188 resultados para quadrupole ion-trap
em Chinese Academy of Sciences Institutional Repositories Grid Portal
Resumo:
Direct-injection electrospray ionization mass spectrometry in combination with information-dependent data acquisition (IDA), using a triple-quadrupole/linear ion trap combination, allows high-throughput qualitative analysis of complex phospholipid species from child whole blood. In the IDA experiments, scans to detect specific head groups (precursor ion or neutral loss scans) were used as survey scans to detect phospholipid classes. An enhanced resolution scan was then used to confirm the mass assignments, and the enhanced product ion scan was implemented as a dependent scan to determine the composition of each phospholipid class. These survey and dependent scans were performed sequentially and repeated for the entire duration of analysis, thus providing the maximum information from a single injection. In this way, 50 different phospholipids belonging to the phosphatidylethanolamine, phosphatidylserine, phosphatidylinositol, phosphatidylcholine and sphingomyelin classes were identified in child whole blood. Copyright (C) 2005 John Wiley & Sons, Ltd.
Resumo:
A method for calibration of an audio-frequency (AF) ion trap mass spectrometer is described. The method is proposed to surmount the obstacle that there is a lack of a proper calibrant for mass spectrometers in the mass-to-charge ratio (m/z) range of 10(6) to 10(10). To calibrate such mass spectra, we determine the point of ejection, q(eject), on the stability diagram of the ion trap operated in a mass-selective axial instability mode. This is accomplished by measuring the radial secular frequencies (and therefore, the m/z value) of a single trapped particle using a light scattering method, followed by monitoring the action of particle ejection in real time to obtain the q(eject). A delayed ejection with q(eject) = 0.949 +/- 0.004 is found at a trap driving frequency of Ohm/2pi = 200-600Hz. Theoretical analysis for the origin of the delayed ejection indicates that the delay is predominantly resulted from the existence of multipole components in the fields due to trap imperfections. Inclusion of -3% of the octopole with respect to the basic quadrupole field can satisfactorily account for our observations. An m/z accuracy approaching 0.1% is attainable after proper calibration of the AF ion trap mass spectrometer. (Int J Mass Spectrom 214 (2002) 63-73) (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Since protein phosphorylation is a dominant mechanism of information transfer in cells, there is a great need for methods capable of accurately elucidating sites of phosphorylation. In recent years mass spectrometry has become an increasingly viable alternative to more traditional methods of phosphorylation analysis. The present study used immobilized metal affinity chromatography (IMAC coupled with a linear ion trap mass spectrometer to analyze phosphorylated proteins in mouse liver. A total of 26 peptide sequences defining 26 sites of phosphorylation were determined. Although this number of identified phosphoproteins is not large, the approach is still of interest because a series of conservative criteria were adopted in data analysis. We note that, although the binding of non-phosphorylated peptides to the IMAC column was apparent, the improvements in high-speed scanning and quality of MS/MS spectra provided by the linear ion trap contributed to the phosphoprotein identification. Further analysis demonstrated that MS/MS/MS analysis was necessary to exclude the false-positive matches resulting from the MS/MS experiments, especially for multiphosphorylated peptides. The use of the linear ion trap considerably enabled exploitation of nanoflow-HPLC/MS/MS, and in addition MS/MS/MS has great potential in phosphoproteome research of relatively complex samples. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
The electrospray ionization ion trap multiple-stage tandem mass spectrometry (ESI-MSn) and electrospray ionization Fourier transform ion cyclotron resonance multiple-stage tandem mass spectrometry (ESI-FT-ICR-MSn) have been applied successfully to the direct investigation of a number of dibenzocyclooctadiene lignan constituents from the methanol extracts of the Fructus Schisandrae in the positive ion mode. The detailed structural characterization of the same skeleton and different peripheral substituents had been studied and the precise elemental compositions of ions at high mass resolution had been obtained. So the fragmentation mechanisms could be clarified.
Resumo:
Incubated solutions containing glutathione (GSH) and alpha- or beta-cyclodextrins (CDs) were analyzed using electrospray mass spectrometry and tandem mass spectrometry, The results suggest that both CDs can catalyze oxidation of GSH to the oxidized glutathione (GSSG). The collision-induced dissociation (CID) of the 1:1 and 1:2 (CD/GSH) and 1:1 (CD/GSSG) complexes reveals the strong interactions of the CDs with the peptides tested. The 1:2 (CD/GSH) complex is considered to be the oxidation reaction intermediate, which indicates that the three-dimensional structure of the complexed two GSHs in CD complexes Is different from that of the proton-bound GSH dimer, The oxidation product, GSSG, Is also observed in the CID spectrum of the singly charged 1:1 (CD/GSH) complex, suggesting that a complex ion-complex ion reaction occurs by forming a doubly charged complex dimer, as a result of the ability of ion trap to accumulate and activate ions. The observations indicate that ion trap mass spectrometry can be used to explore cyclodextrin-catalyzed reactions and to carry out complex gaseous chemistry research. Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
Two methods for tetrodotoxin analysis using liquid chromatography coupled with electrospray iontrap mass spectrometry (LC-ESI-MS) have been established with C,, reversed phase column and hydrophilic interaction liquid chromatography (HILIC) column, respectively. Sensitivity and reproducibility of the methods were compared. The method using C-18 column in selected ion monitoring (SIM) mode had a detection limit (S/N = 3) of 120 pg, and a good linearity of the calibration curve was obtained for tetrodotoxin (r = 0. 9992). High reproducibility of the method was observed, with a relative standard deviation (RSD) below 10%. The method using HILIC column in SIM mode and selected reaction monitoring (SRM) mode had detection limits (S/N = 3) of 15 and 3.75 pg, respectively. Good linearity of the calibration curves was obtained for tetrodotoxin (r = 0. 9996 and 0. 9998 in SIM and SRM mode, respectively). T he reproducibility was high in SIM mode but relatively poor in SRM mode. Based on the results, the method using HILIC column in SIM mode was suggested for the analysis of tetrodotoxin with LC-MS system.
Resumo:
A resurgence of interest in the human plasma proteome has occurred in recent years because it holds great promise of revolution in disease diagnosis and therapeutic monitoring. As one of the most powerful separation techniques, multidimensional liquid chromatography has attracted extensive attention, but most published works have focused on the fractionation of tryptic peptides. In this study, proteins from human plasma were prefractionated by online sequential strong cation exchange chromatography and reversed-phase chromatography. The resulting 30 samples were individually digested by trypsin, and analyzed by capillary reversed-phase liquid chromatography coupled with linear ion trap mass spectrometry. After meeting stringent criteria, a total of 1292 distinct proteins were successfully identified in our work, among which, some proteins known to be present in serum in < 10 ng/mL were detected. Compared with other works in published literatures, this analysis offered a more full-scale list of the plasma proteome. Considering our strategy allows high throughput of protein identification in serum, the prefractionation of proteins before MS analysis is a simple and effective method to facilitate human plasma proteome research.
Resumo:
We propose a surface planar ion chip which forms a linear radio frequency Paul ion trap. The electrodes reside in the two planes of a chip, and the trap axis is located above the chip surface. Its electric field and potential distribution are similar to the standard linear radio frequency Paul ion trap. This ion trap geometry may be greatly meaningful for quantum information processing.
Resumo:
Paeoniflorin standard was first investigated by electrospray ionization Fourier transform ion cyclotron resonance tandem mass spectrometry (ESI-FTICR-MS/MS) using a sustained off-resonance irradiation (SORI) collision-induced dissociation (CID) method at high mass resolution. The experimental results demonstrated that the unambiguous elemental composition of product ions can be obtained at high mass resolution. Comparing MS/MS spectra and the experimental methods of hydrogen and deuterium exchange, the logical fragmentation pathways of paeoniflorin have been proposed. Then, the extracts of the traditional Chinese medicine Paeonia lactiflora Pall. were analyzed by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry (HPLC/ESI-MS/MS). By comparison with the ESI-FTICR-MS/MS data of paeoniflorin, the isomers paeoniflorin and albiflorin in Paeonia lactiflora Pall. have been identified using HPLC/MS with CID in an ion trap and in-source CID. Furthermore, using the characteristic fragmentation pathways, the retention times (t(R)) in HPLC and MS/MS spectra, the structures of three other kinds of monoterpene glycoside compounds have been identified on-line without time-consuming isolation.
Resumo:
本论文由四部分组成。第一部分报道了佛手参提取物的化学成分研究,建立了活性成分含量测定的高效液相测定和指纹图谱研究,采用液质联用技术鉴定了主要色谱峰;第二部分报道了丹参及其复方制剂的特征图谱研究;第三部分探讨了两面针生物碱的电喷雾质谱裂解规律,并采用液质联用技术分离鉴定了提取物中的多种生物碱。第四部分概述了液质联用在药物代谢研究中的运用。 第一部分包括第一、第二和第三章。第一章针对佛手参(Gymnadeniaconopsea)块茎的甲醇提取物,采用大孔树脂和反相硅胶柱层析等各种分离方法,共分离鉴定出4 个化合物,通过波谱分析将它们的结构确定为dactylorhin B (1)、loroglossin (2)、dactylorhin A (3)和militarine (4)。这4 个化合物均是首次从佛手参中分离得到的琥珀酸葡萄糖苷类成分。第二章采用高效液相色谱法对西藏、四川、河北、青海和尼泊尔等不同地区产的十个佛手参样品进行腺嘌呤核苷和对羟基苯甲醇的定量分析,结果表明这2 个成份可视为佛手参的特征成分,但也注意到产地不同该2 个特征成分的含量也有所不同。第三章采用标准中药指纹图谱相似度计算软件,以10 个佛手参样品HPLC 图谱的平均值为相似性评价对照模板,对10 个样品进行了相似度评价,并经液质联用分析指认了7 个共有峰,分别为腺嘌呤核苷(1)、对羟基苯甲醇(2)、对羟基苯甲醛(3) 、dactylorhin B(4) 、loroglossin(5)、dactylorhin A(6)和militarine(7)。 第二部分包括第四、第五、第六和第七章。第四章运用电喷雾质谱检测了对照药材和五个不同产地的丹参药材中脂溶性和水溶性成分,系统地探讨了多种成分的电喷雾质谱规律,并以对照药材为标准建立了特征指纹图谱。五个产地的药II材通过与对照药材相对比,采用聚类分析的方法,得到了定性的鉴别与判断。并采用液质联用技术对丹参药材提取液中的化学成份进行分析,推测了九个特征峰,并对六样品的液相色谱图进行了聚类分析。第五章探讨了三七皂苷的电喷雾质谱电离和裂解规律,并采用电喷雾质谱法对三七标准药材,血通片中的皂苷成分进行了分析。第六章运用电喷雾质谱研究复方丹参片提取液的特征图谱,并和单味药材丹参和三七的特征图谱进行了对比研究。并运用HPLC-ESI MSn 分析鉴定了复方丹参片提取液中的化学成分,推测了12 个色谱峰。第七章总结了电喷雾质谱和液质联用技术在丹参药材,三七药材及复方丹参制剂中的运用的优势和局限性。 第三部分(第八章)研究了两面针生物碱中二氢白屈菜红碱(1)、二氢两面针碱(2)、8-酮基二氢白屈菜红碱(3)、8-丙酮基二氢两面针碱(4)、两面针碱(5)、和1,3-二(8-二氢两面针碱)丙酮(6)等六个苯并菲啶型生物碱的电喷雾质谱裂解规律,其中二氢两面针碱和二氢白屈菜红碱,8-丙酮基二氢两面针碱和8-酮基二氢白屈菜红碱是两对二个甲氧基分别在C-9 和C-10,C-10 和C-11 的同分异构体。实验结果表明,在相同的碰撞能下,这类位置异构体的ESI MS2 质谱二级碎片离子的相对峰度存在很大差异,这可以用于区分该类同分异构体,采用液-质联用可以对两面针的总生物碱提取物中的这些同分异构体加于区分。同时在本实验采用的液相色谱条件下,多种生物碱得到较好的分离,通过和对照品的保留时间,紫外吸收光谱及电喷雾质谱图对照,鉴定了11 个主要色谱峰。 第四部分(第九章)对液质联用技术在药物代谢中的运用进行了综述。 This dissertation consisted of four sections. The first two sections elaborated thephytochemical investigation of the rhizomes Gymnadenia conopsea R. Br., methoddevelopment for rapid identifying and qutifying the chemical condtituent of thistibetant medicine, and the chemical fingerprint analysis of rhizomes of G. conopsea,Salviae miltiorrhiza and P. notoginseng. The third section studied the fragmentationmechanism of six alkaloids from Zanthoxylum nitidium and method development forrapid identifying varieties of alkaloids from the extract of this herbal medicine. Thefourth section reviewed HPLC- MS method in drug metabolism studies. The first section consisted of chapters 1, 2, 3. Chapter 1 elaborated the phytochemicalinvestigation of Gymnadenia conopsea R. Br. Four succinate derivative esters wereisolated from the methanol extract of the rhizomes of G. conopsea through repeatedcolumn chromatography on normal and reversed phase silica gel, their structures weredetermined by ESI-MS, 1D and 2D NMR evidence. They were firstly discoveredfrom this species. In chapter 2, a high-performance liquid chromatography.diodearray detection (HPLC-DAD) method has been firstly developed for quantitation oftwo characteristic constituents, adenosine and 4-hydroxybenzyl alcohol, from theextract of rhizomes of G. conopsea. All 10 samples of G. conopsea contained differentamount of adenosine and 4-hydroxybenzyl alcohol. Adenosine and the4-hydroxybenzyl alcohol can be applied in identification and quality control for theroots of G. conopsea. In chapter 3, a high-performance liquid chromatography.diodearray detection.tandem mass spectrometry (HPLC-DAD-MSn) method has been firstly developed for chemical fingerprint analysis of rhizomes of G. conopsea andrapid identification of major compounds in the fingerprints. Comparing the UV andMS spectra with those of authentic compounds, seven main peaks in the fingerprintswere identified as adenosine, 4-hydroxybenzyl alcohol, 4-hydroxybenzyl aldehyde,dactylorhin B, loroglossin, dactylorhin A and militarine. The Computer AidedSimilarity Evaluation System for Chromatographic Fingerprint of TraditionalChinese Medicine (CASES) was employed to evaluate the similarities of 10 samplesof the rhizomes of G. conopsea collected from Sichuan, Qinghai and Hebei provincesand Tibet autonomous region of China, and Nepal. These samples from differentsources had similar chemical fingerprints to each other. The second section consisted of chapters 4, 5, 6 and 7. In chapter 4,both thecharacteristic spectra of liposoluble tanshinones and aqueous-soluble salvianolic acidswere established by the electrospray ionization mass spectrometry (ESI MS)technique and the differences between standard and crude rhizomes of Salviaemiltiorrhiza Bge. from 5 sources were analyzed. The law of electrospray ion trap mass(ESI ITMS) of typical tanshinones and salvianolic acids is studied.The analysis of the chemical constituent of rhizomes of Salviae miltiorrhiza Bge. byliquid chromatography coupled with mass spectrum (LC/MS) technique wasestablished,and the distances among standard herb and crude herb from 5 sourceswere calculated by clustering analysis. According the DAD spectra and MS2 data,9tanshinones could be speculated. In chapter 5, the character spectra of total saponinsin P. notoginseng extracts were established by ESI ITMS and selective ion monitoring(SIM) technology. The law of notoginsenosides by ESI MS2 was studied. In chapter 6,the characteristic spectra of Compound Danshen Tablet established and compared byESI-MS and HPLC/DAD/MS, 6 known tanshinones and 3 saponins were speculated.In chapter 7, the advantage and disadvantage of the strategy, using the ESI ITMS andLC/MS techniques for study of characteristic spetra of danshen and Compound Danshen Tablet, were summerized. The third section (chapter 8) studied the fragmentation mechanism of six alkaloids,dihydronitidine, dihydrochelerythrine, 8-acetonyl dihydronitidine,8-acetonyldrochelerythrine, nitidine and 1,3-bis (8-dihydronitidinyl)-acetone, by ESIMSn. Tandem mass spectrometry experiments indicated that different substitutionsites of the methoxyl groups at C-9 and C-10 or at C-10 and C-11 determined thedifferent abundances of the MS2 fragmentation ions using the same collision energy.According to the different abundances of MS2 product ions, positional isomericbenzo[c] phenanthridine alkaloids can be differentiated. Moreover, ten constituents inthe crude alkaloids extract from the roots of Zanthoxylum nitidium were rapidlyidentified by high-performance liquid chromatography coupled with tandem massspectrometry (HPLC-MSn), through comparing the retention times and ESI MSn spectra with the authentic standards. The fourth section (chapter 9) is a review on HPLC-MS method development in drug metabolism studies.
Resumo:
To study the biotransformation of arctigenin, arctigenin was anaerobically incubated with Eubacterium sp. ARC-2 of human intestinal bacteria in vitro. Arctigenin formed a molecular ion [M-H](-) in negative ion mode. The arctigenin and its metabolites were investigated directly by the electrospray ionization tandem mass spectrometry ion trap and Fourier transform ion cyclotron resonance. Arctigenin was transformed to 4',4 ''-dihydroxylenterolactone by E sp. ARC-2 through 3 types of demethylation products.