22 resultados para real von Neumann measurement

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

As there exist some problems with the previous laser diode (LD) real-time microvibration measurement interferometers, such as low accuracy, correction before every use, etc., in this paper, we propose a new technique to realize the real-time microvibration measurement by using the LD sinusoidal phase-modulating interferometer, analyze the measurement theory and error, and simulate the measurement accuracy. This interferometer utilizes a circuit to process the interference signal in order to obtain the vibration frequency and amplitude of the detective signal, and a computer is not necessary in it. The influence of the varying light intensity and light path difference on the measurement result can be eliminated. This technique is real-time, convenient, fast, and can enhance the measurement accuracy too. Experiments show that the repeatable measurement accuracy is less than 3.37 nm, and this interferometer can be applied to real-time microvibration measurement of the MEMS. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

现有的半导体激光干涉仪存在测量精度与测量范围的矛盾。本文提出一种新的实时位移测量半导体激光干涉仪,并分析了干涉仪的测量原理。首先提出一种新的解相算法,它通过两路实时相位探测电路从干涉信号中得到待测量相位,消除了光强波动、初始光程差、电路放大倍数、调制深度、Bessel函数等参数对测量精度的影响,提高了测量精度。其次,提出一种扩大测量范围的技术,并用解包裹电路得到真实相位和待测量的位移, 将测量范围从半个波长提高到几个波长。在实验中,测得喇叭的峰峰值为2361.7nm,重复测量精度为2.56nm,测量时间为

Relevância:

100.00% 100.00%

Publicador:

Resumo:

差分吸收法是进行瓦斯远距离监测的重要方法,根据瓦斯在近红外波段的吸收特性,报道了一种新型的远距离光纤瓦斯传感系统。采用1.3μm超辐射发光二极管为光源,利用光纤布拉格光栅(FBG)优良的窄带滤波特性实现了对瓦斯的差分吸收测量。和传统的干涉滤光片相比,光纤光栅滤波器插入损耗低、制备简单。系统具有全光纤化、结构简单、工作距离远、稳定性好的特点。工作距离10km,测量灵敏度为0.1%,是瓦斯爆炸极限的2%。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

采用一种特殊的二次光栅用于激光波前测量, 它对非零级衍射光束具有不同的聚焦效应, 其光栅线为圆弧型而非直线。导出了在会聚光束情况下的两平面成像在单一像平面上的距离关系, 实验上实现了二次光栅用于会聚光束的波前测量, 测量得到会聚光束具有较大的散焦(-2.93λ)和球差(1.34λ), 与该透镜引起波前的离焦像差理论理想值(-2.695λ)基本符合。该技术可以实现波前的高空间分辨力和高精度实时测量, 大大减少光学元件数量, 降低装置成本。由于大功率激光束的不稳定性, 其波前变化非常快, 所以该方法的实时性非

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Based on the semiconductor laser whose spectral line with width is compressed to be less than 1.2Mhz, a system was designed to measure and improve the amplitude and frequency of the real-time microvibration with sinusoidal modulation. real-time microvibration measurement was executed without alignment problem in the interferometry; and low-frequency disturbance of environment could be eliminated. Suggestions were also given to consummate the system. The system also has resistance against the low frequency disturbance of the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

现代多脉冲及2D NMR技术是过去十年中发展起来的崭新的NMR实验方法。计算机模拟做为NMR实验的强有力分析手段已日益受到重视。国内这方面工作开展得尚很少;国外发表的工作主要采用的是数字模拟,存在分析结果不够直观、物理意义不够清晰等缺陷。本论文工作采用乘积算符方法研制出对分析多脉冲及2D NMR实验普适的模拟程序PROPER;在乘积算符基础上,针对磁等性自旋体系,提出了实用的对称化乘积算符及多量子积算符方法。一、多脉冲及2D NMR实验的计算机模拟 1. 采用乘积算符方法在本所PDP-11/23微机上研制了多脉冲及2D NMR实验的模拟程序PROPER。该程序对不超过4核(I = 1/2)的同核及异核弱耦合自旋体系非选择性脉冲序列的分析是普遍适用的。受计算机内存的限制,PROPER程序所能处理的脉冲序列脉冲间隔数目一般不超过10。2. 应用PROPER模拟程序对INEP和DEPT脉冲序列进行了分析比较;特别对BIRD脉冲序列的各种相位变型进行了模拟分析,给出了分析结果,分析过程中考虑了影响BIRD作用效果的同核耦合因素。应用结果表明,PROPER程序计算正确、迅速、给出的模拟结果较通常的数字模拟方法简单、直观、物理意义清楚,便于分析。由于采用算符模拟,结果的输出打印比较费时。目前,PROPER程序正在改进和完善之中。二、多脉冲及2D NMR实验的密度算符描述 1. 针对磁等性自旋(I = 1/2)体系,首次提出了对称化乘积算符描述方法。在通常的乘积算符基础上,引入了对称化乘积算符,并对其数理基础进行了详细论证。推导了算符循环对易关系决定的Liourill-Von Neumann方程的解,给出了算符间普遍存在的循环对易关系及其相应的演化公式。据此,以InS(I = 1/2, S = 1/2; n = 2,3)自旋体系为例,对DEPT脉冲序列进行了分析;结果表明,该方法较通常的乘积算符方法对磁等性自旋体系的分析要简单、实用,且物理意义更加明确。由于该方法涉及较多的算符对易关系,因此不易计算机编程。2. 在对称化乘积算符基础上引入了多量子积算符的概念。以In(I = 1/2; n = 2,3)体系为例,给出了两者的互换关系。推导出了具有标量耦合作用的两组合粒子体系普适的多量子积算符环对易关系及相应的演化解析式。多量子积算符方法可望将1/2-自旋磁等性组合粒子表象与自旋大于1/2的单粒子表象统一起来,并为计算机模拟提供新的数学方法。该方法尚有待于进一步研究。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

本文通过理论分析,将三维对称双楔面上定常激波相互作用简化到二维截面进行分析,利用二维非定常激波楔面反射理论求解该三维激波相互作用结构。同时,通过采用二阶精度的NND格式求解三维Euler方程,对该理论分析结果做出数值模拟验证。理论分析和数值模拟结果显示,对于三维双楔面超声速定常流动在取定的二维截面上激波结构兼有二维非定常及定常激波反射的性质,即形成了类似于二维非定常激波楔面反射的规则反射、单马赫反射、过渡马赫反射及双马赫反射等结构,同时其规则—马赫反射转变却遵循适用于二维定常激波反射的von Neumann准则。理论分析得出的各种反射结构的存在范围与数值模拟结果吻合良好。同时,探讨了两楔面间夹角以及楔面前缘后掠角对该激波结构的影响。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

VonNeumann熵研究了附加克尔介质的压缩真空场与二能级原子依赖强度耦合相互作用量子体系的量子纠缠特性 .讨论了初始压缩真空场的压缩度以及克尔非线性作用的强度对该量子体系纠缠特性的影响 .结果表明 ,克尔介质的非线性作用的强弱可以改变体系量子纠缠的周期性 ;在初始压缩度较大 (r =5 )时 ,克尔介质的非线性作用可导致原子与场持续地处于最大纠缠态 ,无消纠缠态或持续地处于消纠缠态 .

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the real-time deformation fields are observed in two different kinds of hole-excavated dog-bone samples loaded by an SHTB, including single hole sample and dual holes sample with the aperture size of 0.8mm. The testing system consists of a high-speed camera, a He-Ne laser, a frame grabber and a synchronization device with the controlling accuracy of I microsecond. Both the single hole expanding process and the interaction of the two holes are recorded with the time interval of 10 mu s. The observed images on the sample surface are analyzed by newly developed software based on digital correlation theory and a modified image processing method. The 2-D displacement fields in plane are obtained with a resolution of 50 mu m and an accuracy of 0.5 mu m. Experimental results obtained in this paper are proofed, by compared with FEM numerical simulations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, a real-time and in situ optical measuring system is reported to observe high-velocity deformations of samples subjected to impact loading. The system consists of a high-speed camera, a He-Ne laser, a frame grabber, a synchronization device and analysis software based on digital correlation theory. The optical system has been adapted to investigate the dynamic deformation field and its evolution in notched samples loaded by an split Hopkinson tension bar, with a resolution of 50 pin and an accuracy of 0.5 mum. Results obtained in experiments are discussed and compared with numerical simulations. It is shown that the measuring system is effective and valid.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, the real-time deformation fields are observed in two different kinds of hole-excavated dog-bone samples loaded by an SHTB, including single hole sample and dual holes sample with the aperture size of 0.8mm. The testing system consists of a high-speed camera, a He-Ne laser, a frame grabber and a synchronization device with the controlling accuracy of I microsecond. Both the single hole expanding process and the interaction of the two holes are recorded with the time interval of 10 mu s. The observed images on the sample surface are analyzed by newly developed software based on digital correlation theory and a modified image processing method. The 2-D displacement fields in plane are obtained with a resolution of 50 mu m and an accuracy of 0.5 mu m. Experimental results obtained in this paper are proofed, by compared with FEM numerical simulations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An external cavity semiconductor laser interferometer used to measure far distance micro-vibration in real time is proposed. In the interferometer, a single longitudinal mode and excellent coherent characteristic grating external cavity semiconductor laser is constructed and acted as a light source and a phase compensator. Its coherent length exceeds 200 meters. The angle between normal and incidence beam of the far object is allowed to change in definite range during the measurement with this interferometer, and this makes the far distance interference measurement easier and more convenient. Also, it is not required to keep the amplitudes of the first and second harmonic components equal, and then the dynamic range is increased. A feedback control system is used to compensate the phase disturbance between the two interference beams introduced by environmental vibration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thermal properties of a micro-electromechanical system sensor were analysed by a novel digital moire method. A double-layer micro-cantilever sensor (60 mu m long, 10 mu m width and 2 mu dm thick) was prepared by focused ion beam milling. A grating with frequency of 5000 lines mm- I was etched on the cantilever. The sensor was placed into a scanning electron microscope system with a high temperature device. The observation and recording of the thermal deformation of the grating were realised in real-time as the temperature rose from room temperature to 300 degrees C at intervals of 50 degrees C. Digital moire was generated by interference of the deformed grating and a digital virtual grating. The thermal properties including strain distribution of the sensor and the linear expansion coefficient of polysilicon were accurately measured by the phase-shifted moire patterns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two principal problems of equivalency and locality in nano-scale measurement are considered in this paper. The conventional measurements of force and displacement are always closely related to the equivalency problem between the measuremental results by experimental system and the real physical status of the sample, and the locality of the mechanical quantities to be measured. There are some noticeable contradictions in nano-scale measurements induced by the two problems. In this paper, by utilizing a coupled molecular-continuum method, we illustrate the important effects of the two principal problems in atomic force microscopy (AFM) measurements on nano-scale. Our calculations and analysis of these typical mechanical measurement problems suggest that in nano-meter scale measurements, the two principal problems must be carefully dealt with. The coupled molecular-continuum method used in this paper is very effective in solving these problems on nano-scale.