226 resultados para paper electrophoresis

em Chinese Academy of Sciences Institutional Repositories Grid Portal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) has been abundantly used in the study of molecular interactions owing to such advantages as short analysis time, low sample size requirement, high separation efficiency, and flexible applications. The focus of this paper is to 2 review recent studies and advances (mainly from 1998 to now) in biomolecular interactions using CE. Five CE modes: zone migration CE, affinity CE, frontal analysis (FA), Hummel-Dreyer (HD) and vacancy peak (VP) are cited and compared. Quantitative aspects of the thermodynamics and kinetics of biomolecular interaction are reviewed. Several biomolecular binding systems, including protein-protein (polypeptide), protein-DNA (RNA), protein(polypeptide)-carbohydrate, protein-small molecule, DNA-small molecule, small molecule-small molecule, have been well characterized by CE. CE is shown to be a powerful tool for the determination of the binding parameters of various bioaffinity interactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Determination of arsenic species by large-volume field amplified stacking injection-capillary zone electrophoresis (LV-FASI-CZE) is reported in this paper. Whole column injection was employed. The optimum buffer pH for the separation of weak acids was discussed. It was found that the optimum buffer to analyze the stacked arsenate (As(V)), monomethylarsonate (MMA), and dimethylarsinate (DMA) was 25 mm phosphate at pH 6.5. However, the optimum buffer to analyze the concentrated arsenite (As(III)) was 20 mm phosphate - 10 mm borate at pH 9.28. The limits of detection of the method developed were 0.026 mg/L for As(III), 0.023 mg/L for As(V), 0.043 mg/L for MMA, and 0.018 mg/L for DMA. An enrichment factor of 34-100 for several arsenic species was obtained. In the end, this method was applied to determine the arsenic concentration in the environmental reference materials to show the usefulness of the method developed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper gives a capillary electrophoretic method for the separation of 15 urinary normal and modified nucleosides from cancer patients in less than 40 min. A 500 mmx50 mu m uncoated capillary column (437.5 mm to window) was used. The effects of the voltage and the sodium dodecyl sulfate (SDS) concentration in the buffer on the separation were studied. With reproducibilities of migration times better than 1.2% (R.S.D.) and determined concentrations better than 5-25%, depending on the concentrations of nucleosides in the urine, the analytical characteristics of the method were food. Using this developed method, the concentrations of 13 normal and modified nucleosides, extracted on a phenyl boronic acid affinity chromatography column, in 25 urines from patients of 14 kinds of cancer were determined. The levels (nmol/mol creatinine) of modified nucleosides in urines from cancer patients were increased as compared with those in normal urines. (C) 1998 Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we described a simple and rapid method, capillary electrophoresis with electrochemiluminescence (CE-ECL) detection using tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)), to simultaneously detect pethidine and methadone. Analytes were injected to separation capillary of 67.5 cm length (25 mu m i.d., 360 mu m o.d.) by electrokinetic injection for 10 s at 10 kV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a rapid, high efficient, sensitive and inexpensive approach based on a combination of simple ultrasonic extract and capillary electrophoresis (CE) separation with electrochemical detection (ED), is described to identify herbs by comparing their CE-ED profiles (namely, CE-ED electropherograms). The proposed method takes advantage of ultrasmall sample volume, low consumption of organic solvent, simple sample pretreatment and easy cleanup procedure. It was applied to analyze the CE-ED profiles of stems of herb Acanthopanax senticosus (Rupr. Et Maxim.) Harms from different sources and different parts (roots, rhizomes, stems and leaves) of this herb. By comparing peak number, peak height and peak height ratio, we found that the CE-ED profiles showed big differences for the herbs from the different sources and the different parts of this herb. In addition, the distribution of bioactive compounds (isofraxidin, rutin and chlorogenic acid) in the different parts of this herb and their content variations affected by the source were studied with the CE-ED method. Based on their own unique CE-ED profiles, these herbs from the different sources and the different parts of this herb could be easily distinguished. Therefore, the proposed approach could be used as a rapid, high efficient and sensitive method for the identification of herbal medicines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We developed an electrochemical detector on a hybrid chip for the determination of glucose in human plasma. The microchip system described in this paper consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate. The copper microelectrode is fabricated by selective electroless deposition. The fabrication of the decoupler is performed by platinum electrochemical deposition on the metal film formed by electroless deposition. Factors influencing the performance, including detection potential, separation field strength, and buffer concentration, were studied. The electrodes exhibited good stability and durability in the analytical procedures. Under optimized detection conditions, glucose responded linearly from 10 muM to 1 mM. Finally, glucose in human plasma from three healthy individuals and two diabetics was successfully determined, giving a good prospect for a new clinical diagnostic instrument.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fast analysis of ofloxacin and lidocaine, as bactericide and analgesic or anesthetics, is of clinic importance for understanding the patient's medical process. This paper presented a high throughput, simple analysis method of lidocaine and ofloxacin by capillary electrophoresis coupled with electrochemiluminescence (ECL) using porous etched joint. To shorten the analysis time and to improve the analytical performance, a capillary with 10 cm in length was used as the separation channel. The cyclic voltammograms of Ru(bpy)(3)(2+) with different capillary length at same field strength showed that the porous etched joint eliminated the effect of electrophoretic current on the ECL detection. Following micro total analysis systems (muTAS), some advantages of which this approach has, the fabrication of channel in chip was not needed. Compared with capillary electrophoresis with 40-cm-long capillary, the high sample throughput and low zone broadening may be the main advantage of the present system. Under optimal condition, the detection limits of lidocaine and ofloxacin based on peak height were 3.0 x 10(-8) and 5.0 x 10(-7) mot L-1 and a 60 h(-1) of sampling frequency was obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with Ru(bpy)(3)(2+) electrochemiluminescence. (ECL) detection system was established to the determination of contamination of banknotes with controlled drugs and a high efficiency on-column field-amplified sample stacking (FASS) technique was also optimized to increase the ECL intensity. The method was illustrated using heroin and cocaine, which are two typical and popular illicit drugs. Highest sample stacking was obtained when 0.01 mM acetic acid was chosen for sample dissolution with electrokinetical injection for 6 s at 17 kV. Under the optimized conditions: ECL detection at 1.2 V, separation voltage 10.0 kV, 20 mM phosphate-acetate (pH 7.2) as running buffer, 5 mM Ru(bpy)(3)(2+) with 50 mM phosphate-acetate (pH 7.2) in the detection cell, the standard curves were linear in the range of 7.50 x 10(-8) to 1.00 x 10(-5) M for heroin and 2.50 x 10(-7) to 1.00 x 10(-4) M for cocaine and detection limits of 50 nM for heroin and 60 nM for cocaine were achieved (S/N = 3), respectively. Relative standard derivations of the ECL intensity and the migration time were 3.50 and 0.51% for heroin and 4.44 and 0.12% for cocaine, respectively.The developed method was successfully applied to the determination of heroin and cocaine on illicit drug contaminated banknotes without any damage of the paper currency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aristolochic acids (AAs) are the main bioactive ingredients in the most of Aristolochia plants, which are used to make dietary supplements, slimming pills and Traditional Chinese Medicines (TCMs). Excessive ingestion of AAs can lead to serious nephropathy. Therefore, quantitative analysis and quality control for the plants containing AAs is of great importance. In this paper, capillary electrophoresis (CE) with electrochemical detection (ED) at a 33 mu m carbon fiber microdisk electrode (CFE) has been applied to detect AA-I and AA-II in Aristolochia plants. Under the optimum conditions: detection potential at 1.20 V, 2.0 x 10(-2) mol L-1 phosphate buffer solution (PBS) (pH 10.0), injection time 25 s at a height of 17 cm and separation voltage at 12.5 kV, the AA-I and AA-II were baseline separated within 5 min. Low detection limits for AA-I and AA-II were 4.0 x 10(-8) mol L-1 and 1.0 x 10(-7) mol L-1, respectively. Wide linear ranges were from 4.0 x 10(-8) mol L-1 to 1.9 x 10(-5) mol L-1 and 1.0 X 10(-7) mol L-1 to 5.0 x 10(-5) mol L-1 for AA-I and AA-II, respectively. The proposed method has been successfully applied to analyze AAs contents in plant extracts. The results indicated that the contents of AAs in each part of Aristolochia debilis Sieb. Et Zucc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fast analysis of ranitidine is of clinical importance in understanding its efficiency and a patient's treatment history. In this paper, a novel determination method for ranitidine based on capillary electrophoresis-electrochemiluminescence detection is described. The conditions affecting separation and detection were investigated in detail. End-column detection of ranitidine in 5 mM Ru(bpy)(3)(2+) solution at applied voltage of 1.20 V was performed. Favorable ECL intensity with higher column efficiency was achieved by electrokinetic injection for 10 s at 10 kV. The R.S.D. values of ECL intensity and migration time were 6.38 and 1.84% for 10(-4) M and 6.01 and 0.60% for 10(-5) M, respectively. A detection limit of 7 x 10(-8) M (S/N = 3) was achieved. The proposed method was applied satisfactorily to the determination of ranitidine in urine in 6 min.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Capillary electrophoresis (CE) with amperometric detection (AD) has been widely used in various fields of analytical science, especially in the pharmaceutical industry recently due to its high separation efficiency and low detection limit. The determination of active ingredients in Chinese herb medicines by CE-AD is of great importance in developing the researches on pharmacology of herbs, quantitative analysis and quality control. Analyses of the effective components in Chinese herb medicines and compound Chinese herb medicine by CE-AD are reviewed in this paper. In contrast with other analysis methods, the advantage of CE-AD is discussed. The development in analyses of traditional Chinese medicine (TCM) by CE-AD in future is mentioned.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an indium tin oxide (ITO) electrode-based Ru(bPY)(3)(2+) electrochemiluminecence (ECL) detector for a microchip capillary electrophoresis (CE). The microchip CE-ECL system described in this article consists of a poly(dimethylsiloxane) (PDMS) layer containing separation and injection channels and an electrode plate with an ITO electrode fabricated by a photolithographic method. The PDMS layer was reversibly bound to the ITO electrode plate, which greatly simplified the alignment of the separation channel with the working electrode and enhanced the photon-capturing efficiency. In our study, the high separation electric field had no significant influence on the ECL detector, and decouplers for isolating the separation electric field were not needed in the microchip CE-ECL system. The ITO electrodes employed in the experiments displayed good durability and stability in the analytical procedures. Proline was selected to perform the microchip device with a limit of detection of 1.2 muM (S/N = 3) and a linear range from 5 to 600 muM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we report the construction and application of a sol-gel derived carbon composite electrode (CCE) as an amperometric detector for capillary electrophoresis. The electrochemical properties were characterized and compared with those of conventional carbon fiber and carbon paste electrode (CPE). Experimental results show that peak-to-peak noise of CCE was about 20% of CPE and electrode capacitance was comparatively low. When applied to the detection of dopamine and epinephrine, the optimal detection potential for CCE was 0.1 V lower than CPE under the same separation conditions; CCE with diameter of 75 and 100 mum could achieve a low detection limit of 3.10(-8) and 6.10(-8) M for the detection of epinephrine, which approaching that of the 33-mum diameter carbon fiber electrode. Also, the linearity for epinephrine at CCE was more than two orders of magnitude, which was slightly wider than that of carbon fiber electrode. Applications to real sample analysis were tested by the determination of betahistine dihydrochloride in tablets and human urine. Using CCE with diameter less than or equal to100 mum as an amperometric detector after capillary electrophoresis separation, a low detection limit and a wide linear range combined with excellent reproducibility were obtained. This CCE possesses of many advantages, namely, convenience, ease of fabrication, low cost and high stability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describe a Ru(bpy)(3)(2+) based electrochemiluminescence (ECL) method to detect procyclidine in human urine following separation by capillary electrophoresis (CE). An ECL detection cell was designed for post-column addition of Ru(bpy)(3)(2+). Parameters affecting separation and detection were optimized, leading to a detection limit of 1 x 10(-9) mol/l in an on-capillary stacking mode. For application in urine, a cartridge packed with slightly acidic cation-exchange resin was used to eliminate the matrix effects of urine and improve the detection sensitivity. Extraction recovery was nearly 90%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new program to characterize polyethylene glycol-modified (PEGylated) proteins is outlined using capillary zone electrophoresis (CZE). PEGylated ribonuclease A and lysozyme were selected as examples. Five separation procedures were compared to select out the mixed buffer of acetonitrile-water (1:1, v/v) at pH 2.5 as the best to characterize the PEGylated proteins without sample pretreatment. Polyethylene oxide (PEO) with a high molecular mass of 8X10(6) was applied to rinse the capillary to form a dynamic coating which would decrease the undesirable proteins adsorbed to the inner wall of the silica. The electroosmotic flow (EOF) mobility of the five procedures was determined, respectively. It is found that acetonitrile is mainly responsible for the good resolution of PEGylated proteins with the help of PEO coating in the semi-aqueous system. The low EOF mobility and current in the semi-aqueous system might also have some responsibility for the high resolution. The semi-aqueous procedure described in this paper also demonstrates higher resolution of natural proteins than aqueous ones. (C) 2001 Elsevier Science B.V. All rights reserved.