10 resultados para reusable

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High temperature chemical non-equilibrium phenomena have a great effect on the flow field around a reentry vehicle. A set of three dimensional Navier-Stokes equations have been solved by implicit finite volume NND scheme. Both ideal gas viscous flow and chemical non-equilibrium flow are calculated for a spherical-cone at a small angle of attack. The results of the two flows have been compared and the effect of chemical non-equilibrium has been analyzed. The effect of wall material's properties, such as catalysis and radiation were studied. The results are in good agreement with the referenced paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a sensitive electrochemical aptasensor for adenosine based on electrochemical impedance spectroscopy measurement, which gives not only a label-free but also a reusable platform to make the detection of small molecules simple and convenient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An indirect inhibitive surface plasmon resonance (SPR) immunoassay was developed for the microcystins (MCs) detection. The bioconjugate of MC-LR and bovine serum albumin (BSA) was immobilized on a CM5 sensor chip. A serial premixture of MC-LR standards (or samples) and monoclonal antibody (mAb) were injected over the functional sensor surface, and the subsequent specific immunoreaction was monitored on the BIAcore 3000 biosensor and generated a signal with an increasing intensity in response to the decreasing MCs concentration. The developed SPR immunoassay has a wide quantitative range in 1-100 mu g L-1. Although not as sensitive as conventional enzyme-linked immunosorbent assay (ELISA), the SPR biosensor offered unique advantages: (I) the sensor chip could be reusable without any significant loss in its binding activity after 50 assay-regeneration cycles, (2) one single assay could be accomplished in 50 min (including 30-min preincubation and 20-min BIAcore analysis), and (3) this method did not require multiple steps. The SPR biosensor was also used to detect MCs in environmental samples, and the results compared well with those obtained by ELISA. We conclude that the SPR biosensor offers outstanding advantages for the MCs detection and may be further developed as a field-portable sensor for real-time monitoring of MCs on site in the near future. (C) 2009 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With long-term marine surveys and research, and especially with the development of new marine environment monitoring technologies, prodigious amounts of complex marine environmental data are generated, and continuously increase rapidly. Features of these data include massive volume, widespread distribution, multiple-sources, heterogeneous, multi-dimensional and dynamic in structure and time. The present study recommends an integrative visualization solution for these data, to enhance the visual display of data and data archives, and to develop a joint use of these data distributed among different organizations or communities. This study also analyses the web services technologies and defines the concept of the marine information gird, then focuses on the spatiotemporal visualization method and proposes a process-oriented spatiotemporal visualization method. We discuss how marine environmental data can be organized based on the spatiotemporal visualization method, and how organized data are represented for use with web services and stored in a reusable fashion. In addition, we provide an original visualization architecture that is integrative and based on the explored technologies. In the end, we propose a prototype system of marine environmental data of the South China Sea for visualizations of Argo floats, sea surface temperature fields, sea current fields, salinity, in-situ investigation data, and ocean stations. An integration visualization architecture is illustrated on the prototype system, which highlights the process-oriented temporal visualization method and demonstrates the benefit of the architecture and the methods described in this study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aptamers, which are in vitro selected functional oligonucleotides, have been employed to design novel biosensors (i.e., aptasensors) due to their inherent selectivity, affinity, and their multifarious advantages over traditional recognition elements. In this work, we reported a multifunctional reusable label-free electrochemical biosensor based on an integrated aptamer for parallel detection of adenosine triphosphate (ATP) and alpha-thrombin, by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). A An electrode as the sensing surface was modified with a part DNA duplex which contained a 5'-thiolated partly complementary strand (PCS) and a mixed aptamer (MBA).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new method for electrochemically in situ conductivity measurements based on a reusable glassy carbon disc carbon fibre array double electrode is described. Using this technique and cyclic voltammetry, we have investigated the effects of the doping anion and solvent on the electrochemical properties of polypyrrole film. The electroactivity and potential dependent conductivity of polypyrrole film are strongly affected by solvent and the doping anion's solubility in the solvent, and also by the history of electrochemical treatments in different electrolyte solutions. It is very interesting that NO3-doped polypyrrole can completely keep its conducting state (doped state) at a reasonably negative potential (eg -0.8 V vs. sce) in acetonitrile solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出了IDEF与UML两者结合的系统建模方法,能够有效地避免IDEF对信息过程流建模和UML语义描述精确性及使用灵活性的不足.该方法采用IDEF0进行系统功能建模,用IDEF1x和UML模型进行信息建模和面向对象的软件系统设计.用该方法设计的沈阳某冶金设备有限公司的基于组件的生产过程管理系统模型具有良好的维护性、可扩展性和重用性,证明了该方法的可行性.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

介绍了一个基于组件的可重构车间管理系统,分别从建模方法、体系结构和组件设计等角度描述了系统的设计思想,并阐述了系统涉及的组件分类、组件粒度划分及XML的应用等关键设计技术。开发的可重构车间管理系统已经用于沈阳第一机床厂两个不同类型生产车间的管理,应用效果良好。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We conducted the liquid phase oxidation of toluene with molecular oxygen over heterogeneous catalysts of copper-based binary metal oxides. Among the copper-based binary metal oxides, iron-copper binary oxide (Fe/Cu = 0.3 atomic ratio) was found to be the best catalyst. In the presence of pyridine, overoxidation of benzaldehyde to benzoic acid was partially prevented. As a result, highly selective formation of benzaldehyde (86% selectivity) was observed after 2 h of reaction (7% conversion of toluene) at 463 K and 1.0 MPa of oxygen atmosphere in the presence of pyridine. These catalytic performances were similar or better than those in the gas phase oxidation of toluene at reaction temperatures higher than 473 K and under 0.5-2.5 MPa. It was suggested from competitive adsorption measurements that pyridine could reduce the adsorption of benzaldehyde. At a long reaction time of 4 It, the conversion increased to 25% and benzoic acid became the predominant reaction product (72% selectivity) in the absence of pyridine. The yield of benzoic acid was higher than that in the Snia-Viscosa process, which requires corrosive halogen ions and acidic solvents in the homogeneous reaction media. The catalyst was easily recycled by simple filtration and reusable after washing and drying.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An immunosorbent was fabricated by encapsulation Of monoclonal anti-isoproturon antibodies in sol-gel matrix. The immunosorbent-based loading, rinsing and eluting processes were optimized. Based on these optimizations, the sol-gel immunosorbent (SG-IS) selectively extracted isoproturon from an artificial mixture of 68 pesticides. In addition to this high selectivity, the SG-IS proved to be reusable. The SG-IS was combined with liquid chromatography-tandem mass spectrometry (LC-MS-MS) to determine isoproturon in surface water, and the linear range was up to 2.2 mu g/l with correlation coefficient higher than 0.99 and relative standard deviation (RSD) lower than 5% (n = 8). The limit of quantitation (LOQ) for 25-ml surface water sample was 5 ng/l. (c) 2006 Elsevier B.V. All rights reserved.