pasted at the Brazilian disc center to record the deformation. The second is that, in the Hopkinson effect phenomenon, the reflection tensile stress wave is formed when the shock wave propagates to the free end of cylindrical rock bar and reflect, which can make the rock bar is under dynamic tensile stress state; and some strain gauges are pasted at the appropriate place on the rock bar to record the strain coursed by the tensile or compressive stress wave. At last, the dynamic tensile modulus of elasticity can be determined by the recorded strain and the dynamic tensile stress which can be determined by related theories developed in this thesis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new packaged fiber Bragg grating using bimetal cantilever beam as the strain agent is presented. The grating is two-point attached on one specific surface of the bimetal beam which consists of two metallic material with different thermal-expansion coefficient. Thereby the grating can be compressed or stretched along with the cantilever beam while temperature varies and temperature compensation can be realized. At the same time, grating chirping can be avoided for the particular attaching method. Experiment results demonstrated that the device is able to automatically compensate temperature induced wavelength shift. The temperature dependence of Bragg wavelength reduced to -0.4 pm/degrees C over the temperature range from -20 to 60 degrees C. This fiber grating package technique is cost effective and can be used in strain sensing. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fiber Bragg grating (FBG) sensor for monitoring the electromagnetic strain in a low temperature superconducting (LTS) magnet was studied. Before used to LTS magnet strain sensing, the strain response of the sensor with 1.54-mu m wavelength at liquid helium was experimentally studied. It was found that the wavelength shift showed good linearity with longitudinal applied loads and the strain sensitivity is constant at 4.2 K. And then, the hoop strain measurement of a LTS magnet was carried out on the basis of measured results. Furthermore, the finite element method (FEM) was used to simulate the magnet strain. The difference between the experimental and numerical analysis results is very small.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fiber Bragg grating (FBG) sensor for monitoring the electromagnetic strain in a low temperature superconducting (LTS) magnet was studied. Before used to LTS magnet strain sensing, the strain response of the sensor with 1.54-mu m wavelength at liquid helium was experimentally studied. It was found that the wavelength shift showed good linearity with longitudinal applied loads and the strain sensitivity is constant at 4.2 K. And then, the hoop strain measurement of a LTS magnet was carried out on the basis of measured results. Furthermore, the finite element method (FEM) was used to simulate the magnet strain. The difference between the experimental and numerical analysis results is very small.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel fiber Bragg grating (FBG) sensor for the measurement of high temperature is proposed and experimentally demonstrated. The interrogation system of the sensor system is simple, low cost but effective. The sensor head is comprised of one FBG and two metal rods. The lengths of the rods are different from each other. The coefficients of thermal expansion of the rods are also different from each other. The FBG will be strained by the sensor head when the temperature to be measured changes. The temperature is measured basis of the wavelength shifts of the FBG induced by strain. A dynamic range of 0-800 degrees C and a resolution of 1 degrees C have been obtained by the sensor system. The experiment results agree with theoretical analyses. (c) 2007 Elsevier GmbH. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel fiber Bragg grating (FBG) sensor system based on an interrogating technique by two parallel matched gratings was designed and theoretically discussed. With an interrogation grating playing the role of temperature compensation grating simultaneously, the wavelength drifts induced by temperature and strain were discriminated. Additionally, the expressions of temperature and strain were deduced for our solution, and dual-value problem and cross sensitivity were solved synchronously through data processing. The influence of the FBG's parameters on the dynamic range and precision was discussed. Besides, the change of environment temperature cannot influence the dynamic range of the sensor system through temperature tuning. The system proposed in this paper will be of great significance to accelerate the real engineering applications of FBG sensing techniques. (c) 2007 Elsevier GmbH. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The key issues of engineering application of the dual gratings parallel matched interrogation method are expanding the measurable range, improving the usability, and lowering the cost by adopting a compact and simple setup based on existing conditions and improving the precision of the data-processing scheme. A credible and effective data-processing scheme based on a novel divisional look-up table is proposed based on the advantages of other schemes. Any undetermined data is belonged to a certain section, which can be confirmed at first, then it can be looked up in the table to correspond to microstrain by the scheme. It not only solves inherent problems of the traditional one (double value and small measurable range) but also enhances the precision, which improves the performance of the system. From the experimental results, the measurable range of the system is 525 mu epsilon, and the precision is +/- 1 mu epsilon based on normal matched gratings. The system works in real time, which is competent for most engineering measurement requirements. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel fiber Bragg grating (FBG) pressure sensor based on the double shell cylinder with temperature compensation is presented. in the sensing scheme, a sensing FBG is affixed in the tangential direction on the outer surface of the inner cylinder, and another FBG is affixed in the axial direction to compensate the temperature fluctuation. Based on the theory of elasticity, the theoretical analysis of the strain distribution of the sensing shell is presented. Experiments are carried out to test the performance of the sensor. A pressure sensitivity of 0.0937 nm/MPa has been achieved. The experimental results also demonstrate that the two FBGs have the same temperature sensitivity, which can be utilized to compensate the temperature induced wavelength shift during the pressure measurement. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study develops a fiber Bragg grating (FBG) pressure sensor partly shielded with a metal tube. The thermal-strain cross effect is avoided and its pressure sensitivity is increased to -2.44 x 10(-3) MPa, about 1200 times as that of a bare fiber grating. Due to its good sensing linearity, this sensor can be applied in the measurement of hydraulic pressure and vibration. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An enhanced technique for interrogating fiber Bragg grating wavelength shift using cascade wavelength division multiplexer (WDM) couplers was proposed and demonstrated. Three WDM couplers which show a linear filter function over the expected wavelength range are employed and cascaded to track Bragg wavelength shifts. Compared with single WDM demodulator. sharper spectral slope is obtained and considerable linear filter range is kept. The static and dynamic strain sensor demodulation experiments demonstrated that the simple passive technique improves the sensitivity approximately two times and keeps 5nm linear demodulation range based on our devices. The cascade WDM coupler demodulation system has high scan rate which can be used to monitor fast vibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

alpha-titanium and its alloys with a dual-phase structure (alpha+beta) were deformed dynamically under strain rate of about 10(4) s(-1). The formation and microstructural evolution of the localized shear bands were characterized by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The results reveal that both the strain and strain rate should be considered simultaneously as the mechanical conditions for shear band formation, and twinning is an important mode of deformation. Both experimental and calculation show that the materials within the bands underwent a superhigh strain rate (9 x 10(5) s(-1)) deformation, which is two magnitudes of that of average strain rate required for shear band formation; the dislocations in the bands can be constricted and developed into cell structures; the phase transformation from alpha to alpha(2) within the bands was observed, and the transformation products (alpha(2)) had a certain crystallographic orientation relationship with their parent; the equiaxed grains with an average size of 10 mu m in diameter observed within the bands are proposed to be the results of recrystallization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the 'average stress in the matrix' concept of Mori and Tanaka (:Mori, T., Tanaka, K., 1973. Average stress in matrix and average elastic energy of materials with misfitting inclusion. Acta Metall. 21, 571-580) a micromechanical model is presented for the prediction of the elastic fields in coated inclusion composites with imperfect interfaces. The solutions of the effective elastic moduli for this kind of composite are also obtained. In two kinds of composites with coated particulates and fibers, respectively, the interface imperfections are takes to the assumption that the interface displacement discontinues are linearly related to interface tractions like a spring layer of vanishing thickness. The resulting effective shear modulus for each material and the stress fields in the composite are presented under a transverse shear loading situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

对薄板成形应变场传统的测量方法进行了研究,指出了其不足和误差的来源,提出了数字图像分析法测量薄板成形中的应变场,对测量原理、新的测量方法对传统方法的改进,以及如何降低误差进行了介绍,指出数字图像分析法的前景,提出了改进意见。