Resumo:
A 32.1 W laser-diode-stack pumped acoustic-optic Q-switched Nd:YVO4 slab laser with hybrid resonator at 1064 nm was demonstrated with the pumping power of 112 W and repetition rate of 40 kHz, the pulse duration was 32.47 ns. The slope efficiency and optical-to-optical efficiency were 37 and 28.7%, respectively. At the repetition rate of 20 kHz and pumping power of 90 W, the average output power and pulse duration were 20.4 W and 20.43 ns, respectively. With the pumping power of 112 W, the beam quality M-2 factors in CW operation were measured to be 1.3 in stable direction and 1.6 in unstable direction.
Resumo:
A novel dual-slab laser with off-axis one-sided hybrid resonator is presented. The mode properties of the hybrid resonator are calculated using a fast Fourier transform method (FFT). The influence of wavefront distoration on the output beam quality is considered. Results indicate that the novel dual-slab laser is better than the normal dual-slab laser with off-axis one-sided hybrid resonator.
Resumo:
A diode stack end-pumped Nd:YVO4 slab laser at 1342 nm with near-diffraction-limited beam quality by using a hybrid resonator was presented. At a pump power of 139.5 W, laser power of 35.4 W was obtained with a conversion efficiency of 25.4% of the laser diode to laser output. The beam quality M-2 factors were measured to be 1.2 in the unstable direction and 1.3 in the stable direction at the output power of 29 W. (C) 2009 Optical Society of America
Resumo:
部分端面抽运的板条激光器是一种新型固体激光器.配合混合腔可以实现在大功率下保持高光束质量的激光振荡输出。谐振腔的腔镜倾斜是影响激光器输出特性的重要因素,快速傅里叶方法是一种快捷有效的计算方法,利用此方法模拟了腔镜倾斜对近场相位分布和远场光强分布的影响,并分析了光束质量的变化。理论分析表明,腔镜的小角度倾斜对近场相位影响较大,但对远场光强空间分布影响不大;随着倾斜角度不断增大,远场发散角和光束腰宽度也增大,光束质量虽然存在恶化的趋势,但光束质量因子肝值仍然较小,离轴非稳腔仍能保持高光束质量的输出。
Resumo:
为了获得大功率高光束质量的激光输出,利用自制的5bar激光二极管阵列堆作为抽运源,抽运光经波导整形系统整形后入射至晶体,采用柱面镜混合腔结构,对部分端面抽运的混合腔Nd∶YVO4板条激光器进行了实验研究。在最高抽运功率134W时,得到了38W的连续激光输出,斜效率44%,测得的两个方向的M2因子为1.56和1.78。实验结果表明,该激光器具有极佳的热效应,能够在高功率运转时保持高光束质量的激光输出,输入-输出功率曲线没有出现平顶或弯曲的迹象,该激光器仍有提升潜力,本结果有助于进一步提升该激光器的性能,实现更高功率的高光束质量激光输出。
Resumo:
部分端面抽运的混合腔板条激光器是一种新型的全固态激光器,采用这种结构,实现了高重复率调Q运转。在脉冲抽运情况下,1kHz运转时,得到脉宽4.6ns,单脉冲能量4.5mJ的激光输出。在连续抽运调Q输出情况下,5kHz高重复率运转时,获得了脉宽6ns,单脉冲能量3.1mJ的脉冲序列输出,平均功率超过15W;当重复率高达25kHz时,得到脉宽9.5ns,单脉冲能量1.2mJ的激光输出,平均功率达30W。实验结果表明,输出水平还有很大的提升空间。
Resumo:
激光器中激光介质采用板条状几何结构可以极大地降低它的热效应,但仍然需要进一步分析其影响,进而优化激光器效率。利用有限元分析方法分析了部分端面抽运的混合腔板条激光器中激光介质的热效应,计算的热透镜焦距与实测结果基本相符。分析了热效应对模式匹配的影响,分析结果对于优化激光器效率、改进谐振腔设计具有一定的参考价值。并在分析的基础上进行了混合腔实验,抽运功率为110 W时,获得连续输出激光功率41.5 W,光-光转换效率约38%,斜效率达58.8%,M2因子为非稳腔方向M2x=1.59,稳定腔方向M2y=1.55。
Resumo:
Partially end-pumped slab laser is an innovative solid state laser, namely InnoSlab. Combining the hybrid resonator with partially end-pumping, the output power can be scaled with high beam quality. In this paper, the output intensity distributions are simulated by coordinate transformation fast Fourier transform (FFT) algorithm, comparing the thermal lens influence. As the simulated curves showed, the output mode is still good when the thermal lens effect is strong, indicating the good thermal stability of InnoSlab laser. Such a new kind of laser can be designed and optimized on the base of this simulation.
Resumo:
报道了一种新型双板条离轴混合腔激光器。这种激光器结构通过改变传统的冷却方式和采用特殊的谐振腔设计,将使从第一块介质板条高温一侧出射的激光对称地进入另一块板条的低温一侧,从而可对由于温度分布不均匀造成的波面畸变进行一定程度的自校正,减少热效应的影响,可望提高激光器的输出功率和光束质量。利用快速傅里叶变换(FFT)对这种激光器的近场、远场以及相位等模场特性进行了数值计算。分析了波面畸变对输出光束质量的影响,并与常规双板条激光器进行了比较,结果表明这种新型双板条离轴混合腔激光器可以实现一定程度的波面畸变自补偿,
Resumo:
针对快速傅立叶方法在计算离轴非穗腔中存在的困难,在Sziklas和Siegman的波函数坐标变换理论的基础上稍作调整,计算了离轴混合腔的腔内光场分布、近场输出光强分布和远场光强分布,并与实验测得的光强分布曲线做了比较,得到了较为理想的理论模拟结果。同时,理论模拟结果也表明了利用离轴非稳腔能够得到高光束质量的激光输出。
Resumo:
对InnoSlab Laser用混合腔的输出光束质量问题从热透镜效应和腔镜的不对准两个方面的影响进行理论分析,并从远场光强分布、远场发散角、光腰半径、光束质量因子M2值和桶中功率曲线等几个角度进行了讨论,特别是离轴非稳腔方向上腔镜倾斜对光束质量的影响,利用M2值和PIB曲线两个参数共同评价非稳腔的光束质量,对目前并无统一标准的非稳腔光束质量评价问题提供了有意义的参考.
Resumo:
A planar waveguide laser operating in a negative branch unstable resonator is Q-switched by an acoustooptic mod latorin anew configuration, providing effective, high-speed switching. The laser using a 200-mu m Nd:YAG core, face pumped by 10 laser diode bars, has produced 100-W output in a good beam quality at 100-kHz pulse rate, and 4.5 mJ at lower frequency with 15-ns pulse duration.
Resumo:
A planar waveguide ring resonator was fabricated by organic-inorganic hybrid sol-gel materials; its sensitivity to ethanol vapor was experimentally investigated. It was found that dips in the transmission spectrum of the device shifted to longer wavelengths with increasing the ethanol concentration, and its sensitivity showed a linear relation with the ethanol concentration, showing a coefficient of 1.13 pm/ppm. In addition, the transmission loss of the ring resonator decreased with increasing the ethanol concentration. The measured characteristics suggest that the device may be considered as one of the candidates of alcohol vapor sensors. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
The stiffness behaviour of injection moulded short glass fibre/impact modifier/polypropylene hybrid composites has been investigated in this work by theoretical predictions and experiments. Predictions from the self-consistent method were found to be in good agreement with test results for the impact modifier/polypropylene blends. By taking into account of the fibre orientation distributions in the skin and core layers, the values of Young's modulus for the skin and core layers were predicted by employing Eshelby's equivalent inclusion method and the average induced strain approach. The prediction of the values of Young's modulus for the whole sample was obtained by applying the simple mixture theory of laminated composites to the predicted results for the skin and core layers. Good correlation between predicted and experimental Young's modulus values were found.
Resumo:
In this paper, construction of hybrid device by integrating nanowires with F1-ATPase motors is described. The nickel nanowires and multi-segment nanowires, including gold and nickel, were fabricated by electrochemical deposition in nanoporous templates. The nickel nanowires functionalized by biotinylated peptide can be assembled directly onto F1-ATPase motors to act as the propellers. If the multicomponent nanowires, including gold and nickel, were selectively functionalized by the thiol group modified ssDNA and the synthetic peptide, respectively, the biotinylated F1- ATPase motors can be attached to the biotinylated peptide on nickel segment of the nanowires. Then, the multi-component nanowires can also be used as the propellers, and one may observe the rotations of the multi-component nanowires driven by F1-ATPase motors. Therefore, introduction of multiple segments along the length of a nanowire can lead to a variety of multiple chemical functionalities, which can be selectively bound to cells and special biomolecules. This method provides an insight for the construction of other hybrid devices with its controlling arrangement of different biomolecule on designed nanometer scale structures.